scholarly journals Optimization Design of Spray Cooling Fan Based on CFD Simulation and Field Experiment for Horticultural Crops

Agriculture ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 566
Author(s):  
Yongguang Hu ◽  
Yongkang Chen ◽  
Wuzhe Wei ◽  
Zhiyuan Hu ◽  
Pingping Li

In recent years, horticultural plants have frequently suffered significant heat damage due to excessive temperatures. In this study, a horticultural spray cooling system was designed, consisting mainly of a jet fan and spraying system. CFD simulation technology and response surface methodology were used to optimize the design of the jet fan, which improved the thrust of the fan. The length of the inlet section was 300 mm, the length of the outlet section was 300 mm, the length of the cone section was 450 mm, and the diameter of the outlet was 950 mm, where the thrust of the jet fan was 225.06 N. By establishing the CFD model of spray cooling in a tea field and designing a L9 (34) orthogonal experiment, the effect of the spray parameters on the maximum temperature drop and effective cooling distance was studied, and the best parameters were selected. The simulation results show that the optimum parameters are a spray flow rate of 4.5 kg/s, a droplet diameter of 15–45 μm, a droplet temperature of 298.15 K, and a nozzle double circle layout. Based on the simulation results of the optimized jet fan and spray parameters selected, a spray cooling test bench was established. Field test results show that when the initial ambient temperature was 310.05 K–310.95 K, the maximum temperature drop of the spray cooling fan was 9.1 K, and the cooling distance was approximately 36.0 m. The temperature drop decreased with increasing distance from the fan. This study is of great significance to protect horticultural plants from extremely high temperatures.

2013 ◽  
Vol 753-755 ◽  
pp. 2709-2712 ◽  
Author(s):  
Ya Na Qie ◽  
Shu Hui Zhang ◽  
Qing Lv ◽  
Li Hong Zhang

Life span of water cooling tuyere is one of important factors of blast furnace’s direct motion and high yield. In order to improve the life of tuyere, the flow fleld and temperature field of tuyere were simulated by using computational fluid dynamics (CFD). Simulation results show that the maximum temperature appears at the front margin of tuyere outlet side. The highest temperature of tuyere reduces significantly with the increase of water pressure below 0.4MPa. When the water pressure exceeds 0.4Pa, the highest temperature reduces slowly. In consideration of economic benefit and cooling effect, the best point of inlet pressure is 0.4MPa or so.


Author(s):  
Rama R. Goruganthu ◽  
David Bethke ◽  
Shawn McBride ◽  
Tom Crawford ◽  
Jonathan Frank ◽  
...  

Abstract Spray cooling is implemented on an engineering tool for Time Resolved Emission measurements using a silicon solid immersion lens to achieve high spatial resolution and for probing high heat flux devices. Thermal performance is characterized using a thermal test vehicle consisting of a 4x3 array of cells each with a heater element and a thermal diode to monitor the temperature within the cell. The flip-chip packaged TTV is operated to achieve uniform heat flux across the die. The temperature distribution across the die is measured on the 4x3 grid of the die for various heat loads up to 180 W with corresponding heat flux of 204 W/cm2. Using water as coolant the maximum temperature differential across the die was about 30 °C while keeping the maximum junction temperature below 95 °C and at a heat flux of 200 W/cm2. Details of the thermal performance of spray cooling system as a function of flow rate, coolant


2011 ◽  
Vol 339 ◽  
pp. 148-151 ◽  
Author(s):  
Shu Juan Zheng ◽  
Long Quan

This paper optimizes the structure of the poppet valve based on the internal flow. The flow-force on poppet valve in the case of the converging flow is simulated and studied by CFD. Simulation results represent that the traditional formula for computing the flow-force can be used only in the certain range, so the formula is modified based on the simulation result.


2014 ◽  
Vol 70 (7) ◽  
pp. 1285-1291 ◽  
Author(s):  
Jia-jia Deng ◽  
Liang-ming Pan ◽  
De-qi Chen ◽  
Yu-quan Dong ◽  
Cheng-mu Wang ◽  
...  

Aimed at cost saving and pollution reduction, a novel desulfurization wastewater evaporation treatment system (DWETS) for handling wet flue gas desulfurization (WFGD) wastewater of a coal-fired power plant was studied. The system's advantages include simple process, and less investment and space. The feasibility of this system has been proven and the appropriate position and number of nozzles, the spray droplet size and flue gas temperature limitation have been obtained by computational fluid dynamics (CFD) simulation. The simulation results show that a longer duct, smaller diameter and higher flue gas temperature could help to increase the evaporation rate. The optimal DWETS design of Shangdu plant is 100 μm droplet sprayed by two nozzles located at the long duct when the flue gas temperature is 130 °C. Field tests were carried out based on the simulation results. The effects of running DWETS on the downstream devices have been studied. The results show that DWETS has a positive impact on ash removal efficiency and does not have any negative impact on the electrostatic precipitator (ESP), flue gas heat exchanger and WFGD. The pH values of the slurry of WFGD slightly increase when the DWETS is running. The simulation and field test of the DWETS show that it is a feasible future technology for desulfurization wastewater treatment.


