scholarly journals PERILAKU PUNCHING SHEAR PADA HUBUNGAN KOLOM BULAT DENGAN FLAT SLAB AKIBAT BEBAN TEKAN AKSIAL

2019 ◽  
Vol 1 (1) ◽  
pp. 1-14
Author(s):  
Muhammad Zardi

The aim of the tests was to investigate the influence of concrete strength, the eccentricity of the column and the use of shear reinforcement in flat slabs on punching shear. The research specimens are 8 units of flat slabs. Flat slab size 1400 x 1400 mm2 with thickness of 120 mm. Flat slabs were connected with circular column with dimension 225 mm  of diameter and 200 mm of height. Flat slabs were made in to 2 variations of concrete strength, e.i. 30 MPa and 60 MPa, 2 variations of shear reinforcement, e.i. without shear reinforcement and with shear reinforcement and 2 variations of eccentricity that, e.i. without eccentricity and with eccentricity. Each treatment has 1 specimen. Each specimen has 6 cylinder specimens. Cylinder specimens used as a concrete strength control for main specimen (flat slab). The tests showed that the concrete strength had a strong influence on punching shear strength. This is shown by capacity increase of 42.78%; 54.00%; 46.59% and 0.02%. The value is ratio between the maximum load of the specimens with 60 MPa and 30 MPa at the same eccentricity and the same shear reinforcement. The eccentricity of column reduce the capacity of punching shear. This is shown by 3 specimens decrease in capacity of 3.70%; 36.75% and 7.30%. Only 1 specimen that increase in capacity of 9.27%. The value is ratio between the maximum load of the specimens with 40 mm eccentricity and 0 mm eccentricity at the same compressive strenght and the same shear reinforcement. The use of shear reinforcement does not always increase the punching shear capacity. There are 2 observations that increased capacity (52.07% and 65.37% at the centric load) and 2 observations decreased capacity (0.12% and 4.92% at the eccentric load). The value is ratio between the maximum load on the specimens using shear reinforcement with the specimens that do not use shear reinforcement at the same compressive strenght and the same eccentricity.The use of shear reinforcement increase punching shear capacity of flat slab at the centric load condition. The use of shear reinforcement decrease punching shear capacity of flat slab at the eccentric load condition.

This research targets to maximize the ductility and strength of the reinforced concrete flat slabs. However, to be efficient, the shear reinforcement must be anchored well in the tension and compression zones of the slab. The test results on the slab-column connection models which provided with shear reinforcement are introduced in this study. The benefits of using shear reinforcement are to reduce the slab thickness, and to minimize both the cost and the total weight of the structure. Twelve flat slab specimens have been tested to study the effect of different types of steel RFT on the punching shear of the flat slab. The experimental parameters include no shear reinforcement which study the advantage of using tension RFT ONLY against punching shear, no shear reinforcement which study the advantage of using compression RFT against punching shear, shear RFT (Vertical Stirrups) which study the effect of using shear RFT with constant distribution 0.5d, and a new distribution of shear stirrups which study the effect of using new different width & spacing of vertical stirrups. The twelve specimens were loaded with concentrated load at the mid span until failure. The general behavior of the deformation of the tested slab specimens was examined and recorded (cracking, deflection, and strain in both steel and concrete). A comparison established between the experimental and the numericaltheoretical results obtained from applying the punching shear strength formula given in design codes, and finite element modeling analysis; ABAQUS 2017 software package was used for this analysis. A total of six building codes were examined with regard to their provisions concerning the punching shear. A comparison had been made between the research test results and the codes equations to improve the methods of the analysis about the flat slabs. This study aimed to improve the punching shear capacity of flat slab which leads to more accurate results compared with the codes predictions. To achieve this aim, an experimental and numerical study was carried out for this investigation.


Author(s):  
Fatma M. Eid ◽  
Tayel Magdy ◽  
Ebada Ahmed

Punching shear failure is a major problem encountered in the design of reinforced concrete flat slabs. The utilization of shear reinforcement via shear studs or other means has become a choice for improving the punching shear capacity. In this study, a new alternative of reinforcement modalities were tested and demonstrated the effect of self-compact concrete on the punching shear capacity, beside that compared between the difference codes to identify the suitable one for determining the position of critical section of punching shear. Nevertheless, in this investigation, the proposed reinforcement system is examined for interior columns only. An experimental work consisting of six specimens: five of them were cast with normal reinforced concrete and one was cast with self-compact strength concrete. The obtained results indicate that the proposed shear reinforcement system has a positive effect in the enhancement of the punching shear capacity of interior slab–column connection of self-compact strength concrete.


