scholarly journals Behavior of horizontal sub-surface flow wetlands as an alternative for the wastewater treatment contaminated with florfenicol

2020 ◽  
Vol 23 (1) ◽  
Author(s):  
Diana Catalina Rodriguez ◽  
Mary A Cardona ◽  
Gustavo Peñuela

In recent years, the increase in the use and production of antibiotics for the protection of animals has been associated not only with human health problems due to bacterial resistance, but also with environmental problems, which have led to the deterioration of the water resources, since a large part of these are discharged into the environment without any type of treatment. This situation has highlighted the fact that a large part of the antibiotics are not efficiently removed in conventional wastewater treatment plants, being necessary to implement efficient and low-cost treatment alternatives. The evaluation of the removal of the antibiotic florfenicol was carried out using pilot horizontal subsurface flow wetlands, with a hydraulic retention time of 4.2 d, planted with macrophytes (Phragmites australis) and using concentrations of 10, 15, 20 and 25 mg/L of florfenicol. It was concluded that the removal of the antibiotic and the COD was decreasing over time, with a maximum removal percentage of 77.9% of florfenicol and 85.2% of COD during the first days of exposure. The results found allowed to demonstrate that florfenicol was not retained in the granular material of the wetlands, even in the macrophytes and that the predominant removal mechanism was biological degradation.

Author(s):  
Carlos Eduardo Zacarkim ◽  
Luciano Caetano De Oliveira ◽  
Nayara Symanski ◽  
Fernando Rodolfo Espinoza Quinõnes ◽  
Soraya Moreno Palácio ◽  
...  

The study was based on a surface flow wetland system, using the macrophyte Eicchornia crassipes. The use of wetlands as an alternative in the wastewater treatment process has been employed due to the handling and simple technology, addition to the low cost compared to conventional systems. Three hydraulic retention times, they are 4, 6 and 8 days were analyzed. In general the system showed significant results in relation to removals of nutrients for all TRH reviews, where the hydraulic retention time of 6 days achieved the best performance. The proposed system achieved 79.91% reductions for COD, 83.51% of Total Phosphorus, Total Nitrogen 67.93%, 87.7% chromium and 52% Sulfur.


2008 ◽  
Vol 3 (1) ◽  
Author(s):  
Luchien Luning ◽  
Paul Roeleveld ◽  
Victor W.M. Claessen

In recent years new technologies have been developed to improve the biological degradation of sewage sludge by anaerobic digestion. The paper describes the results of a demonstration of ultrasonic disintegration on the Dutch Wastewater Treatment Plant (WWTP) Land van Cuijk. The effect on the degradation of organic matter is presented, together with the effect on the dewatering characteristics. Recommendations are presented for establishing research conditions in which the effect of sludge disintegration can be determined in a more direct way that is less sensitive to changing conditions in the operation of the WWTP. These recommendations have been implemented in the ongoing research in the Netherlands supported by the National Institute for wastewater research (STOWA).


REAKTOR ◽  
2019 ◽  
Vol 19 (1) ◽  
pp. 18-25
Author(s):  
Ariani Dwi Astuti ◽  
Dewi Intania Ayu

