scholarly journals Correlation between the Perfusion Index and Intraoperative Hypothermia: A Prospective Observational Pilot Study

Medicina ◽  
2021 ◽  
Vol 57 (4) ◽  
pp. 364
Author(s):  
Sangho Lee ◽  
Keon-Sik Kim ◽  
Sung-Wook Park ◽  
Ann-Hee You ◽  
Sang-Wook Lee ◽  
...  

Background and Objectives: We examined the association between the baseline perfusion index (PI) and changes in intraoperative body temperature during general anesthesia. The PI reflects the peripheral perfusion state. The PI may be associated with changes in body temperature during general anesthesia because the degree of redistribution of body heat from the central to the peripheral compartment varies depending on the peripheral perfusion state. Materials and Methods: Thirty-eight patients who underwent brain surgery were enrolled in this study. The baseline PI and body temperature of the patients were measured on entering the operating room. Body temperature was recorded every 15 min after induction of anesthesia using an esophageal temperature probe. Univariate and multivariate logistic regression analyses were performed to identify the risk factors for intraoperative hypothermia. Results: Eighteen patients (47 %) developed hypothermia intraoperatively. The baseline PI was significantly lower among patients in the hypothermia group (1.8 ± 0.7) than among those in the normothermia group (3.0 ± 1.2) (P < 0.001). The baseline PI and body temperature were independently associated with intraoperative hypothermia (PI: odds ratio [OR], 0.270; 95% confidence interval [CI], 0.105–0.697; P = 0.007, baseline body temperature: OR, 0.061; 95% CI, 0.005–0.743; P = 0.028). Conclusions: This study showed that low baseline PI was the factor most related to the development of intraoperative hypothermia. Future studies should consider the PI as a predictor of intraoperative hypothermia.

2008 ◽  
Vol 109 (2) ◽  
pp. 318-338 ◽  
Author(s):  
Daniel I. Sessler ◽  
David S. Warner ◽  
Mark A. Warner

Most clinically available thermometers accurately report the temperature of whatever tissue is being measured. The difficulty is that no reliably core-temperature-measuring sites are completely noninvasive and easy to use-especially in patients not undergoing general anesthesia. Nonetheless, temperature can be reliably measured in most patients. Body temperature should be measured in patients undergoing general anesthesia exceeding 30 min in duration and in patients undergoing major operations during neuraxial anesthesia. Core body temperature is normally tightly regulated. All general anesthetics produce a profound dose-dependent reduction in the core temperature, triggering cold defenses, including arteriovenous shunt vasoconstriction and shivering. Anesthetic-induced impairment of normal thermoregulatory control, with the resulting core-to-peripheral redistribution of body heat, is the primary cause of hypothermia in most patients. Neuraxial anesthesia also impairs thermoregulatory control, although to a lesser extent than does general anesthesia. Prolonged epidural analgesia is associated with hyperthermia whose cause remains unknown.


Medicina ◽  
2021 ◽  
Vol 57 (11) ◽  
pp. 1255
Author(s):  
Cheol Lee ◽  
SeongNam Park ◽  
ByoungRyun Kim ◽  
Hyeonbin Yim ◽  
Myeongjong Lee ◽  
...  

Background and Objectives: Female reproductive hormones may affect core body temperature. This study aimed to investigate the effects of female reproductive hormones on inadvertent intraoperative hypothermia in patients who underwent laparoscopic gynecologic surgery under general anesthesia. Materials and Methods: This retrospective study included 660 menstruating and menopausal female patients aged 19–65 years. The patients were divided into two groups according to the occurrence of inadvertent intraoperative hypothermia: non-hypothermia group (N = 472) and hypothermia group (N = 188). After propensity score matching, 312 patients (N = 156 in each group) were analyzed to investigate the association between intraoperative hypothermia and female reproductive hormones. As potential predictors of inadvertent hypothermia, the levels of female reproductive hormones were analyzed using binary logistic regression. Results: The association of estradiol (r = −0.218, p = 0.000) and progesterone (r = −0.235, p = 0.000) levels with inadvertent intraoperative hypothermia was significant but weakly negative before matching; however, it was significant and moderately negative after matching (r = −0.326, p = 0.000 and r = −0.485, p = 0.000, respectively). In a binary logistic analysis, the odds ratio for estradiol was 0.995 (p = 0.014, 0.993 < 95% confidence interval [CI] < 0.998) before matching and 0.993 (p = 0.000, 0.862 < 95% CI < 0.930) after matching, and that for progesterone was 0.895 (p = 0.000, 0.862 < 95% CI < 0.930) before matching and 0.833 (p = 0.014, 0.990 < 95% CI < 0.996) after matching. Conclusions: Estradiol and progesterone levels were associated with inadvertent intraoperative hypothermia. However, the odds ratio for female reproductive hormone levels was close to 1. Therefore, female reproductive hormones may not be a risk factor for hypothermia during gynecologic surgery under general anesthesia. However, a small sample size in this study limits the generalizability of the results.


