scholarly journals Studi Higiene Sanitasi Makanan Dengan Pemeriksaan Escherichia coli Air Pencucian dan Peralatan Makan Di Pujasera X

2020 ◽  
Vol 5 (4) ◽  
Author(s):  
Yulianti Pratama ◽  
Nadya Almira Rachman

Food sanitation is one of the methods used to protect food from contamination, maintain quality, and prevent potential bacterial transmission. This research was conducted to observe potential diseases caused by the microbiological quality of clean water for household use. MPN method was used to compare the quality of clean water based on the Peraturan Menteri Kesehatan Nomor 416 Tahun 1990. Swab method was implemented to observe the hygiene level of the cutlery to compare with the Peraturan Menteri Kesehatan Nomor 1098 Tahun 2003. 79/100 ml of total coliform found in tenant 1 and tenant 2 which means it did not meet the standards. Escherichia coli were found absent in both clean water sources. The same result comes from 2 samples of plates and spoons before and after the first usage and second usage. In tenant 2, Escherichia coli were found in plate sample no.1 before usage and the clerk’s hands before serving the food. Hence, it did not meet the standards. Based on the interviews and observations, the sanitation hygiene of the clerks and the physical hygiene of tenant 1 and tenant 2 had only fulfilled 61.9% and 57.1% of proper hygiene, so it needed to be improved.

1992 ◽  
Vol 55 (2) ◽  
pp. 104-107
Author(s):  
DEOGHWAN OH ◽  
DOUGLAS L. MARSHALL ◽  
MICHAEL W. MOODY ◽  
J. DAVID BANKSTON

Microbiological analyses were made on samples of cooked blue crab taken immediately after debacking and either forced-air cooling or static-air cooling. Forced-air cooling had significantly lower (P<0.05) total coliform and fecal coliform counts, 2.51 and 2.30 log10 MPN/100 g, compared with those of static-air cooling, 2.83 and 2.60 log10 MPN/100 g. All treatments had less than 2.30 log10 MPN/100 g Escherichia coli. Staphylococcus aureus counts in the forced-air cooled crabs were approximately 4-fold lower than counts in static-air cooled crabs. The aerobic plate counts and psychrotrophic plate counts were significantly lower (P<0.01) by 1.04 and 0.81 log10 CFU/g, respectively, by forced-air cooling compared to static-air cooling. Thermocouple temperature readings were used to determine differences in cooling rates between forced-air and static-air cooling. After 1.5 h of cooling, the initial precooled crabmeat temperature of 34°C (93°F) was reduced by forced-air cooling and static-air cooling to 4°C (40°F) and 20°C (67°F), respectively. The rates of cooling using forced-air and static-air were significantly different (P<0.01).


2020 ◽  
Vol 4 (1) ◽  
pp. 53-59
Author(s):  
Ni Kadek Peniasih ◽  
I Gede Suranaya Pandit ◽  
Dewa Gede Semara Edi

This study aims to determine the microbiological contamination in the main water source of the Muara Nusa Dua Reservoir, the Tukad Badung River, and to determine the microbiological quality of fresh Oreochromis niloticus caught in the Muara Nusa Dua Reservoir in Denpasar. The study was conducted in May-August 2019 at the Denpasar Veterinary Laboratory. The method used is a descriptive method that aims to describe or describe the condition of the Tukad Badung watershed which empties into the Muara Nusa Dua Reservoir (Estuary Dam). Objective tests include the total bacterial test, the Coliform test, and the Escherichia coli contamination test. Water quality measurements are also carried out as supporting data from this study. The results of the study stated that there was microbiological contamination in the water source of the Muara Nusa Dua Reservoir, the Tukad Badung river, which also had an impact on the waters of the Muara Nusa Dua Reservoir. Microbiological contamination research results showed the microbiological quality of ten samples of Oreochromis niloticus in the form of the highest total bacteria was at 2.2x104, the highest total Coliform was 1.9x104 and the highest Escherichia coli contamination was at 93 APM / g with an average reservoir water quality Muara Nusa Dua in the form of temperature 27.3 °C, salinity 0.208 ‰, degree of acidity (pH) 6.5, dissolved oxygen (DO) 5,97 ppm. Organoleptic observations included the appearance, smell, and texture of Oreochromis niloticus with good results because when testing Oreochromis niloticus is still alive


