New Applications of Thermal Laser Signal Injection Microscopy (T-LSIM)

Author(s):  
R. Aaron Falk ◽  
Neil Bauersfeld ◽  
Mark LaPierre ◽  
Shawn Elliott

Abstract Thermal laser signal injection microscopy (T-LSIM) (aka TIVA and OBIRCH) has shown considerable promise in stateof- the-art digital integrated circuits. The technique has been utilized to locate shorts, leakage currents, problem vias, and timing issues in these devices. However, little has been published on the utility of this technique for analog and mixed signal devices. In this paper we demonstrate the application of T-LSIM on two different analog devices with defects that conventional FA technology and fault isolation techniques were unable to locate. Analog devices produce several unique challenges to the basic T-LSIM technique as typically utilized in the digital regime. Extensions of the basic T-LSIM technique were utilized to locate the failures, which produced unexpected results. The T-LSIM technique has proved essential in the quick identification and localization of failure sites. The T-LSIM technique provides the failure analyst with the analytical power not previously available on conventional fault isolation tools such as emission microscopy and liquid crystal.

2018 ◽  
Author(s):  
Zhi Jie Lau ◽  
Chris Philips

Abstract Thermal-Laser Signal Injection Microscopy (T-LSIM) is a widely used fault isolation technique. Although there are several T-LSIM systems on the market, each is limited in terms of the voltage and current it can produce. In this paper, the authors explain how they incorporated an Amplified External Isolated Source-Sense (AxISS) unit into their T-LSIM platform, increasing its current sourcing capability and voltage biasing range. They also provide examples highlighting the types of faults and failures that the modified system can detect.


Author(s):  
Sarven Ipek ◽  
David Grosjean

Abstract The application of an individual failure analysis technique rarely provides the failure mechanism. More typically, the results of numerous techniques need to be combined and considered to locate and verify the correct failure mechanism. This paper describes a particular case in which different microscopy techniques (photon emission, laser signal injection, and current imaging) gave clues to the problem, which then needed to be combined with manual probing and a thorough understanding of the circuit to locate the defect. By combining probing of that circuit block with the mapping and emission results, the authors were able to understand the photon emission spots and the laser signal injection microscopy (LSIM) signatures to be effects of the defect. It also helped them narrow down the search for the defect so that LSIM on a small part of the circuit could lead to the actual defect.


Author(s):  
Tommaso Melis ◽  
Emmanuel Simeu ◽  
Etienne Auvray

Abstract Getting accurate fault isolation during failure analysis is mandatory for success of Physical Failure Analysis (PFA) in critical applications. Unfortunately, achieving such accuracy is becoming more and more difficult with today’s diagnosis tools and actual process node such as BCD9 and FinFET 7 nm, compromising the success of subsequent PFA done on defective SoCs. Electrical simulation is used to reproduce emission microscopy, in our previous work and, in this paper, we demonstrate the possibility of using fault simulation tools with the results of electrical test and fault isolation techniques to provide diagnosis with accurate candidates for physical analysis. The experimental results of the presented flow, from several cases of application, show the validity of this approach.


Author(s):  
Ikuo Arata ◽  
Shigeru Sakamoto ◽  
Yoshiyuki Yokoyama ◽  
Hirotoshi Terada

Abstract SIL(Solid Immersion Lens) is well investigated for optical pickup application because of its capability of high resolution. We applied this technique to microscopy, especially for precise observation of semiconductors. And also we applied it to fault isolation techniques like emission microscopy , OBIRCH(Optical Beam Induced Resistance Change) and TIVA,SEI. We found significant enhancement of resolution and sensitvity by using SIL. Applying this technique to emission microscopy, we should be aware of optical absorption charactristics of SIL lens materials. We investigated proper SIL lens materials for emission microscopy and laser scanning applications, and checked performance of Si(Silicon)-SIL and GaP(Gallium phosphide)-SIL. We also compared combinations of some kinds of SILs and detectors like C-CCD(cooled CCD) camera, MCT(HgCdTe) camera and position sensitive detector with InGaAs photo cathode II(image intensifier).


Author(s):  
Sagar Karki

Abstract With advancements in technology, it is nearly impossible to find the defects in integrated circuits without applying appropriate failure isolation techniques. Failure isolation is a critical step in identifying the physical defect on integrated circuits. This paper addresses the challenges imposed by floating node conditions on both analog and digital circuitry, and a case study for each circuit type is presented. Different approaches along with the challenges involved in isolating each case in a very timely manner are addressed. Finally, the usefulness of global isolation tools, such as PEM (Photon Emission Microscopy), FIB (Focused Ion Beam), and micro-probing, is also discussed.


Author(s):  
Paul Hubert P. Llamera ◽  
Camille Joyce G. Garcia-Awitan

Abstract Lock-in thermography (LIT), known as a powerful nondestructive fault localization technique, can also be used for microscopic failure analysis of integrated circuits (ICs). The dynamic characteristic of LIT in terms of measurement, imaging and sensitivity, is a distinct advantage compared to other thermal fault localization methods as well as other fault isolation techniques like emission microscopy. In this study, LIT is utilized for failure localization of units exhibiting functional failure. Results showed that LIT was able to point defects with emissions in the mid-wave infra-red (MWIR) range that Photo Emission Microscopy (PEM) with near infrared (NIR) to short- wave infra-red (SWIR) detection wavelength sensitivity cannot to detect.


Author(s):  
Soon Lim ◽  
Jian Hua Bi ◽  
Lian Choo Goh ◽  
Soh Ping Neo ◽  
Sudhindra Tatti

Abstract The progress of modern day integrated circuit fabrication technology and packaging has made fault isolation using conventional emission microscopy via the top of the integrated circuit more difficult, if not impossible. This is primarily due to the use of increased levels and density of metal-interconnect, and the advent of new packaging technology, e.g. flip-chip, ball-grid array and lead-on-chip, etc. Backside photon emission microscopy, i.e. performing photon emission microscopy through the bulk of the silicon via the back of the integrated circuit is a solution to this problem. This paper outlines the failure analysis of sub-micron silicon integrated circuits using backside photon emission microscopy. Sample preparation, practical difficulties encountered and case histories will be discussed.


Sign in / Sign up

Export Citation Format

Share Document