2021 ◽  
Vol 22 ◽  
pp. 100152
Author(s):  
Ahmad khaled Abubaker ◽  
Haya Yacoub Alul ◽  
Isam K. Bsisu ◽  
Daher K. Rabadi ◽  
Ismail Ragab AbuAlsha'r ◽  
...  

Animals ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 1388
Author(s):  
Ted Friend ◽  
Giulia Corsini ◽  
Vincent Manero ◽  
Raffaella Cocco

The documentation of diurnal patterns in body temperature in lions could be important because disruption of circadian patterns can be a useful measure of distress. This study quantified changes in body temperature of seven African lions (Panthera leo) at 5 min intervals during cold conditions from noon until the ingested body temperature loggers were expelled the next day. Thirteen loggers were fed to 11 lions during their daily noon feeding, while ambient temperatures were also recorded using six data loggers. The lions had continuous access to their dens and exercise pens during the day but were restricted to their heavily bedded dens that also contained a heat lamp from 23:00 until 08:00 the next day. Body temperatures averaged 37.95 ± 0.42 °C at 15:50, and 36.81 ± 0.17 °C at 06:50 the next day, 30 min before the first loggers passed from a lion, and were significantly different (t-test, t = 8.09, df = 6, p < 0.0003). The mean duration for the time of passage was 22 ± 2.69 (h ± SD), so future studies using the noninvasive feeding of temperature loggers need to consider that time frame.


2012 ◽  
Vol 47 (2) ◽  
pp. 184-190 ◽  
Author(s):  
Masaki Iguchi ◽  
Andrew E. Littmann ◽  
Shuo-Hsiu Chang ◽  
Lydia A. Wester ◽  
Jane S. Knipper ◽  
...  

Context: Conditions such as osteoarthritis, obesity, and spinal cord injury limit the ability of patients to exercise, preventing them from experiencing many well-documented physiologic stressors. Recent evidence indicates that some of these stressors might derive from exercise-induced body temperature increases. Objective: To determine whether whole-body heat stress without exercise triggers cardiovascular, hormonal, and extra-cellular protein responses of exercise. Design: Randomized controlled trial. Setting: University research laboratory. Patients or Other Participants: Twenty-five young, healthy adults (13 men, 12 women; age = 22.1 ± 2.4 years, height = 175.2 ± 11.6 cm, mass = 69.4 ± 14.8 kg, body mass index = 22.6 ± 4.0) volunteered. Intervention(s): Participants sat in a heat stress chamber with heat (73°C) and without heat (26°C) stress for 30 minutes on separate days. We obtained blood samples from a subset of 13 participants (7 men, 6 women) before and after exposure to heat stress. Main Outcome Measure(s): Extracellular heat shock protein (HSP72) and catecholamine plasma concentration, heart rate, blood pressure, and heat perception. Results: After 30 minutes of heat stress, body temperature measured via rectal sensor increased by 0.8°C. Heart rate increased linearly to 131.4 ± 22.4 beats per minute (F6,24 = 186, P &lt; .001) and systolic and diastolic blood pressure decreased by 16 mm Hg (F6,24 = 10.1, P &lt; .001) and 5 mm Hg (F6,24 = 5.4, P &lt; .001), respectively. Norepinephrine (F1,12 = 12.1, P = .004) and prolactin (F1,12 = 30.2, P &lt; .001) increased in the plasma (58% and 285%, respectively) (P &lt; .05). The HSP72 (F1,12 = 44.7, P &lt; .001) level increased with heat stress by 48.7% ± 53.9%. No cardiovascular or blood variables showed changes during the control trials (quiet sitting in the heat chamber with no heat stress), resulting in differences between heat and control trials. Conclusions: We found that whole-body heat stress triggers some of the physiologic responses observed with exercise. Future studies are necessary to investigate whether carefully prescribed heat stress constitutes a method to augment or supplement exercise.