2017 ◽  
Vol 13 (2) ◽  
pp. 111-119
Author(s):  
Lela Uyara ◽  
Pieter Kunu ◽  
Silwanus M Talakua

The study aims to determine the quality of clean water in the villages of Wainitu, Batumerah, Amahusu and Halong by comparing the result of water quality analysis with water quality standard. Water quality analysis includes Physiscal, Chemical, and Microbiological parameters. This research uses descriptive method, this method describes systematics, accurate about facts and characteristic of the quality of clean water of each research location. The results showed that the source of clean water in the village of Batumerah did not meet the standard of clean water quality standards indicated by the number of E. coli and the high total coliform.  Keywords: standard quality of clean water, water quality, Wainitu, Batumerah, Amahusu and Halong villages   ABSTRAK Penelitian yang bertujuan untuk menetapkan kualitas air bersih di Desa Wainitu, Batumerah, Amahusu dan Halong, dengan membandingkan hasil analisis kualitas air dengan standar baku mutu air bersih. Analisis kualitas air meliputi parameter fisika, kimia dan mikrobiologi. Penelitian ini menggunakan metode deskriptif; metode ini menggambarkan sicara sistematis, akurat, fakta dan karakteristik mengenai kualitas air bersih di masing-masing lokasi penelitian. Hasil penelitian menunjukkan bahwa sumber air bersih di Desa Batumerah tidak memenuhi standar baku mutu air bersih yang ditunjukkan oleh jumlah E. coli dan total Koliform yang tinggi. Kata Kunci: baku mutu air bersih, Desa Wainitu, Batumerah, Amahusu dan Halong, kualitas air


1995 ◽  
Vol 31 (5-6) ◽  
pp. 75-79 ◽  
Author(s):  
M. Würzer ◽  
A. Wiedenmann ◽  
K. Botzenhart

In Germany the application of procedures such as flocculation and filtration in the preparation of drinking water results in the annual production of an estimated 500,000 t of sediments and sludges. Some of these residues have a potential for being reused, for example in agriculture, forestry, brickworks or waste water treatment. To assess the microbiological quality of residues from waterworks methods for the detection of enterobacteria, Escherichia coli, Salmonella, Pseudomonas aeruginosa, Legionella, poliovirus, Ascaris suis eggs and Cryptosporidium have been evaluated regarding their detection limits and were applied to various residues from German waterworks. Results show that sediments and sludges may contain pathogenic bacteria, viruses and protista. When residues from waterworks are intended to be reused in agriculture or forestry the microbiological quality should therefore be considered.


1983 ◽  
Vol 46 (11) ◽  
pp. 978-981 ◽  
Author(s):  
B. A. WENTZ ◽  
A. P. DURAN ◽  
A. SWARTZENTRUBER ◽  
A. H. SCHWAB ◽  
R. B. READ

The microbiological quality of fresh blue crabmeat, soft- and hardshell clams and shucked Eastern oysters was determined at the retail (crabmeat, oysters) and wholesale (clams) levels. Geometric means of aerobic plate counts incubated at 35°C were: blue crabmeat 140,000 colony-forming units (CFU)/g, hardshell clams, 950 CFU/g, softshell clams 680 CFU/g and shucked Eastern oysters 390,000 CFU/g. Coliform geometric means ranged from 3,6/100 g for hardshell clams to 21/g for blue crabmeat. Means for fecal coliforms or Escherichia coli ranged from <3/100 g for clams to 27/100 g for oysters, The mean Staphylococcus aureus count in blue crabmeat was 10/g.


2009 ◽  
Vol 39 (6) ◽  
pp. 1836-1841 ◽  
Author(s):  
Thaís Mioto Martineli ◽  
Oswaldo Durival Rossi Junior ◽  
Natacha Deboni Cereser ◽  
Marita Vedovelli Cardozo ◽  
Cristianne Lino Fontoura ◽  
...  

