scholarly journals Evaluation of the Surface Characteristics of Dental CAD/CAM Materials after Different Surface Treatments

Materials ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 981 ◽  
Author(s):  
Konstantinos Papadopoulos ◽  
Kimon Pahinis ◽  
Kyriaki Saltidou ◽  
Dimitrios Dionysopoulos ◽  
Effrosyni Tsitrou

Computer-aided design/computer-aided manufacturing (CAD/CAM) technology was developed to ensure the sufficient strength of tooth restorations, to improve esthetic restorations with a natural appearance and to make the techniques easier, faster and more accurate. In the view of the limited research on the surface treatments of the CAD/CAM materials and the need to evaluate the ideal surface characteristics of a material to achieve the best adhesion to tooth tissues, this study aimed to investigate the surface roughness and morphology of four different CAD/CAM materials using four different surface treatments. The CAD/CAM materials used in this study were three composites (Shofu Block HC, Lava Ultimate and Brilliant Crios) and a hybrid ceramic (Enamic). The surface of the specimens of each material received one of the following treatments: no surface treatment, sandblasting with 29 μm Al2O3 particles, 9% hydrofluoric acid etching and silane application, and the tribochemical method using CoJet System. Surface roughness was evaluated using optical profilometry, and surface morphology was observed by means of scanning electron microscopy. All surface treatments resulted in higher surface roughness values compared to the control group. Different treatments affected the surface properties of the materials, presumably due to discrepancies in their composition and structure.

2022 ◽  
Author(s):  
eaeldwakhly not provided

This study was conducted to assess the surface characteristics in terms of roughness of two CAD/CAM (Computer-Aided-Design/Computer-Aided Manufacturing)restorative material spre and post chewing simulation exposure. Methods: Specimens were prepared from two CAD/CAM ceramic materials: Cerec Blocs C and IPS e-max ZirCAD. A total of 10 disks were prepared for each study group. 3D optical noncontact surface profiler was used to test the surface roughness (ContourGT, Bruker, Campbell, CA, USA). A silicone mold was used to fix the individual samples using a self-curing resin. Surface roughness (SR) was examined pre and post exposure to chewing simulation. 480,000 simulated chewing cycles were conducted to mimic roughly two years of intraoral clinical service. The results data was first tested for normality and equal variance (Levene’s test >0.05) then examined with paired and independent sample t-test at a significance level of (p < 0.05). Results:The two CAD-CAM materials tested exhibited increased surface roughness from baseline. The highest mean surface roughness was observed in Cerec blocs C group after chewing simulation (2.34 µm± 0.62 µm). Whereas the lowest surface roughness was observed in IPS e.max ZirCAD group before chewing simulation (0.42 µm± 0.16 µm). Both study groups exhibited significantly different surface roughness values (p< 0.05). There was a statistically higher surface roughness values after the chewing simulation in Cerec blocs C when compared to IPS e.max ZirCAD groups (p = 0.000).Conclusion:Even though both tested CAD/CAM materials differ in recorded surface roughness values, results were within clinically accepted values.


2021 ◽  
Author(s):  
CA Jurado ◽  
A Tsujimoto ◽  
H Watanabe ◽  
NG Fischer ◽  
JA Hasslen ◽  
...  

SUMMARY Objective: The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. Method: Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All- Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. Results: All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. Conclusions: Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.


2019 ◽  
Vol 45 (4) ◽  
pp. 407-415 ◽  
Author(s):  
P Nassary Zadeh ◽  
N Lümkemann ◽  
M Eichberger ◽  
B Stawarczyk ◽  
M Kollmuss

Clinical Relevance As temporary materials are often used in prosthetic dentistry, there is need to investigate their behavior in the oral environment. Parameters such as surface roughness and surface free energy correlate to the level of plaque adhesion, which can impact gingival health. SUMMARY Objective: To test computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated and conventionally processed polymer-based temporary materials in terms of radiopacity (RO), surface free energy (SFE), surface roughness (SR), and plaque accumulation (PA). Methods and Materials: Six temporary materials (n=10/n=10) were tested, including three CAD/CAM-fabricated (CC) materials—Art Bloc Temp (CC-ABT), Telio CAD (CC-TC), and VITA CAD Temp (CC-VCT)—and three conventionally processed (cp) materials: Integrity Multi Cure (cp-IMC), Luxatemp Automix Plus (cp-LAP), and Protemp 4 (cp-PT4). Zirconia acted as the control group (CG, n=10). RO was evaluated according to DIN EN ISO 13116. SFE was investigated using contact angle measurements. SR was measured using a profilometer. The PA tests were performed using three microorganisms: Streptococcus mutans, Actinomyces naeslundii, and Veillonella parvula. Data were analyzed using Kolmogorov-Smirnov, Kruskal-Wallis, Mann-Whitney U-, Dunn-Bonferroni, Wilcoxon, Levene, and Pearson tests and one-way analysis of variance with post hoc Scheffé test (α=0.05). Results: No radiopacity was observed for any CC material or cp-PT4. CG showed the highest RO, while no differences between cp-IMC and cp-LAP were found. CG showed lower SFE compared to all polymer temporary materials, except in the case of CC-TC. cp-LAP and cp-IMC presented higher SFE than did CC-TC and CG. CC-ABT presented lower initial SR values compared to cp-PT4 and cp-LAP. For cp-LAP, a higher initial SR was measured than for all CAD/CAM materials and cp-IMC. All specimens showed a certain amount of PA after the incubation period. A naeslundii and V parvula resulted in comparable PA values, whereas the values for S mutans were lower by one log level. CAD/CAM materials showed superior results for SR, SFE, and PA, whereas all materials lacked RO.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Afnan Alfouzan ◽  
Alhanouf Alnouwaisar ◽  
Njood Alazzam ◽  
Hanan AL-Otaibi ◽  
Nawaf Labban ◽  
...  

