scholarly journals Effect of Hydrothermal Treatment with Distilled Water on Titanium Alloy for Epithelial Cellular Attachment

Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2748 ◽  
Author(s):  
Yasushige Sakamoto ◽  
Yasunori Ayukawa ◽  
Akihiro Furuhashi ◽  
Michimasa Kamo ◽  
Junji Ikeda ◽  
...  

The enhancement of oral epithelial adhesion to the trans-mucosal material of dental implants may improve their long-term stability. The aim of this study is to investigate whether hydrothermal treatment with distilled water (HT-DW) applied to a Ti-6Al-4V (Ti64) alloy could improve epithelial cellular attachment. We hypothesized that this treatment would enhance the adsorption of proteins and the adhesion of gingival epithelial GE1 cells. This treatment changed the surface crystal structure into an anatase type of titanium oxide without an apparent change of surface roughness or topography. Nitrogen was not detected on the HT-DW-treated Ti64, which indicates decontamination. HT-DW-treated Ti64 exhibited a hydrophilic surface with a less than 10° angle of water contact. Adsorption of laminin-332 to the HT-DW-treated Ti64 was significantly greater than that of the untreated Ti64 plates (64). The number of GE1 cells on the HT-DW-treated Ti64 at 1 and 3 days was significantly lower than that on 64; however, cell adhesion strength on HT-DW was greater, with a higher expression of integrin β4, compared with 64. This indicates that the HT-DW treatment of Ti64 improves the integration of GE1 cells, which might facilitate the development of a soft tissue barrier around the implant.

Materials ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3432
Author(s):  
Shumin Fan ◽  
Shuai Pei ◽  
Tianyu Shen ◽  
Guangri Xu ◽  
Yuanchao Li ◽  
...  

In this paper, a novel superhydrophobic magnetic sawdust (SMSD) was fabricated as an oil sorbent. The SMSD was functionalized with Fe3O4 nanoparticles using melamine formaldehyde resin (MFR) as a coupling agent and subsequently hydrophobically-treated with hexadecyltrimethoxysilane (HDTMS). The SMSD showed excellent superhydrophobicity with the water contact angle of 155.3 ± 0.9°. Meanwhile it had remarkable environmental durability, long-term stability, and mechanical durable properties. Taking advantage of its magnetic characteristics, the SMSD could be easily controlled to absorb oil to separate oil–water mixtures with high oil absorption capacity and good reusability. Moreover, the emulsion was successfully separated by SMSD, including water-in-oil and oil-in-water emulsions. This study developed an effective oil absorbent, which was low cost and environmentally-friendly.


2019 ◽  
Vol 2019 ◽  
pp. 1-8
Author(s):  
Junyong Chen ◽  
Junhui Xiang ◽  
Xian Yue ◽  
Huaxin Li ◽  
Xianbo Yu

Few cases of hydrophobic materials synthesized in water have been reported. In this work, water, as the only solvent, is used to prepare a superhydrophobic sponge via a facile and environment-friendly route. The as-prepared sponge, namely silylated polyvinyl alcohol (PVA) sponge, exhibits superhydrophobic and superoleophilic characters. It has the static water contact angle (WCA) of 152 ± 1 and the static oil contact angle (OCA) of 0°, which can lead to excellent selectivity for oil-water separation. Besides, the methyltriethoxysilane (MTES) can form a stable mixed structure with the PVA skeleton, resulting in the rare shedding of polymethylsiloxane nanoparticles and the long-term stability for oil-water separation. Furthermore, the silylated sponge shows a high separation efficiency (>99.6%), removing oil up to 6200∼14000 times of its own mass. The findings demonstrated that the silylated superhydrophobic sponge can be a promising candidate in water treatment application.


2016 ◽  
Vol 879 ◽  
pp. 1049-1052 ◽  
Author(s):  
Kensuke Kuroda ◽  
Masazumi Okido

Protein adsorption is considered to have a strong influence on the biological reactions of bone-substituting materials. However, the osteoconductivity of protein adsorbed Ti surface is not completely clear. In this study, we produced the protein adsorbed Ti implants using hydro-processing. The hydrothermal treatment in the distilled water gave the super-hydrophilic Ti surface and they had much protein adsorbability. Fibronectin or albumin was picked up as a protein, which was cell adhesive protein and not cell adhesive, respectively. And also, the content of the adsorbed protein was evaluated by FT-IR (ATR) analysis. The water contact angle influenced the amount of the adsorption of the protein and the osteoconductivity of the samples were evaluated by in vivo testing.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 610
Author(s):  
Cheonji Lee ◽  
Sunjong Oh ◽  
Seung-Chul Park ◽  
Ho-Nyun Lee ◽  
Hyun-Jong Kim ◽  
...  

