scholarly journals Microstructure and Mechanical Property of Compact Graphite/6061Al Composite Prepared by Ultra-High Pressure Sintering

2020 ◽  
Vol 10 (15) ◽  
pp. 5107 ◽  
Author(s):  
Changyun Li ◽  
Yasong Wang ◽  
Lei Xu ◽  
Yang Liu ◽  
Ningning Lu ◽  
...  

Graphite/6061 aluminum (G/6061Al) composites with different content of graphite were ultra-high pressure (UHP)-sintered and hot pressing (HP)-sintered, respectively. The result shows that homogeneous dispersion of graphite flakes in the 6061Al matrix can be achieved using graphite flakes coated by nano-Al particles, both in the UHP-sintered and in the HP-sintered composite. Due to the comprehensive effects of ultra-high pressure, high temperature and formation of Al4C3, the UHP-sintered composites endowed with higher relative density, higher hardness, stronger tensile strength and better wear resistance than the HP-sintered composite. The highest tensile strength of the UHP-sintered with 5 vol.% graphite is 183 MPa. Wear test reveals that the wear rate of the UHP sintered with 10 vol.% G/6061Al decreases drastically when the sintering temperature is 650 °C or higher, which is one to three orders of magnitude lower than that of the HP-sintered. The lowest wear rate of the UHP sintered with 10 vol.% graphite is 0.15 × 10−5 g/mm, while that of the HP-sintered composite is 133 × 10−5 g/mm.

2020 ◽  
Vol 10 (20) ◽  
pp. 7363
Author(s):  
Lei Xu ◽  
Erkuo Yang ◽  
Yasong Wang ◽  
Changyun Li ◽  
Zhiru Chen ◽  
...  

Ultra high-pressure sintering (UHPS) was used to prepare AA6061/SiCp composites with different contents and the effect of sintering temperatures on microstructure and mechanical properties was investigated in this study. The results showed that a uniform distribution of nano-SiC particles (N-SiCp) is obtained by the UHPS method. With the increase in N-SiCp contents, the higher hardness and better wear resistance could be inspected. The interfacial reactions and Al4C3 phase appeared above 550 °C. The relative density of composites first increased and then decreased; with the temperature raising it reached 99.58% at 600 °C. The hardness and wear property showed the same trend with the hardness reaching 52 HRA and wear rate being 1.0 × 10−6 g/m at 600 °C. Besides, the wear mechanism of the composites is mainly composed of abrasive wear and adhesive wear.