2021 ◽  
Vol 1203 (2) ◽  
pp. 022108
Author(s):  
Daniel Čereš ◽  
Katarína Gajdošová

Abstract The main reasons for strengthening flat slabs are the change of the use of a building, increase in the value of loads, degradation of the concrete cover layer, or insufficient reinforcement. This paper is focused on the assessment of punching shear capacity of the strengthened flat slabs without shear reinforcement. One of the possibilities how to enhance punching shear capacity is the addition of reinforced concrete topping. The main goal of this paper is to compare the possibilities for calculation of the increase in the punching shear capacity by investigation of the influence of different thicknesses of concrete toppings and different reinforcement ratio. A reference specimen is represented by a fragment of a flat slab with the thickness of h = 200 mm supported by circular column with the diameter of 250 mm. Three different thicknesses (50 mm, 100 mm, 150 mm) of concrete toppings were considered together with three different reinforcement ratios for each thickness of concrete overlay. Theoretical predictions of the punching shear resistance of flat slabs were evaluated by design guidelines according to the relevant standards: Eurocode 2 (EN 1992-1-1), Model Code 2010 and draft of the second generation of Eurocode 2 (prEN 1992-1-1). The differences in the influence of reinforcement ratio are significant. In Model Code 2010 the reinforcement ratio in concrete topping was considered in equation of moment of resistance. This is unlike in both of the mentioned Eurocodes, where the reinforcement ratio was assumed as a geometric average value of the original reinforcement ratio in the slab before strengthening and of the reinforcement ratio of concrete topping. All the predicted theoretical calculations are based on the perfect connection and bond between the original and new layer of concrete. These predictions should be verified by experimental investigation, which is going to be prepared shortly. By the additional increase in the thickness of concrete topping or in the amount of added reinforcement the attention should be payed to the limitation of the punching shear resistance by the value of the maximum punching shear resistance in the compression concrete strut.


2021 ◽  
Vol 16 (1) ◽  
pp. 52-57
Author(s):  
Petra Bujňáková ◽  
Jakub Mečár

AbstractSeveral types of punching shear reinforcements are available for increase of the maximum resistance against punching shear failure of flat slabs. Conventional punching shear reinforcement in form of stirrups or double headed studs are in use for decades. They are well known due to their simplicity and good performance. A new type of punching reinforcement has been developed for the case, where the flat slab exposed to extreme load and resistance of conventional type of punching shear reinforcement is not sufficient. Another designs point out that new construction system can reduce the amount of CO2. This paper presents some results of parametric study focused on design of the flat slab using different types of punching shear reinforcement and considering the concrete consumption.


2013 ◽  
Vol 4 (4) ◽  
pp. 259-280 ◽  
Author(s):  
Mehrafarid Ghoreishi ◽  
Ashutosh Bagchi ◽  
Mohamed Sultan

There are a number of benefits associated with two-way concrete flat slab construction for office buildings, parking garages and apartments - for example, reduced formwork, prompt erection, flexibility of partitions, and minimal increase in story heights. However, concrete flat slabs could be quite vulnerable to punching shear failure in the event of a fire. The objective of the present article is to provide a state of the art review of the existing research and the issues associated with concrete flat slabs in fire and elevated temperature. There are a number of experimental and analytical studies on the punching shear behavior of concrete flat slabs in ambient conditions, available in the literature. Based on these studies, it is found that punching shear capacity in ambient condition is affected by many factors, which may not remain constant during a fire exposure. Only a limited number of studies on concrete flat slabs for punching shear failure in fire are available. This paper reviews the available experimental and analytical studies, standards and codes to address the research gap in estimating of punching shear strength of concrete flat slab-column connections without shear reinforcement.