Metal-oxide sensors, detect gas through the reaction of surface oxygen molecules with target gases, are promising for the detection of toxic pollutant gases, combustible gases, and organic vapors; however, their sensitivity, selectivity, and long-term stability limit practical applications. Porous structure for increasing surface area, adding catalyst, and altering the operation temperature are proposed for enhancing the sensitivity and selectivity. Although humidity can significantly affect the property and stability of the sensors, studies focusing on the long-term stability of gas sensors are scarce. To reduce the effects of humidity, 1H, 1H, 2H, 2H–perfluorooctyltriethoxysilane (PFOTS) was coated on a porous SnO2 film. The interconnected SnO2 nanowires improved the high surface area, and the PFOTS coating provided superhydrophobicity at water contact angle of 159°and perfect water vapor repellency inside E-SEM. The superhydrophobic porous morphology was maintained under relative humidity of 99% and operating temperature of 300 °C. The CO gas sensing of 5, 20, and 50 ppm were obtained with linearity at various humidity. Flame detection was also achieved with practical high humidity conditions. These results suggest the simple way for reliable sensing of nanostructured metal-oxide gas sensors with high sensitivity and long-term stability even in highly humid environments.


2005 ◽  
Vol 26 (2) ◽  
pp. 100-106 ◽  
Author(s):  
James D.A. Parker ◽  
Donald H. Saklofske ◽  
Laura M. Wood ◽  
Jennifer M. Eastabrook ◽  
Robyn N. Taylor

Abstract. The concept of emotional intelligence (EI) has attracted growing interest from researchers working in various fields. The present study examined the long-term stability (32 months) of EI-related abilities over the course of a major life transition (the transition from high school to university). During the first week of full-time study, a large group of undergraduates completed the EQ-i:Short; 32 months later a random subset of these students (N = 238), who had started their postsecondary education within 24 months of graduating from high school, completed the measures for a second time. The study found EI scores to be relatively stable over the 32-month time period. EI scores were also found to be significantly higher at Time 2; the overall pattern of change in EI-levels was more than can be attributed to the increased age of the participants.


1991 ◽  
Vol 65 (03) ◽  
pp. 263-267 ◽  
Author(s):  
A M H P van den Besselaar ◽  
R M Bertina

SummaryIn a collaborative trial of eleven laboratories which was performed mainly within the framework of the European Community Bureau of Reference (BCR), a second reference material for thromboplastin, rabbit, plain, was calibrated against its predecessor RBT/79. This second reference material (coded CRM 149R) has a mean International Sensitivity Index (ISI) of 1.343 with a standard error of the mean of 0.035. The standard error of the ISI was determined by combination of the standard errors of the ISI of RBT/79 and the slope of the calibration line in this trial.The BCR reference material for thromboplastin, human, plain (coded BCT/099) was also included in this trial for assessment of the long-term stability of the relationship with RBT/79. The results indicated that this relationship has not changed over a period of 8 years. The interlaboratory variation of the slope of the relationship between CRM 149R and RBT/79 was significantly lower than the variation of the slope of the relationship between BCT/099 and RBT/79. In addition to the manual technique, a semi-automatic coagulometer according to Schnitger & Gross was used to determine prothrombin times with CRM 149R. The mean ISI of CRM 149R was not affected by replacement of the manual technique by this particular coagulometer.Two lyophilized plasmas were included in this trial. The mean slope of relationship between RBT/79 and CRM 149R based on the two lyophilized plasmas was the same as the corresponding slope based on fresh plasmas. Tlowever, the mean slope of relationship between RBT/79 and BCT/099 based on the two lyophilized plasmas was 4.9% higher than the mean slope based on fresh plasmas. Thus, the use of these lyophilized plasmas induced a small but significant bias in the slope of relationship between these thromboplastins of different species.


1979 ◽  
Vol 42 (04) ◽  
pp. 1135-1140 ◽  
Author(s):  
G I C Ingram

SummaryThe International Reference Preparation of human brain thromboplastin coded 67/40 has been thought to show evidence of instability. The evidence is discussed and is not thought to be strong; but it is suggested that it would be wise to replace 67/40 with a new preparation of human brain, both for this reason and because 67/40 is in a form (like Thrombotest) in which few workers seem to use human brain. A �plain� preparation would be more appropriate; and a freeze-dried sample of BCT is recommended as the successor preparation. The opportunity should be taken also to replace the corresponding ox and rabbit preparations. In the collaborative study which would be required it would then be desirable to test in parallel the three old and the three new preparations. The relative sensitivities of the old preparations could be compared with those found in earlier studies to obtain further evidence on the stability of 67/40; if stability were confirmed, the new preparations should be calibrated against it, but if not, the new human material should receive a calibration constant of 1.0 and the new ox and rabbit materials calibrated against that.The types of evidence available for monitoring the long-term stability of a thromboplastin are discussed.


Sign in / Sign up

Export Citation Format

Share Document