Specific Determination of PAH and Its N-Acetyl Metabolite by HPLC Increases the Accuracy and Precision of PAH Clearance Measurements

Renal Failure ◽  
1998 ◽  
Vol 20 (2) ◽  
pp. 311-317 ◽  
Author(s):  
Laurent A. Decosterd ◽  
Natacha Bélaz ◽  
Monique Appenzeller ◽  
Ali Maghraoui ◽  
Philippe Rousso ◽  
...  
1984 ◽  
Vol 223 (2) ◽  
pp. 455-459 ◽  
Author(s):  
M Vermeir ◽  
F Vanstapel ◽  
N Blanckaert

A radioassay for specific determination of the rates of UDP-glucuronic acid-dependent conversion of bilirubin into the two isomeric (C-8, C-12) bilirubin monoglucuronides and bilirubin diglucuronide is described and illustrated by its application to rat liver microsomes. The method is based on measurement of the relative amounts of radiolabel in unesterified bilirubin and its mono- and di-esterified reaction products after incubation with [14C]bilirubin as substrate. This analysis is performed by the alkaline-methanolysis procedure, combined with one of two t.l.c. systems developed in order to enhance the sensitivity, accuracy and precision of the radioassay. Results for rates of total bilirubin glucuronide formation obtained with the new assay and the standard enzyme assay based on the ethyl anthranilate diazo-method were identical. However, the sensitivity of the latter technique is approx. 10-fold lower than that of the radioassay.


2020 ◽  
Vol 23 (10) ◽  
pp. 1010-1022
Author(s):  
Emrah Dural

Aim and scope: Due to the serious toxicological risks and their widespread use, quantitative determination of phthalates in cosmetic products have importance for public health. The aim of this study was to develop a validated simple, rapid and reliable high-performance liquid chromatography (HPLC) method for the determination of phthalates which are; dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), di-n-butyl phthalate (DBP), di(2- ethylhexyl) phthalate (DEHP), in cosmetic products and to investigate these phthalate (PHT) levels in 48 cosmetic products marketing in Sivas, Turkey. Materials and Methods: Separation was achieved by a reverse-phase ACE-5 C18 column (4.6 x 250 mm, 5.0 μm). As the mobile phase, 5 mM KH2PO4 and acetonitrile were used gradiently at 1.5 ml min-1. All PHT esters were detected at 230 nm and the run time was taking 21 minutes. Results: This method showed the high sensitivity value the limit of quantification (LOQ) values for which are below 0.64 μg mL-1 of all phthalates. Method linearity was ≥0.999 (r2). Accuracy and precision values of all phthalates were calculated between (-6.5) and 6.6 (RE%) and ≤6.2 (RSD%), respectively. Average recovery was between 94.8% and 99.6%. Forty-eight samples used for both babies and adults were successfully analyzed by the developed method. Results have shown that, DMP (340.7 μg mL-1 ±323.7), DEP (1852.1 μg mL-1 ± 2192.0), and DBP (691.3 μg mL-1 ± 1378.5) were used highly in nail polish, fragrance and cream products, respectively. Conclusion: Phthalate esters, which are mostly detected in the content of fragrance, cream and nail polish products and our research in general, are DEP (1852.1 μg mL-1 ± 2192.0), DBP (691.3 μg mL-1 ± 1378.5) and DMP (340.7 μg mL-1 ±323.7), respectively. Phthalates were found in the content of all 48 cosmetic products examined, and the most detected phthalates in general average were DEP (581.7 μg mL-1 + 1405.2) with a rate of 79.2%. The unexpectedly high phthalate content in the examined cosmetic products revealed a great risk of these products on human health. The developed method is a simple, sensitive, reliable and economical alternative for the determination of phthalates in the content of cosmetic products, it can be used to identify phthalate esters in different products after some modifications.


2020 ◽  
Vol 16 (6) ◽  
pp. 671-689
Author(s):  
Marcin Gackowski ◽  
Marcin Koba ◽  
Katarzyna Mądra-Gackowska ◽  
Piotr Kośliński ◽  
Stefan Kruszewski

At present, no one can imagine drug development, marketing and post-marketing without rigorous quality control at each stage. Only modern, selective, accurate and precise analytical methods for determination of active compounds, their degradation products and stability studies are able to assure the appropriate amount and purity of drugs administered every day to millions of patients all over the world. For routine control of drugs simple, economic, rapid and reliable methods are desirable. The major focus of current scrutiny is placed on high-performance thin layer chromatography and derivative spectrophotometry methods, which fulfill routine drug estimation’s expectations [1-4]. The present paper reveals state-of-the-art and possible applications of those methods in pharmaceutical analysis between 2010 and 2018. The review shows advantages of high-performance thin layer chromatography and derivative spectrophotometry, including accuracy and precision comparable to more expensive and time-consuming methods as well as additional fields of possible applications, which contribute to resolving many analytical problems in everyday laboratory practice.


