scholarly journals Design and Testing of a LUT Airfoil for Straight-Bladed Vertical Axis Wind Turbines

2018 ◽  
Vol 8 (11) ◽  
pp. 2266 ◽  
Author(s):  
Shoutu Li ◽  
Ye Li ◽  
Congxin Yang ◽  
Xuyao Zhang ◽  
Qing Wang ◽  
...  

The airfoil plays an important role in improving the performance of wind turbines. However, there is less research dedicated to the airfoils for Vertical Axis Wind Turbines (VAWTs) compared to the research on Horizontal Axis Wind Turbines (HAWTs). With the objective of maximizing the aerodynamic performance of the airfoil by optimizing its geometrical parameters and by considering the law of motion of VAWTs, a new airfoil, designated the LUT airfoil (Lanzhou University of Technology), was designed for lift-driven VAWTs by employing the sequential quadratic programming optimization method. Afterwards, the pressure on the surface of the airfoil and the flow velocity were measured in steady conditions by employing wind tunnel experiments and particle image velocimetry technology. Then, the distribution of the pressure coefficient and aerodynamic loads were analyzed for the LUT airfoil under free transition. The results show that the LUT airfoil has a moderate thickness (20.77%) and moderate camber (1.11%). Moreover, compared to the airfoils commonly used for VAWTs, the LUT airfoil, with a wide drag bucket and gentle stall performance, achieves a higher maximum lift coefficient and lift–drag ratios at the Reynolds numbers 3 × 105 and 5 × 105.

Author(s):  
Xiaomin Chen ◽  
Ramesh Agarwal

In this paper, we consider the Wind Farm layout optimization problem using a genetic algorithm. Both the Horizontal–Axis Wind Turbines (HAWT) and Vertical-Axis Wind Turbines (VAWT) are considered. The goal of the optimization problem is to optimally place the turbines within the wind farm such that the wake effects are minimized and the power production is maximized. The reasonably accurate modeling of the turbine wake is critical in determination of the optimal layout of the turbines and the power generated. For HAWT, two wake models are considered; both are found to give similar answers. For VAWT, a very simple wake model is employed.


2021 ◽  
pp. 0309524X2110618
Author(s):  
Syed Abdur Rahman Tahir ◽  
Muhammad Shakeel Virk

Vertical Axis Wind Turbine (VAWT) can be a promising solution for electricity production in remote ice prone territories of high north, where good wind resources are available, but icing is a challenge that can affect its optimum operation. A lot of research has been made to study the icing effects on the conventional horizontal axis wind turbines, but the literature about vertical axis wind turbines operating in icing conditions is still scarce, despite the importance of this topic. This paper presents a review study about existing knowledge of VAWT operation in icing condition. Focus has been made in better understanding of ice accretion physics along VAWT blades and methods to detect and mitigate icing effects.


10.6036/10376 ◽  
2022 ◽  
Vol 97 (1) ◽  
pp. 11-11
Author(s):  
MARLON GALLO TORRES ◽  
ENEKO MOLA SANZ ◽  
IGNACIO MUGURUZA FERNANDEZ DE VALDERRAMA ◽  
AITZOL UGARTEMENDIA ITURRIZAR ◽  
GONZALO ABAD BIAIN ◽  
...  

There are two wind turbine topologies according to the axis of rotation: horizontal axis, "Horizontal Axis Wind Turbines" (HAWT) and vertical axis, "Vertical Axis Wind Turbines" (VAWT) [2]. HAWT turbines are used for high power generation as they have a higher energy conversion efficiency [2]. However, VAWTs are used in mini wind applications because they do not need to be oriented to the prevailing wind and have lower installation cost.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 5140
Author(s):  
Altaf Hussain Rajpar ◽  
Imran Ali ◽  
Ahmad E. Eladwi ◽  
Mohamed Bashir Ali Bashir