Tofu which is made by grinding soy bean, generates huge amount of wastewater and thus considered as one of the most polluted food-industrial effluent owing to its high values of organic contents. The small industries of tofu preparation process release the wastewater directly into the water body without being treated first. Prior to discharge this wastewater into the waterbody, the wastewater must be treated to reduce the possibility of negative impact and the contamination of the waterbody. For these small industries, the best alternative of wastewater treatment is one which has the following criteria: easy in operation, low cost operation, low volumes of sludge produced, and can be used in high concentration wastewater. In this research, bioreactor anaerobic-aerobic with media bioball is used. The highest removal efficiency of COD took place in anaerobic zones. Bioreactors were operated with the variations of retention time at 24 hours, 18 hours, and 12 hours. The COD removal efficiency for Hydraulic Retention Time (HRT) of 24 hours, 18 hours and 12 hours were found 90.3% (organic loading rate is 15.1 kg COD/m3.day), 84.4% and 76.3% respectively. The experiment showed that the longer of the hydraulic retention time (HRT), the higher the removal efficiency could be achieved. These occurred because a longer HRT will extend the contact time between wastewater and microorganisms attached. Therefore, microorganisms have a longer time to degrade organic matter in wastewater. Although the removal efficiency in these three-HRT was found high, the effluent of the reactor was still above the effluent standard based on regulation of Ministry of Environmental Permen LH No. 5/2014. Kinetics using Eckenfelder Equation results R2 equal to 0.9991, n equal to 0.293 and K equivalent to 7.3577 mg/L. Keywords: tofu wastewater, anaerobe, aerobe, bioball, wastewater, treatment, attached growth


2000 ◽  
Vol 41 (1) ◽  
pp. 57-63 ◽  
Author(s):  
S. Vandaele ◽  
C. Thoeye ◽  
B. Van Eygen ◽  
G. De Gueldre

In Flanders (Belgium) an estimated 15% of the population will never be connected to a central wastewater treatment plant (WWTP). Small WWTPs can be a valuable option. Aquafin bases the decision to build SWWTPs on a drainage area study. To realise an accelerated construction the process choice is made accordingly to a standard matrix, which represents the different technologies in function of the size and the effluent consents. A pilot scale constructed two-stage reed bed is used to optimise the concept of the reed beds. The concept consists of a primary clarifier, two parallel vertical flow reed beds followed by a sub-surface flow reed bed. The removal efficiency of organic pollutants is high (COD: 89%, BOD: 98%). Phosphorus removal is high at the start-up but diminishes throughout the testing period (from 100% to 71% retention after 7 months). Nitrogen removal amounts to 53% on average. Nitrification is complete in summer. Denitrification appears to be the limiting factor. In autumn leakage of nitrogen is assumed. Removal efficiency of pathogens amounts to almost 99%. Clogging forms a substantial constraint of the vertical flow reed bed. Problems appear to be related with presettlement, feed interval and geotextile.


2001 ◽  
Vol 44 (1) ◽  
pp. 105-112 ◽  
Author(s):  
M. Burde ◽  
F. Rolf ◽  
F. Grabowski

The absence of large rivers with rather high niveau of self purifying effect in parts of east Germany leads to a discharging of the effluent of wastewater treatment plants into the groundwater in many cases. One useful consequence is the idea of realisation of decentralised measures and concepts in urban water resources management concerning municipal wastewater as well as rainfall, precipitation. At the same time, only the upper soil zone - a few decimetres - is water - saturated and thus discharge effective, even when extreme rainfall takes place. Underneath, however, there generally exists an unsaturated soil zone, which is up to now a rather unexplored retardation element of the hydrologic- and substrate-cycle. Nutrient removal in small wastewater treatment plants that are emptying into ground waters is often beneficial. The presented studies optimised an inexpensive method of subsequent enhanced wastewater treatment. The developed reactor is similar to a concentrated subsoil passage. The fixed bed reactor is divided in two sections to achieve aerobic and anoxic conditions for nitrification/denitrification processes. To enhance phosphorus removal, ferrous particles are put into the aerobic zone. Two series of column tests were carried out and a technical pilot plant was built to verify the efficiency of the process. The results show that this method can be implemented successfully.


2005 ◽  
Vol 52 (10-11) ◽  
pp. 255-263 ◽  
Author(s):  
J. Chauzy ◽  
S. Graja ◽  
F. Gerardin ◽  
D. Crétenot ◽  
L. Patria ◽  
...  