2019 ◽  
Vol 15 (6) ◽  
pp. 635-641
Author(s):  
Nadia M. Mostafa ◽  
Ghada M. Elsayed ◽  
Nagiba Y. Hassan ◽  
Dina A. El Mously

Background:The concept of green analytical chemistry prevails due to the growing environmental pollution.Objective:Our attempts are to develop simple and eco-friendly method which is non-harmful to the environment by producing minimal waste. In this context, a green liquid chromatographic method was applied for the simultaneous determination of chlorpheniramine maleate, pseudoephedrine hydrochloride and propyphenazone in their combined dosage form.Methods:Separation was carried out using X select HSS RP C18 analytical column (250 × 4.6 mm, 5μm) using methanol - 0.02 M phosphate buffer pH 3 - triethylamine (60:40: 0.1, by volume) as a mobile phase. The separated peaks were detected at 215 nm at a flow rate 1.0 mL/min.Results:Quantification was done over the concentration ranges of 1-25 µg/mL for chlorpheniramine maleate, 5-35 µg/mL for pseudoephedrine hydrochloride and 10-120 µg/mL for propyphenazone. The suggested method was validated with regard to linearity, accuracy and precision according to the International Conference on Harmonization guidelines with good results.Conclusion:It could be used as a safer alternative for routine analysis of the mentioned drugs in quality control laboratories.


2020 ◽  
Vol 16 ◽  
Author(s):  
Aykut Kul ◽  
Murat Ozdemir ◽  
Selma Ozilhan ◽  
Olcay Sagirli

Background: Buprenorphine is quite common in the illicit market. Buprenorphine-containing drugs abuse is frequently encountered in patients. The analysis methods used to determine the abuse of buprenorphine and norbuprenorphine are important for forensic science. Buprenorphine is metabolized to norbuprenorphine by the liver. Objective: Therefore, the determination of buprenorphine and norbuprenorphine in urine is one of the methods to determine the abuse of buprenorphine. Methods: In this study, we have developed a precise, simple, and rapid ultra-performance liquid chromatographytandem mass spectrometer method for the determination of buprenorphine and norbuprenorphine simultaneously. Results: The developed method was validated in terms of selectivity and linearity, which was in the range of 9–1800 ng/mL for both buprenorphine and norbuprenorphine. The intra-assay and inter-assay accuracy and precision were found within acceptable limits of the EMA guideline. Lower limits of quantitation were 9 ng/mL for both buprenorphine and norbuprenorphine. Conclusion: The developed method was successfully applied for the determination of both analytes in the proficiency testing samples.


Molecules ◽  
2021 ◽  
Vol 26 (14) ◽  
pp. 4357
Author(s):  
Waritda Pookmanee ◽  
Siriwan Thongthip ◽  
Jeeranut Tankanitlert ◽  
Mathirut Mungthin ◽  
Chonlaphat Sukasem ◽  
...  

The method for the determination of primaquine (PQ) and 5,6-orthoquinone primaquine (5,6-PQ), the representative marker for PQ active metabolites, via CYP2D6 in human plasma and urine has been validated. All samples were extracted using acetonitrile for protein precipitation and analyzed using the ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) system. Chromatography separation was carried out using a Hypersil GOLDTM aQ C18 column (100 × 2.1 mm, particle size 1.9 μm) with a C18 guard column (4 × 3 mm) flowed with an isocratic mode of methanol, water, and acetonitrile in an optimal ratio at 0.4 mL/min. The retention times of 5,6-PQ and PQ in plasma and urine were 0.8 and 1.6 min, respectively. The method was validated according to the guideline. The linearity of the analytes was in the range of 25–1500 ng/mL. The matrix effect of PQ and 5,6-PQ ranged from 100% to 116% and from 87% to 104% for plasma, and from 87% to 89% and from 86% to 87% for urine, respectively. The recovery of PQ and 5,6-PQ ranged from 78% to 95% and form 80% to 98% for plasma, and from 102% to from 112% to 97% to 109% for urine, respectively. The accuracy and precision of PQ and 5,6-PQ in plasma and urine were within the acceptance criteria. The samples should be kept in the freezer (−80 °C) and analyzed within 7 days due to the metabolite stability. This validated UHPLC-MS/MS method was beneficial for a pharmacokinetic study in subjects receiving PQ.


Author(s):  
Nesma M Fahmy ◽  
Adel M Michael

Abstract Background Modern built-in spectrophotometer software supporting mathematical processes provided a solution for increasing selectivity for multicomponent mixtures. Objective Simultaneous spectrophotometric determination of the three naturally occurring antioxidants—rutin(RUT), hesperidin(HES), and ascorbic acid(ASC)—in bulk forms and combined pharmaceutical formulation. Method This was achieved by factorized zero order method (FZM), factorized derivative method (FD1M), and factorized derivative ratio method (FDRM), coupled with spectrum subtraction(SS). Results Mathematical filtration techniques allowed each component to be obtained separately in either its zero, first, or derivative ratio form, allowing the resolution of spectra typical to the pure components present in Vitamin C Forte® tablets. The proposed methods were applied over a concentration range of 2–50, 2–30, and 10–100 µg/mL for RUT, HES, and ASC, respectively. Conclusions Recent methods for the analysis of binary mixtures, FZM and FD1M, were successfully applied for the analysis of ternary mixtures and compared to the novel FDRM. All were revealed to be specific and sensitive with successful application on pharmaceutical formulations. Validation parameters were evaluated in accordance with the International Conference on Harmonization guidelines. Statistical results were satisfactory, revealing no significant difference regarding accuracy and precision. Highlights Factorized methods enabled the resolution of spectra identical to those of pure drugs present in mixtures. Overlapped spectra of ternary mixtures could be resolved by spectrum subtraction coupled FDRM (SS-FDRM) or by successive application of FZM and FD1M.


Sign in / Sign up

Export Citation Format

Share Document