scholarly journals Effects of Climate Change for Thermal Comfort and Energy Performance of Residential Buildings in a Sub-Saharan African Climate

Buildings ◽  
2019 ◽  
Vol 9 (10) ◽  
pp. 215 ◽  
Author(s):  
Dodoo ◽  
Ayarkwa

This study presents an analysis of the impacts of climate change on thermal comfort and energy performance of residential buildings in Ghana, in sub-Saharan Africa, and explores mitigation as well as adaptation strategies to improve buildings’ performance under climate change conditions. The performances of the buildings are analyzed for both recent and projected future climates for the Greater Accra and Ashanti regions of Ghana, using the IDA-ICE dynamic simulation software, with climate data from the Meteonorm global climate database. The results suggest that climate change will significantly influence energy performance and indoor comfort conditions of buildings in Ghana. However, effective building design strategies could significantly improve buildings’ energy and indoor climate performances under both current and future climate conditions. The simulations show that the cooling energy demand of the analyzed building in the Greater Accra region is 113.9 kWh/m2 for the recent climate, and this increases by 31% and 50% for the projected climates for 2030 and 2050, respectively. For the analyzed building in the Ashanti region, the cooling energy demand is 104.4 kWh/m2 for the recent climate, and this increases by 6% and 15% for the 2030 and 2050 climates, respectively. Furthermore, indoor climate and comfort deteriorate under the climate change conditions, in contrast to the recent conditions.

Atmosphere ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 715
Author(s):  
Cristina Andrade ◽  
Sandra Mourato ◽  
João Ramos

Climate change is expected to influence cooling and heating energy demand of residential buildings and affect overall thermal comfort. Towards this end, the heating (HDD) and cooling (CDD) degree-days along with HDD + CDD were computed from an ensemble of seven high-resolution bias-corrected simulations attained from EURO-CORDEX under two Representative Concentration Pathways (RCP4.5 and RCP8.5). These three indicators were analyzed for 1971–2000 (from E-OBS) and 2011–2040, and 2041–2070, under both RCPs. Results predict a decrease in HDDs most significant under RCP8.5. Conversely, it is projected an increase of CDD values for both scenarios. The decrease in HDDs is projected to be higher than the increase in CDDs hinting to an increase in the energy demand to cool internal environments in Portugal. Statistically significant linear CDD trends were only found for 2041–2070 under RCP4.5. Towards 2070, higher(lower) CDD (HDD and HDD + CDD) anomaly amplitudes are depicted, mainly under RCP8.5. Within the five NUTS II


2018 ◽  
Vol 57 ◽  
pp. 04001 ◽  
Author(s):  
Albert Al Touma ◽  
Djamel Ouahrani

Al-Majlis is the living space in residential buildings of the Arabian Gulf, and is where occupants spend most of their time. For this reason, the human thermal comfort in this space is of extreme importance and is often compromised due to hot outdoor weather conditions. In contrast with many thermal discomfort mitigation methods in outdoor environments, which become unadvisable in indoor spaces, this study investigates the effect of adding PCM-enhanced tiles to portions of the indoor envelope on the occupant’s thermal comfort and the space cooling energy demand. A simulation model of a space with tight building envelope in Qatar was developed on EnergyPlus with and without the addition of PCM-enhanced tiles. The selected country is a representative location of the Arabian Gulf. Considering different occupant’s positions, the addition of the tiles with PCM on their back was found to moderate the mean radiant temperature, operative temperature, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD), all of which signify an improvement in the human thermal comfort. Lastly, this change in the indoor envelope was found to save 3.3% of the space daily thermal cooling energy demand during one harsh summer representative day.


Energies ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 7420
Author(s):  
Sangtae No

Countries around the world develop and use software based on the monthly calculation method of DIN V 18599:2007 and EN ISO13790 for building energy performance evaluations. The purpose of this study is to propose a method that can consider the effect of reducing cooling energy demand by hybrid ventilation outdoor air cooling in monthly calculation method-based software. For ventilation simulation, some representative floor plans and area types of Korean residential buildings were established through literature research. A number of dynamic energy simulations were performed for various building orientations, heights, and opening factors. Based on the simulation results, a nomograph that can calculate the cooling energy demand reduction factor according to hybrid ventilation that can be applied to the ventilation heat transfer coefficient is proposed.


Author(s):  
C. León-Sánchez ◽  
D. Giannelli ◽  
G. Agugiaro ◽  
J. Stoter

Abstract. The 3D BAG v. 2.0 dataset has been recently released: it is a country-wide dataset containing all buildings in the Netherlands, modelled in multiple LoDs (LoD1.2, LoD1.3 and LoD2.2). In particular, the LoD2.2 allows differentiating between different thematic surfaces composing the building envelope. This paper describes the first steps to test and use the 3D BAG 2.0 to perform energy simulations and characterise the energy performance of the building stock. Two well-known energy simulation software packages have been tested: SimStadt and CitySim Pro. Particular care has been paid to generate a suitable, valid CityGML test dataset, located in the municipality of Rijssen-Holten in the central-eastern part of the Netherlands, that has been then used to test the energy simulation tools. Results from the simulation tools have been then stored into the 3D City Database, additionally extended to deal with the CityGML Energy ADE. The whole workflow has been checked in order to guarantee a lossless dataflow.The paper reports on the proposed workflow, the issues encountered, some solutions implemented, and what the next steps will be.