2021 ◽  
Vol 5 (3) ◽  
pp. 543-549
Author(s):  
Helmy Yudhistira Putra ◽  
Utomo Budiyanto

During the COVID-19 pandemic, the price of preventive equipment such as masks and hand sanitizers has increased significantly. Likewise, thermometers are experiencing an increase and scarcity, this tool is also sought after by many companies for screening employees and guests before entering the building to detect body temperatures that are suspected of being positive for COVID-19. The use of a thermometer operated by humans is very risky because dealing directly with people who could be ODP (People Under Monitoring/Suscpected ) or even positive for COVID-19, therefore we need tools for automatic body temperature screening and do not involve humans for the examination. This research uses the MLX-90614 body temperature sensor equipped with an ultrasonic support sensor to detect movement and measure the distance between the forehead and the temperature sensor so that the body heat measurement works optimally, and a 16x2 LCD to display the temperature measurement results. If the measured body temperature is more than 37.5 ° C degrees Celsius then the buzzer will turn on and the selenoid door lock will not open and will send a notification to the Telegram messaging application. The final result obtained is the formation of a prototype device for measuring body temperature automatically without the need to involve humans in measuring body temperature to control people who want to enter the building so as to reduce the risk of COVID-19 transmission


1998 ◽  
Vol 88 (6) ◽  
pp. 1511-1518 ◽  
Author(s):  
Angela Rajek ◽  
Rainer Lenhardt ◽  
Daniel I. Sessler ◽  
Andrea Kurz ◽  
Gunther Laufer ◽  
...  

Background Afterdrop following cardiopulmonary bypass results from redistribution of body heat to inadequately warmed peripheral tissues. However, the distribution of heat between the thermal compartments and the extent to which core-to-peripheral redistribution contributes to post-bypass hypothermia remains unknown. Methods Patients were cooled during cardiopulmonary bypass to nasopharyngeal temperatures near 31 degrees C (n=8) or 27 degrees C (n=8) and subsequently rewarmed by the bypass heat exchanger to approximately 37.5 degrees C. A nasopharyngeal probe evaluated core (trunk and head) temperature and heat content. Peripheral compartment (arm and leg) temperature and heat content were estimated using fourth-order regressions and integration over volume from 19 intramuscular needle thermocouples, 10 skin temperatures, and "deep" foot temperature. Results In the 31 degrees C group, the average peripheral tissue temperature decreased to 31.9+/-1.4 degrees C (means+/-SD) and subsequently increased to 34+/-1.4 degrees C at the end of bypass. The core-to-peripheral tissue temperature gradient was 3.5+/-1.8 degrees C at the end of rewarming, and the afterdrop was 1.5+/-0.4 degrees C. Total body heat content decreased 231+/-93 kcal. During pump rewarming, the peripheral heat content increased to 7+/-27 kcal below precooling values, whereas the core heat content increased to 94+/-33 kcal above precooling values. Body heat content at the end of rewarming was thus 87+/-42 kcal more than at the onset of cooling. In the 27 degrees C group, the average peripheral tissue temperature decreased to a minimum of 29.8 +/-1.7 degrees C and subsequently increased to 32.8+/-2.1 degrees C at the end of bypass. The core-to-peripheral tissue temperature gradient was 4.6+/-1.9 degrees C at the end of rewarming, and the afterdrop was 2.3+/-0.9 degrees C. Total body heat content decreased 419+/-49 kcal. During pump rewarming, core heat content increased to 66+/-23 kcal above precooling values, whereas peripheral heat content remained 70+/-42 kcal below precooling values. Body heat content at the end of rewarming was thus 4+/-52 kcal less than at the onset of cooling. Conclusions Peripheral tissues failed to fully rewarm by the end of bypass in the patients in the 27 degrees C group, and the afterdrop was 2.3+/-0.9 degrees C. Peripheral tissues rewarmed better in the patients in the 31 degrees C group, and the afterdrop was only 1.5+/-0.4 degrees C.


2012 ◽  
Vol 20 (1) ◽  
pp. 183-191 ◽  
Author(s):  
Vanessa de Brito Poveda ◽  
Edson Zangiacomi Martinez ◽  
Cristina Maria Galvão

This study analyzed the evidence available in the literature concerning the effectiveness of different active cutaneous warming systems to prevent intraoperative hypothermia. This is a systematic review with primary studies found in the following databases: CINAHL, EMBASE, Cochrane Register of Controlled Trials and Medline. The sample comprised 23 randomized controlled trials. There is evidence in the literature indicating that the circulating water garment system is the most effective in maintaining patient body temperature. These results can support nurses in the decision-making process concerning the implementation of effective measures to maintain normothermia, though the decision of health services concerning which system to choose should also take into account its cost-benefit status given the cost related to the acquisition of such systems.


Sign in / Sign up

Export Citation Format