Abstract Oral dentures are subjected to mechanical and chemical cleansing processes. However, these processes alter the physical and mechanical properties of denture acrylic resins. This study analyzes the surface roughness of conventional heat-cured (HC) polymethacrylate, light-cured (LC) urethane dimethacrylate, and prepolymerized computer-aided design/computer-aided manufacturing (CAD/CAM) dental acrylic resins. The materials were subjected to combined surface treatment of mechanical brushing, thermal cycling, and immersion in chemical disinfectants (corega, chlorhexidine gluconate [CHG], and sodium hypochlorite) to simulate 1 year of clinical use. The surface roughness of the resin specimens before and after surface treatment was evaluated using a noncontact profilometer. Statistical tests based on analysis of variance revealed significant interactions between resin type and disinfectants, indicating that the effects of these two factors were interdependent. The highest and lowest surface roughness was observed in HC resins immersed in CHG and CAD/CAM resins immersed in sodium hypochlorite. Among the materials, HC resins demonstrated the overall highest mean roughness, followed by LC and CAD/CAM resins. Regarding the disinfectant use, the highest mean roughness was observed in disks immersed in CHG, followed by those immersed in corega and sodium hypochlorite. The prepolymerized CAD/CAM acrylic resin demonstrated superior surface quality following combined surface treatments. The HC and LC resins exceeded the roughness threshold and the reported roughness values for acrylic resins following surface treatments. Among the disinfectants tested, sodium hypochlorite produced overall low roughness values.


2021 ◽  
Vol 19 ◽  
pp. 228080002110588
Author(s):  
Sarah S. Al-Angari ◽  
Shahad Meaigel ◽  
Nouf Almayouf ◽  
Shahad Quwayhis ◽  
Abdulelah Aldahash ◽  
...  

Objectives: To investigate the effects of a coffee beverage and two whitening systems on the surface roughness and gloss of glazed Lithium Disilicate Glass-Ceramics (LDGC) for computer-aided design/computer-aided manufacturing (CAD/CAM) systems. Methods: Sixty-eight LDGC disks (12 × 10 × 2 mm) were prepared from blocks of CAD/CAM systems (IPS e.max CAD ceramic). Baseline measurements for surface roughness (Ra) and gloss (GU) were taken using a 3-D optical profilometer and a glossmeter, respectively; then specimens were randomized into four groups ( n = 17). All specimens were immersed in a coffee solution (24 h × 12 days) then subjected to two whitening systems. G1-negative control (kept moist × 7 days); G2-positive control (brushed with distilled water, 200 g/load, 2 min twice daily × 7 days); G3-whitening toothpaste (Colgate optic white; relative dentin abrasivity (RDA) = 100, 200 g/load, 2 min twice daily × 7 days); and G4-simulated at-home bleaching protocol (Opalescence,15% carbamide peroxide (CP), 6 h/day × 7 days). The study outcomes were measured at baseline and after the treatments. Data were analyzed using paired T-test and one-way ANOVA (α = 0.05). Results: The mean surface roughness significantly increased ( p ⩽ 0.002) for all groups after the designated treatment protocols. Among groups, the mean surface roughness of G2 and G3 were significantly higher ( p ⩽ 0.001) (Ra: 0.51 and 0.57 μm, respectively) compared to the control group (Ra: 0.23 μm), and were not significantly different from G4 (Ra: 0.46 μm). Surface gloss decreased with no significant change within or among groups after treatment. Conclusion: All glazed LDGC had a significant increase in surface roughness after being subjected to simulated 1 year of coffee drinking and whitening systems (15% CP and whitening toothpaste), and the greatest change was associated with brushing (simulating 8 months). However, coffee beverages and whitening systems had no significant effect on the surface gloss.