The consumption of lamb meat in Brazil has increased in the last years but little information about the microbiological quality of this product is available. To evaluate the hygienic-sanitary conditions of lamb carcasses, the quantification of microorganism populations indicators (mesophiles and psychrotrophs; total and thermotolerant coliforms; Escherichia coli; moulds and yeasts) and the pathogenic microorganisms indentification (Salmonella sp. and Listeria spp.) were performed. A total of 60 lamb carcasses were sampled from one abattoir in São Paulo. Swab samples were collected from three points (forequarter, back and hindquarter) on the muscle surface after carcasses final washing. Statistical analysis consisted of descriptive evaluation of the results whose counts were grouped by intervals of microorganism populations. Counts ranged from 1.0 x 10¹ to 8.0 x 10(4) colony-forming unit cm-2 (CFU cm-2) for mesophiles; 1.0 x 10(0) to 4.4 x 10(4)CFU cm-2 for psychrotrophs; < 1.0 x 10(0) to 4.4 x 10(4)CFU cm-2 for moulds and yeasts; < 0.3 to > 32.0 most probable number/cm² (MPN cm-2) for total and thermotolerant coliforms and Escherichia coli. Salmonella sp. and Listeria spp. were not found in any of the carcasses. Most carcasses presented low counts for all microorganisms. Overall results may be explained by the small size of the industry where the study was taken. Results suggest that good microbiological quality lamb meat is possible to be obtained, but improvement in hygienic-sanitary conditions is still required.


1986 ◽  
Vol 49 (3) ◽  
pp. 229-230 ◽  
Author(s):  
DONALD W. WARBURTON ◽  
PEARL I. PETERKIN ◽  
KARL F. WEISS

A study done in 1980 to 1981 assessed the overall bacteriological quality of three varieties of domestic and imported processed cheese products. All of the 78 lots tested had counts of &lt;1.8 Escherichia coli and coliforms/g, and had no staphylococcal thermonuclease activity. Domestic products had significantly higher levels of aerobic sporeformers than imported products (α = 0.05), whereas the differences in levels of anaerobic sporeformers in these products were not significant. Results of this study indicated that good manufacturing practices were used during the processing of these products.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Ollo Kambire ◽  
Konan Mathurin Yao ◽  
Andrée Emmanuelle Sika ◽  
Aminata Coulibaly ◽  
Zamble Bi Irie Abel Boli ◽  
...  

“Soumbara” is a fermented product sold in the markets of several West African countries. In the markets, it is sold in several formats (granulated, powder, and paste). The objective of this study was to evaluate the microbiological and physicochemical characteristics of these three types of “Soumbara” sold in the Korhogo markets. For this purpose, a preliminary survey followed by a sampling of 54 samples of “Soumbara” was carried out. The microorganism load count was carried out according to microbiological standards. The pH, titratable acidity, and moisture content were measured, respectively, with a pH meter, by dosing with sodium hydroxide solution and by differential weighing after passing the sample through the oven. The pH of the different samples is around 6. The moisture content is higher in “Soumbara” paste (20-24.7%) than in powdered (7.3-9.3%) and granulated (8.6-10.7%) “Soumbara.” The acidity rates are between 0.07 and 0.13%, 0.2 and 0.3%, and 0.08 and 0.1%, respectively, for the granulated, powder, and paste types. Mesophilic aerobic germ loads (6.17-8.38 log10 cfu/g) for all three types of “Soumbara” are above the standard. Total coliform (1.13-2.96 log10 cfu/g), mould (0.86-2.52 log10 cfu/g), and yeast (0.33-1.53 log10 cfu/g) loads are below standard. The microbiological quality of the three types of “Soumbara” is unsatisfactory. Overall, “Soumbara” powder is the most contaminated, followed by granulated and paste “Soumbara.” “Soumbara” must be added during culinary preparations in order to avoid possible public health problems.


Author(s):  
Nesrin Kaval ◽  
Nilgün Öncül ◽  
Zeliha Yıldırım

In this study, the microbiological quality of traditionally produced Bez Sucuk in Tokat and its vicinity was investigated. For this purpose, 30 Bez Sucuk samples obtained from butchers, producers of Bez Sucuk, were analyzed for total count of mesophilic aerobic bacteria, lactic acid bacteria, yeasts-moulds, total coliform, fecal coliform, Staphylococcus aureus, Bacillus cereus, and Cl. perfringens. Also, the presence of Escherichia coli O157:H7, Listeria monocytogenes and Salmonella spp. were investigated in all samples. pH and water activity of the samples were determined. As the result of the analysis, the counts of the microbiological parameters investigated were found as follows: total mesophilic aerobic bacteria 3.5×106-4.23×109 CFU/g, lactic acid bacteria 5.55×105-2.45×109 CFU/g, yeasts and moulds 2.50×103-6.90×109 CFU/g, total coliform


Sign in / Sign up

Export Citation Format

Share Document