In many cases, reducing sludge production could be the solution for wastewater treatment plants (WWTP) that here difficulty evacuating the residuals of wastewater treatment. The aim of this study was to test the possibility of minimising the excess sludge production by coupling a thermal hydrolysis stage and an anaerobic digestion with a very short HRT. The tests were carried out on a 2,500 p.e. pilot plant installed on a recycling loop between the clarifier and the actived sludge basin. The line equipped with the full scale pilot plant produced 38% TSS less than the control line during a 10 week period. Moreover, the rapid anaerobic digestion removed, on average, more than 50% of the total COD load with a hydraulic retention time (HRT) of 3 days. Lastly, the dryness of the remaining excess sludge, sanitised by the thermal hydrolysis, was more than 35% with an industrial centrifuge. This combination of thermal hydrolysis and rapid anaerobic digestion equally permits a significant gain of compactness compared to traditional anaerobic digesters.


2021 ◽  
Vol 11 (16) ◽  
pp. 7454
Author(s):  
Ke Li ◽  
Jingyao Qi ◽  
Fuguo Zhang ◽  
Nicholas Miwornunyuie ◽  
Paulette Serwaa Amaniampong ◽  
...  

CWMFC is a novel technology that has been used for almost a decade for concurrent wastewater treatment and electricity generation in varying scopes of domestic, municipal, and industrial applications since its implementation in 2012. Its advantage of low-cost enhanced wastewater treatment and sustainable bioelectricity generation has gained considerable attention. Nevertheless, the overall efficiency of this novel technology is inclined by several operating factors and configuration strands, such as pH, sewage composition, organic loading, electrode material, filter media, electrogens, hydraulic retention time, and macrophytes. Here, we investigate the effect of the wetland plant component on the overall performance of CWMFCs. The macrophyte’s involvement in the oxygen input, nutrient uptake, and direct degradation of pollutants for the required treatment effect and bioelectricity production are discussed in more detail. The review identifies and compares planted and unplanted CWMFC with their efficiency on COD removal and electricity generation based on previous and recent studies.


1996 ◽  
Vol 34 (5-6) ◽  
pp. 393-401 ◽  
Author(s):  
Wolf Merkel ◽  
Alexander Schwarz ◽  
Sebastian Fritz ◽  
Matthias Reuss ◽  
Karlheinz Krauth

Approaches to mathematical modelling of anaerobic digestion and criteria for reactor design in anaerobic wastewater treatment are based on biological degradation kinetics. Whatever type of kinetics is used, the crucial problem always is reliable parameter estimation. For Monod-type kinetics a concept based on batch and fed-batch techniques is presented, which allows accurate estimation of kinetic parameters Vmax and KS in short-time experiments. Following the method of Optimal Experimental Design, sensitivity analysis is applied to design fed-batch experiments. The paper presents the methodology and results for the anaerobic degradation of acetic acid and discusses further implications of the experimental strategy.


2020 ◽  
Vol 10 (3) ◽  
pp. 78-83
Author(s):  
Aysegul Pala ◽  
Ecem Kocabıyık ◽  
Gunes Kursun

The aim of this study is technical and statistical evaluation of wastewater treatment plants existing at the holiday resorts in areas surrounding Izmir City. The study was carried out in the time period from August to September 2018. Within the scope of the study, 150 holiday resorts were investigated and listed. The necessary permissions were obtained and the treatment plants were visited at their current locations. Most of the wastewater treatment plants are embedded in the ground and are referred to as package treatment systems. They are used at holiday resorts for many reasons, such as smell and noise control. Many parameters have been considered within the scope of the study, such as installed power of the plant, influent wastewater flow and pollutant concentration, the properties of the sludge, sludge disposal methods, effluent wastewater parameters, the method and location of effluent water discharge, operation period of the wastewater treatment plant. As a result of this study, it has been found that the low cost package treatment systems were generally preferred. The systems that required most energy were the blowers. In order to provide clean and smooth environment, the use of central wastewater treatment plants is more suitable than the use of package treatment systems


Sign in / Sign up

Export Citation Format

Share Document