Author(s):  
Eugen-Dan Cristea ◽  
Pierangelo Conti

Three dimensional, time dependent Euler-Euler simulation approach for numerical calculation of multiphase strongly swirling turbulent gas-heavy laden particulate flow in large industrial collection cyclones, positioned vertically, in staggered downward cascade arrangement has been performed. The multiphase flow was featured high mass loading. This paper specifically addresses a CFD modeling of a “suspension preheater”, typical equipment for dry process cement kiln. Big sized cyclone separator is a key component of this device. The simulation case study was developed in the frame of the commercial general-purpose code ANSYS-Fluent R13. In cyclone separators the swirling gas motion induces a centrifugal force on the solid particulate phase which is the driving force behind the separation process. The turbulence disperses the solid particulates and enhances the probability that particles are discharged, as reject. Both phenomena are related to solid phase particle size distribution (PSD) and flow pattern into the collection cyclones. The multiphase turbulence was modeled using the RSM Mixture Turbulence Model. The simulation results were validated against industrial measurements carried out on an industrial suspension preheater, in the frame of heat and mass balance of cement kiln energy audit. The numerical simulation results were found in reasonable agreement with the collected industrial measurements. This CFD simulation represents a powerful engineering tool on behalf of the cement process engineer either for new cutting-edge design or for performance verification of an existing plant.


Author(s):  
Jianshu Lin ◽  
Hong Wang

A comprehensive analysis method is proposed to resolve the problem of simulating a complex thermo-flow with two kinds of distinct characteristic length in the dry gas seal, and a conjugated simulation of the complicated heat transfer and the gas film flow is carried out by using the commercial CFD software CFX. By using the proposed method, a three dimensional of velocity and pressure field in the gas film flow and the temperature distribution within the sealing rings are investigated for three kinds of film thickness, respectively. A comparison of thermo-hydrodynamics of the dry gas seals is conducted between the sealed gas of air and helium. The latter one is used in a helium circulator for High Temperature Gas-cooled Reactor (HTGR). From comparisons and discussions of a series of simulation results, it will be found that the comprehensive proposal is effective and simulation results are reasonable, and the maximum temperature rise in the dry gas seal is within the acceptable range of HTGR safety requirements.


The shape of a radiator cover is crucial either in determining the pattern of air flow or in increasing the same through the radiator core thereby increasing the thermal efficiency, thus making it a necessity to understand it. Moreover the parts circumjacent to the core namely the upper tank, lower tank, cooling fan, fins, tubes, etc promote the air flow rate. Also it is to note that the air flow rate of discharge gases from radiator core is one of the prime factors in determining the automobile cooling system. Initially factors such as temperature, pressure, air flow rate that affect the performance are obtained in order to derive out the entities of operation. One of the observations that can be made through this paper is that as the volume of the coolant increases, the rate of heat dissipation increases, also parameters like inlet temperature and volume flow rate of coolant, air velocity, temperature drop and drop in pressure of coolant are factors that contribute in radiator performance evidently.


2020 ◽  
Vol 165 ◽  
pp. 01006
Author(s):  
Yiquan Guo ◽  
Junying Zhang

In this paper, a collision model between atomized droplets of agglomeration solution and particles is established. On this basis, the effects of flue gas temperature, atomized droplet diameter and other factors on the particle agglomeration process are studied. In addition, the evaporation model of agglomeration solution in the flue of a power plant is established for the coal-fired unit of power plant. Through CFD software, the variation of flow field velocity, temperature and pressure in the flue is simulated to determine whether the chemical agglomeration technology has negative impact on the actual operating conditions of the power plant. The simulation results show that the velocity and pressure of the flow field in the flue have no obvious change after the agglomerating agent is injected. Besides, the temperature drop of about 7°C. The droplets evaporate completely at a distance of 7-8 m after spraying. The evaporation time of droplets is within 1.6 s.


2018 ◽  
Vol 180 ◽  
pp. 02044 ◽  
Author(s):  
Roman Klas ◽  
Vladimír Habán ◽  
Pavel Rudolf

Several modifications were developed when designing the nozzle valve. This study offers an assessment of the properties of new modifications of the nozzle valve design. The main operating characteristics, such as loss and flow coefficients, were determined using a CFD methods. Besides mentioned coefficients, the forces acting on the valve disc are also decisive for the behavior of the valve, both in its steady and unsteady operation. It is important to examine the possible simplification and matching of CFD simulation results from 2D and 3D geometries in terms of subsequent dynamic analysis of the valve. This will be taken into consideration by comparing the above-mentioned operating characteristics, by analyzing the forces acting on the valve disc and comparing the velocity and pressure fields.


Sign in / Sign up

Export Citation Format

Share Document