Developments in the design of wind turbines with augmentation are advancing around the globe with the goal of generating electricity close to the user in built-up areas. This is certain to help lessen the power generation load as well as distribution and transmission network costs by reducing the distance between the user and the power source. The main objectives driving the development and advancement of vertical-axis wind turbines are increasing the power coefficient and the torque coefficient by optimizing the upstream wind striking on the rotor blades. Unlike horizontal-axis wind turbines, vertical axis turbines generate not only positive torque but also negative torque during operation. The negative torque generated by the returning blade is a key issue for vertical-axis wind turbines (VAWTs) that is counterproductive. Installation of wind deflectors for flow augmentation helps to reduce the negative torque generated by the returning blades as well as enhance the positive torque by creating a diversion in the upstream wind towards the forwarding blade during operation. This paper reviews various designs, experiments, and CFD simulations of wind deflectors reported to date. Optimization techniques for VAWTs incorporating wind deflectors are discussed in detail. The main focus of the review was on the installation position and orientation of the deflectors and their potential contribution to increasing the power coefficient. Topics for future study are suggested in the conclusion section of the paper.


2007 ◽  
Vol 31 (5) ◽  
pp. 363-368 ◽  
Author(s):  
A. Biswas ◽  
R. Gupta ◽  
K.K. Sharma

Savonius vertical axis wind turbines (VAWT) have advantages over horizontal axis wind turbines (HAWT), such as simple construction, acceptance of wind from any direction without orientation, self-starting, inexpensive etc. These advantages make it a viable proposition for small-scale applications in developing countries. In spite of the above advantages, VAWT are not gaining popularity mainly because of their poor efficiency. Hence, a three-bucket Savonius model rotor, having 8 cm bucket diameter and 20 cm height, was designed, fabricated, and tested in a sub-sonic wind tunnel. Provisions for variations of ‘blade’ overlap were included. Experiments were conducted for overlap conditions in the range of 16% to 35%. From the experimental investigations, power-coefficients (Cp) were calculated with and without blockage correction factors for tunnel interference. In both analyses, the power-coefficient increased if there was overlap, with an optimum value at 20% overlap of 47% without blockage correction, and 38% with blockage correction.


Author(s):  
Michael Borg ◽  
Kai Wang ◽  
Maurizio Collu ◽  
Torgeir Moan

As part of the deployment of floating offshore wind turbines (FOWTs) in deep sea, robust coupled dynamic design codes based on engineering models are being developed to investigate the behaviour of FOWTs in the offshore environment. The recent re-emerging interest in vertical axis wind turbines (VAWTs) for floating foundation applications has resulted in a number of design codes being developed concurrently by different researchers. In this study, two such design codes for floating VAWTs developed at Cranfield University and the Norwegian University of Science and Technology are compared through a series of increasingly complex simulation load cases. A floating VAWT design was specified to be used in this study. The rotor is based on the Darrieus Troposkein shape and is the same used within the DeepWind VAWT spar concept, with a 5MW rated capacity. The floating support structure is a semi-submersible that is being used in the Offshore Code Collaboration Continuation (OC4) Phase II project for floating horizontal axis wind turbines. A series of load cases were set out to assess and compare the two different design codes. A comparison of the performance of the two design tools is presented, illustrating their level of maturity and areas of improvement.


Author(s):  
Roman Albertovich Ilyin ◽  
Nickolai Dmitrievich Shishkin

Analysis of aerodynamics and energy efficiency made it possible to estimate power factors of the most effective up-to-date vertical axis wind turbines. Resistance forces in the traverse flow are so great that they can result in reduction of a power factor from 0.56 to 0.28, i.e. in 2 times. With an increase of angle of the blades placing from 0º to 4º, the power factor increased from 0.40 to 0.61, i. e. in 1,5 times. Optimization of geometric parameters and improvement of generating lines of the blades can increase efficiency of Н-Darier rotor up to 0.72, which exceeds the maximum possible value for horizontal axis wind turbines (0.45). With increasing relative width of the semicylindrical blade from 0.1 to 0.5 and increasing the number of blades from 2 to 6, the power factor of Savonius rotor raises from 0.018 to 0.226. To reduce energy losses in Savonius rotor it is possible to use inclined generators and end elements of blades of various shapes.


Sign in / Sign up

Export Citation Format

Share Document