2019 ◽  
Vol 09 (02) ◽  
pp. 57-63
Author(s):  
Sushmita V. Palanisamy ◽  
Chethan Hegde

Abstract Background Contemporary dentistry is advancing toward computer-aided design/ computer-aided manufacturing (CAD/CAM) technology. But the budding dentists are unaware about the advancement. This survey aims at detecting the level of awareness among the undergraduate students and then correlating those results to modify the future curriculum. Objective The study aims (1) to assess the awareness among the dental undergraduate students and (2) to correlate the level of awareness among the third years, final years, and interns. Sample Selection Study sample consist of 300 students (third year students, final year students, and interns) of A. B. Shetty Memorial Institute of Dental Sciences, Mangalore, Karnataka, India. The information of the survey was collected with the help of a questionnaire. Results More than 70% of the students were aware about the basic functioning of CAD/CAM unit and approximately 74% of the students were unaware about the materials used to fabricate the prosthesis using CAD/CAM technology.


Materials ◽  
2019 ◽  
Vol 12 (14) ◽  
pp. 2252 ◽  
Author(s):  
Yin ◽  
Jang ◽  
Lee ◽  
Bae

This study compares the mechanical properties and wear ability of five CAD/CAM (computer-aided design/computer-aided manufacturing) millable dental blocks. All the discs, including Amber Mill Hybrid, Vita Enamic, Katana Avencia, Lava Ultimate, and Amber Mill, were cut in dimensions of 1.2 mm in thickness and 12 mm in diameter, polished to a machined surface, and immersed in distilled water for seven days. Vickers hardness was measured and the indentations were observed using microscope. The discs were brushed under a 150 g load. Mean surface roughness (Ra) and topography were determined after 100,000 cycles. Finally the biaxial flexure strength of the discs was measured and the broken surfaces were observed using scanning electron microscopy (SEM). The data was subjected to Weibull analysis. All data were analyzed by one-way analysis (ANOVA). The results of Vickers hardness are shown as: Amber Mill > Vita Enamic > Amber Mill Hybrid > Lava Ultimate > Katana Avencia. Katana Avencia showed the highest volume percentage reduction and the roughest surface after toothbrushing. The biaxial flexural strength is shown as: Amber Mill > Katana Avencia > Lava Ultimate > Amber Mill Hybrid > Vita Enamic. All the tested materials exhibited varying degrees of mass loss and surface roughness. The properties of the composite materials are related to the filler content, filler volume, and polymerization methods.


2018 ◽  
Vol 43 (4) ◽  
pp. 437-446 ◽  
Author(s):  
NG Fischer ◽  
A Tsujimoto ◽  
AG Baruth

SUMMARY Objective: Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. Purpose: To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. Methods: One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. Results: AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. Conclusions: These in vitro results suggest changes in OP Ra due to bur reuse and polishing application force. Within the parameters of this study, the resultant topography of zirconia polishing is force-dependent and the reuse of coarse polishing burs is possible without statistically significant differences in Ra values after initial use. Nanoscale and microscale topography were shown to depend on specific polishing bur type.


2019 ◽  
Vol 17 (1) ◽  
pp. 228080001880710 ◽  
Author(s):  
İbrahim Duran ◽  
Necati Kaleli ◽  
Çağrı Ural ◽  
İdris Kavut

Background: This in vitro study aimed to evaluate the amount of polymerizing light passing through hybrid ceramic specimens in different shades and thicknesses. Methods: Rectangular-shaped feldspathic ceramic computer aided design and computer aided manufacturing (CAD-CAM) blocks and translucent and high translucent polymer infiltrated hybrid ceramic CAD-CAM blocks in four different shades (1M1, 1M2, 2M2, and 3M2) were sectioned in four different thicknesses (0.8, 1.5, 2, and 3 mm), and a total of 48 groups ( n = 10) were obtained. Feldspathic ceramic specimens served as the control group. The light transmission of each ceramic specimen was measured three times by using a light-emitting diode and a radiometer. Data were statistically analyzed by using univariate analysis of variance (ANOVA) followed by one-way ANOVA, Tukey honest significant difference, and Tamhane T2 tests (α = 0.05). Results: Translucent polymer infiltrated hybrid ceramic specimens exhibited significantly ( p < 0.001) lower light transmission values than high translucent polymer infiltrated hybrid ceramic and feldspathic ceramic specimens, whereas feldspathic ceramic specimens exhibited significantly ( p < 0.001) higher light transmission than translucent and high translucent polymer infiltrated hybrid ceramic specimens. The amount of light transmission significantly ( p < 0.05) decreased when the shade value decreased and the thickness increased. Conclusions: Polymer infiltrated hybrid ceramic specimens showed lower light transmission values than feldspathic ceramic specimens, and the amount of light transmission was affected by the ceramic shade and thickness.


Sign in / Sign up

Export Citation Format

Share Document