2019 ◽  
Vol 282 ◽  
pp. 02066
Author(s):  
Fuad Mutasim Baba ◽  
Hua Ge

Buildings now produce more than a third of global greenhouse gases, making them more than any other sector contributing to climate change. This paper investigates the effect of climate change on the energy performance and thermal comfort of a high-rise residential building with different energy characteristic levels, i.e. bylaw to meet current National Energy Code of Canada for Buildings (NECB), and passive house (PH) under two climate zones in British Columbia, Canada. SRES A2, RCP-4.5 and RCP-8.5 emission scenarios are used to generate future horizon weather data for 2020, 2050, and 2080. The simulation results show that for both bylaw and PH cases, the heating energy consumption would be reduced while cooling energy consumption would be increased. As a result, for the bylaw case, the total energy consumption would be decreased for two climate zones, while for PH case, the total energy consumption would be increased for zone 4 and decreased for zone 7. In addition, the number of hours with overheating risks would be increased under future climates, e.g. doubled in 2080, compared to the historical weather data. Therefore, efforts should be made in building design to take into account the impact of climate change to ensure buildings built today would perform as intended under changing climate.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3311
Author(s):  
Víctor Pérez-Andreu ◽  
Carolina Aparicio-Fernández ◽  
José-Luis Vivancos ◽  
Javier Cárcel-Carrasco

The number of buildings renovated following the introduction of European energy-efficiency policy represents a small number of buildings in Spain. So, the main Spanish building stock needs an urgent energy renovation. Using passive strategies is essential, and thermal characterization and predictive tests of the energy-efficiency improvements achieving acceptable levels of comfort for their users are urgently necessary. This study analyzes the energy performance and thermal comfort of the users in a typical Mediterranean dwelling house. A transient simulation has been used to acquire the scope of Spanish standards for its energy rehabilitation, taking into account standard comfort conditions. The work is based on thermal monitoring of the building and a numerical validated model developed in TRNSYS. Energy demands for different models have been calculated considering different passive constructive measures combined with real wind site conditions and the behavior of users related to natural ventilation. This methodology has given us the necessary information to decide the best solution in relation to energy demand and facility of implementation. The thermal comfort for different models is not directly related to energy demand and has allowed checking when and where the measures need to be done.


2021 ◽  
Vol 11 (9) ◽  
pp. 3972
Author(s):  
Azin Velashjerdi Farahani ◽  
Juha Jokisalo ◽  
Natalia Korhonen ◽  
Kirsti Jylhä ◽  
Kimmo Ruosteenoja ◽  
...  

The global average air temperature is increasing as a manifestation of climate change and more intense and frequent heatwaves are expected to be associated with this rise worldwide, including northern Europe. Summertime indoor conditions in residential buildings and the health of occupants are influenced by climate change, particularly if no mechanical cooling is used. The energy use of buildings contributes to climate change through greenhouse gas emissions. It is, therefore, necessary to analyze the effects of climate change on the overheating risk and energy demand of residential buildings and to assess the efficiency of various measures to alleviate the overheating. In this study, simulations of dynamic energy and indoor conditions in a new and an old apartment building are performed using two climate scenarios for southern Finland, one for average and the other for extreme weather conditions in 2050. The evaluated measures against overheating included orientations, blinds, site shading, window properties, openable windows, the split cooling unit, and the ventilation cooling and ventilation boost. In both buildings, the overheating risk is high in the current and projected future average climate and, in particular, during exceptionally hot summers. The indoor conditions are occasionally even injurious for the health of occupants. The openable windows and ventilation cooling with ventilation boost were effective in improving the indoor conditions, during both current and future average and extreme weather conditions. However, the split cooling unit installed in the living room was the only studied solution able to completely prevent overheating in all the spaces with a fairly small amount of extra energy usage.


2021 ◽  
Vol 16 (3) ◽  
pp. 155-177
Author(s):  
Shouib Mabdeh ◽  
Tamer Al Radaideh ◽  
Montaser Hiyari

ABSTRACT Thermal comfort has a great impact on occupants’ productivity and general well-being. Since people spend 80–90% of their time indoors, developing the tools and methods that enhance the thermal comfort for building are worth investigating. Previous studies have proved that using passive systems like Trombe walls and solar chimneys significantly enhanced thermal comfort in inside spaces despite that each system has a specific purpose within a specific climate condition. Hence, the main purpose of this study is to design and configure a new, dual functional passive system, called a solar wall. The new system combines the Trombe wall and solar chimney, and it can cool or heat based on building needs. Simulation software, DesignBuilder, has been used to configure the Solar Wall, and study its impact on indoor operative temperature for the base case. Using the new system, the simulation results were compared with those obtained in the base case and analyzed to determine the most efficient system design parameters and implementation method. The case that gave the best results for solar wall configuration was triple glazed glass and 0.1 cm copper as an absorber (case 11). The results show that using four units (case D) achieves longer thermal comfort levels: 15 to 24 thermal hours during winter (compared to five hours maximum) and 10 to 19 comfort hours in summer (compared to zero).