Rancang Bangun Pengukur Suhu Tubuh Dengan Multi Sensor Untuk Mencegah Penyebaran Covid-19

2021 ◽  
Vol 5 (3) ◽  
pp. 543-549
Author(s):  
Helmy Yudhistira Putra ◽  
Utomo Budiyanto

During the COVID-19 pandemic, the price of preventive equipment such as masks and hand sanitizers has increased significantly. Likewise, thermometers are experiencing an increase and scarcity, this tool is also sought after by many companies for screening employees and guests before entering the building to detect body temperatures that are suspected of being positive for COVID-19. The use of a thermometer operated by humans is very risky because dealing directly with people who could be ODP (People Under Monitoring/Suscpected ) or even positive for COVID-19, therefore we need tools for automatic body temperature screening and do not involve humans for the examination. This research uses the MLX-90614 body temperature sensor equipped with an ultrasonic support sensor to detect movement and measure the distance between the forehead and the temperature sensor so that the body heat measurement works optimally, and a 16x2 LCD to display the temperature measurement results. If the measured body temperature is more than 37.5 ° C degrees Celsius then the buzzer will turn on and the selenoid door lock will not open and will send a notification to the Telegram messaging application. The final result obtained is the formation of a prototype device for measuring body temperature automatically without the need to involve humans in measuring body temperature to control people who want to enter the building so as to reduce the risk of COVID-19 transmission

Author(s):  
Musyahadah Arum Pertiwi ◽  
I Dewa Gede Hari Wisana ◽  
Triwiyanto Triwiyanto ◽  
Sasivimon Sukaphat

Heart rate and body temperature can be used to determine the vital signs of humans. Heart rate and body temperature are two important parameters used by paramedics to determine the physical health condition and mental condition of a person. Because if your heart rate or body temperature is not normal then you need to make further efforts to avoid things that are not desirable. The purpose of this study is to design a heart rate and body temperature. In this study, the heart rate is detected using a finger sensor which placed on the finger. This sensor detects the heart rate pulses through infrared absorption of blood hemoglobin, and measure the body temperature using a DS18B20 temperature sensor which is placed axially. DS18B20 sensor works by converting temperature into digital data. The measurement results will be displayed on liquid crystal display (LCD) 2 x 16 and the data will be sent to android mobile phone via Bluetooth.  After the comparision beetwen the desain and the standart, the error is 0.46% for beats per minutes (BPM) parameters and 0.31 degrees Celsius for temperature parameters.


2021 ◽  
Vol 1 (1) ◽  
Author(s):  
Wahyu ja’far siddiq ◽  
Indah sulistiyowati

The Covid-19 pandemic that is currently spreading in Indonesia has claimed thousands of lives. Coronavirus Disease is characterized by the main clinical symptoms of fever >38 °C, coughing, to shortness of breath. In preventing its spread, the government conducts early detection by examining the main symptoms in the form of a fever and enforcing health protocols on each line. Therefore, we need an appropriate innovation that can make it easier for officers/guards to check human body temperature, especially in crowded places such as at airports, malls, or on the highway. Currently, body temperature measurement equipment is widely used, which allegedly made many errors in detecting it. Therefore, an innovative helmet was created that can be used by guards, security and even the police to detect body temperature based on the Arduino Pro Mini with the MLX90614-DCI sensor and the output is the real body temperature displayed on the LED screen. When the body temperature reads more than 38 °C, the helmet will turn on a buzzer and an LED to show that the target measurement is in a fever condition, and it is recommended going to the health center for further examination. This tool has been tested, and the sensor readings have an accuracy at a distance of 100 cm with several participants and the sensor readings are compared with the reading values from the alpha one thermometer and the measurement results have an accuracy level of 95%.


2019 ◽  
Vol 97 (Supplement_3) ◽  
pp. 463-464
Author(s):  
jorge L Vilela ◽  
Jorge Ascue ◽  
Milagros Callan ◽  
Gianella Goycochea ◽  
Andrea Jauregui ◽  
...  