2021 ◽  
Vol 73 (07) ◽  
pp. 53-54
Author(s):  
Chris Carpenter

This article, written by JPT Technology Editor Chris Carpenter, contains highlights of paper NACE 2020-14695, “Comparison of Stress Corrosion Cracking Behavior of Fe13Cr5Ni- and Fe17Cr5.5Ni-Based High-Chromium Stainless Steels in High-Pressure/High-Temperature CO2 Environments,” by Yameng Qi, Zhonghua Zhang, and Chunxia Zhang, Baoshan Iron and Steel, prepared for the 2020 NACE International Corrosion Conference and Exposition, Houston, 14–18 June. The paper has not been peer reviewed. Stress corrosion cracking (SCC) of Fe13Cr5Ni- and Fe17Cr5.5Ni-based alloys in high-pressure/high-temperature (HP/HT) carbon dioxide (CO2) environments was investigated through slow-strain-rate tests (SSRTs) and electrochemical methods. The results show that a remarkable decrease in tensile strength and elongation to failure was observed when testing in a CO2 environment compared with that of air. Fe17Cr5.5Ni-based alloys possessed better SCC resistance than Fe13Cr5Ni-based alloys. The better SCC resistance of the former could be attributed to good repassivation capacity and pitting-corrosion resistance induced by the increase in chromium (Cr) and nickel (Ni) content. Introduction When service temperature exceeds 150°C, SCC resistance of Fe13Cr5Ni-based alloys could become an issue. Compared with Fe13Cr5Ni-based alloys, 22Cr duplex stainless steel has an excel-lent performance when exposed to temperatures over 150°C and stable SCC resistance in HP/HT CO2 environments. However, the cost of 22Cr duplex stainless steel is extremely high. Experimental Procedure Fe13Cr5Ni- and Fe17Cr5.5Ni-based alloys were produced by the authors’ research institute. The materials were in a quenched and tempered state. For micrographic observation, each specimen was ground with 2,000-grit carbide silicon paper and polished with 1.2-µm diamond paste. They were then degreased with acetone and etched with hydrochloric ferric chloride solution (a mixture of 5-g ferric chloride, 25-mL hydrochloric acid, and 25-mL ethanol). The steel microstructures were characterized using an optical micro-scope. The micrograph in Fig. 1a for the F-13Cr5Ni-based alloys shows a martensite phase with no notable second phases. Fe17Cr5.5Ni alloys possess long strip ferrite and martensite phases (Fig. 1b). For SSRTs, smooth tensile specimens with a gauge length of 25.4 mm and a diameter of 3.81 mm were prepared. The specimens were cut from the Fe13Cr5Ni- and Fe17Cr5.5Ni-based alloys into an 8-mm-thick, 12-mm-outer- diameter disc for electrochemical measurement. All specimens were polished to a 1,200-grit surface finish, degreased with acetone, cleansed with distilled water, and dried in air. SSRT and electrochemical-measurement procedures are detailed in the complete paper. Results SCC Susceptibility. As expected, tensile strength and elongation to failure of Fe13Cr5Ni- and Fe17Cr5.5Ni-based alloys deteriorated in HP/HT CO2 environments. Compared with an environment of air, the elongation to failure of Fe13Cr5Ni- and Fe17Cr5.5Ni-based alloys in HP/HT CO2 environments decreased by approximately 30 and 25%, respectively. In addition, tensile strength and elongation to failure of Fe17Cr5.5Ni-based alloys were greater than those of Fe13Cr5Ni-based alloys. Elongation, reduction in area, and time to failure of Fe17Cr5.5Ni-based alloys were found to be much higher than that of Fe13Cr5Ni-based alloys in HP/HT CO2 environments. It can be concluded that Fe17Cr5.5Ni alloys possess better SCC resistance than Fe13Cr5Ni alloys in these environments.


2014 ◽  
Vol 59 (1) ◽  
pp. 205-209 ◽  
Author(s):  
I. Sulima ◽  
L. Jaworska ◽  
P. Figiel

Abstract In this paper the properties of the austenitic stainless steel reinforced with various volume fractions of TiB2 ceramics have been studied. The high pressure- high temperature (HP-HT) method of sintering was applied to the formation of composites. Samples were sintered at pressure of 5 and 7 ±0.2 GPa and temperatures of 1273 K and 1573 K. For the tested materials, the relative density, Young’s modulus and hardness were measured. In order to investigate the structure changes, the scanning electron microscope was used. The obtained results show that the temperature and pressure influence on the mechanical and physical properties of the investigated composites.


2017 ◽  
Vol 898 ◽  
pp. 35-40 ◽  
Author(s):  
Wen Jian Lv ◽  
Bo Long Li ◽  
Peng Qi ◽  
Zuo Ren Nie

The 6061 aluminum alloys with different content of erbium were prepared. The erbium content was optimized by measurement of grain refining effects and tensile strength. After solid solution treatment of the alloy with optimized erbium content at 505 °C ~ 595 °C for 4 h. and then ageing at –160 °C ~ 200 °C for 3 h., the grain size decreased with the content of erbium, achieving the most effective grain size refinement at the erbium content of 0.15wt.%. The tensile strength of as-cast alloy could reach up to 243 MPa at the erbium content of 0.15%. -Combined with the microstructures and mechanical properties, the erbium content of 0.15% was the optimized content, and heat treatments of ageing at 180 °C for 3 h. followed by solid solution at 565 °C for 4 h were suggested.


Sign in / Sign up

Export Citation Format

Share Document