2018 ◽  
Vol 7 (2.20) ◽  
pp. 321
Author(s):  
N Girish ◽  
N Lingeshwaran

Punching shear failure is a brittle failure and it is one of the most important types of failure to be considered while designing a reinforced concrete flat slab. This paper aims to study the performance of reinforced concrete flat slabs equipped with different punching shear reinforcement parameters. Three flat slab specimens were cast where two specimens contain punching shear reinforcement in the form of shear stirrups and structural shearbands. The test specimens have length and width of 1000mm and thickness of 185mm for the slabs. The slabs are connected to a column at the center with length and breadth of 300mm and a depth of 700mm. The test specimens were supported by steel plates with length and breadth of 150mm and a thickness of 25mm at the four corners of the slab. The test specimens are loaded on the column face at the top. The deflection, strain and crack pattern were observed and recorded.   


Polymers ◽  
2020 ◽  
Vol 12 (3) ◽  
pp. 685 ◽  
Author(s):  
Osama Ahmed Mohamed ◽  
Manish Kewalramani ◽  
Rania Khattab

Reinforced concrete flat slabs or flat plates continue to be among the most popular floor systems due to speed of construction and inherent flexibility it offers in relation to locations of partitions. However, flat slab/plate floor systems that are deficient in two-way shear strength are susceptible to brittle failure at a slab–column junction that may propagate and lead to progressive collapse of a larger segment of the structural system. Deficiency in two-way shear strength may be due to design/construction errors, material under-strength, or overload. Fiber reinforced polymer (FRP) composite laminates in the form of sheets and/or strips are used in structurally deficient flat slab systems to enhance the two-way shear capacity, flexural strength, stiffness, and ductility. Glass FRP (GFRP) has been used successfully but carbon FRP (CFRP) sheets/strips/laminates are more commonly used as a practical alternative to other expensive and/or challenging methods such column enlargement. This article reviews the literature on the methodology and effectiveness of utilizing FRP sheets/strips and laminates at the column/slab intersection to enhance punching shear strength of flat slabs.


2021 ◽  
Vol 28 (3) ◽  
pp. 35-74
Author(s):  
Mustafa Al-Mashaykhi ◽  
Belal Alsubari ◽  
Mazin Abdulrahman ◽  
Aayat Hussein

This research is devoted to investigating experimentally the punching shear strength of reactive powder concrete slabs under monotonic loading. All slabs have the same flexural reinforcement and same dimensions (1000mm length,600mm width,50mm thickness). The experimental program includes casting and testing of sixteen slabs tested under monotonic loading. The major parameters adopted in the current research include the shape of column (circle, square), column size (twocolumn sizes), number of columns (one, two), and the distance between two columns (3d,5d,7d). Results showed that, the slabs with circular column sections have slightly higher ultimate load than those with square column sections. An increasing column area increases the load of punching shear failure. It was found that the ultimate failure load for slabs with two columns is greater than the slabs with one column. Related to the effect of distance between the two columns for monotonic, it was found that the slabs maximum load reaches the maximum value at distance between the two columns equal to(7d) for a circular section with a diameter of 85mm and 113mm and square section with dimensions of (100*100)mm. While the maximum failure load reaches the maximum value when the distance between two columns (d) for a square section with the dimension of (75*75)mm. Related to the crack patterns, it was noticed that for slabs with larger columns sections with the distance between columns equal to 7d, the failure zone extended (in a large direction) to the slab sides.


2017 ◽  
Vol 259 ◽  
pp. 232-237
Author(s):  
Lucia Majtánová ◽  
Jaroslav Halvonik ◽  
Ján Hanzel

Two ways how to determine maximum punching resistance of flat slabs with shear reinforcement are currently used. The first way is verification of the concrete strut capacity at the column periphery defined as VRd,max. The second limit is defined as kmax multiple of the punching shear resistance without shear reinforcement VRd,c. The values of kmax are proposed usually in between 1.4 and 2.0. Results of the experimental tests are presented in the paper that were focused on above mentioned limits, whether failure of the struts can precede any other form of punching failure that is limited by kmax*VRd,c. Two experimental slab samples reinforced with high amount of shear reinforcement that increased punching capacity above capacity of the concrete struts were tested together with two slab samples cast without shear reinforcement. Comparison has shown that punching resistance of flat slab with shear reinforcement has been 1.7 times higher than resistance without shear reinforcement. While some standards allow for use kmax value of 1.9 in this case. This indicates that limits based only on the kmax factors may overestimate actual maximum punching shear resistance.