Abstract The temperature measurement is essential during the physical examination since it helps to detect abnormalities on animal health. In addition, it should be done in the shortest possible time to avoid stress. The objective of this research is to calculate the correlation between rectal temperature and the superficial body temperature by means of a digital infrared thermometer. Ten alpacas huacaya from the center of development Alpaquero (CEDAT-DESCOSUR), located in Arequipa region at 4,365 m.a.s.l, and eight alpacas huacaya of the zootechnical and technological unit (UZYT) of the Universidad Cientifica del Sur, located in Lima at 0 m.a.s.l., were used. Rectal temperature measurement (RECTAL) was done with a veterinary clinical thermometer for one minute. Superficial body temperature measurement was conducted with infrared thermometer model CENTER 350®, at a distance of between 20 to 25 cm. Six measuring points were established by infrared thermometer: the outer zone of the nose (ON), the inner zone of the nose (IN), the extreme zone of ear (EE), middle zone of ear (ME), lower zone of the ear (LE) and the belly of the animal (BE). Rectal temperatures were measured at the same time as superficial body temperatures. Pearson’s correlation coefficient and graphs were calculated using an R software package called “CORRGRAM.” The results are presented in Table 1. Mean and deviation standard for rectal temperature from CEDAT-DESCOSUR and UZYT were 38.03 ± 0.37 and 37.46 ± 0.35 ° C, respectively. The results showed that there is a major correlation between rectal temperature and the temperature of the middle of the ear and the outer zone of the nose. In conclusion, there is a highly significant correlation between rectal temperature and superficial body temperature in some areas of the body, being an alternative option for the prediction of temperature in alpacas.


2015 ◽  
Vol 36 (6Supl2) ◽  
pp. 4575
Author(s):  
Julyana Machado da Silva Martins ◽  
Evandro De Abreu Fernandes ◽  
João Paulo Rodrigues Bueno ◽  
Carolina Magalhães Caires Carvalho ◽  
Fernanda Heloisa Litz ◽  
...  

<p>The objective of this study was to evaluate the effect of different nutritional plans on the body temperature and organ biometrics in male and female broilers, of two ages. Here, 1,700 birds were used (850 males and 850 females) in a completely randomized design composed of five treatments (- 3%, - 1.5%, reference, + 1.5% and + 3%), with 10 repetitions, totaling 50 experimental units; the reference treatment based on nutritional and energy levels indicated in previous studies was calculated from this. At 35 and 42 d, the temperatures of the wing, head, shin, back, and cloaca in males and females were measured separately, and the average surface and body temperature were calculated. At 42 d, relative weights of the gizzard, liver, heart, and small intestine were calculated. The temperatures of the wings, back, and cloaca, and consequently the average surface temperature and body temperatures, were not affected by nutritional plans. Effects of increasing the nutritional and energy levels were observed on liver weights, the gizzard, and the small intestine. We conclude that the nutritional plans did not affect body temperature. Males had higher body temperatures than females. Body temperature increased with increase in age, and the increase in the nutritional plans increased liver weight and reduced the gizzard weights.</p>


PeerJ ◽  
2018 ◽  
Vol 6 ◽  
pp. e4698 ◽  
Author(s):  
David R. Daversa ◽  
Camino Monsalve-Carcaño ◽  
Luis M. Carrascal ◽  
Jaime Bosch

Risks of parasitism vary over time, with infection prevalence often fluctuating with seasonal changes in the annual cycle. Identifying the biological mechanisms underlying seasonality in infection can enable better prediction and prevention of future infection peaks. Obtaining longitudinal data on individual infections and traits across seasons throughout the annual cycle is perhaps the most effective means of achieving this aim, yet few studies have obtained such information for wildlife. Here, we tracked spiny common toads (Bufo spinosus) within and across annual cycles to assess seasonal variation in movement, body temperatures and infection from the fungal parasite, Batrachochytrium dendrobatidis (Bd). Across annual cycles, toads did not consistently sustain infections but instead gained and lost infections from year to year. Radio-tracking showed that infected toads lose infections during post-breeding migrations, and no toads contracted infection following migration, which may be one explanation for the inter-annual variability in Bd infections. We also found pronounced seasonal variation in toad body temperatures. Body temperatures approached 0 °C during winter hibernation but remained largely within the thermal tolerance range of Bd. These findings provide direct documentation of migratory recovery (i.e., loss of infection during migration) and escape in a wild population. The body temperature reductions that we observed during hibernation warrant further consideration into the role that this period plays in seasonal Bd dynamics.


1959 ◽  
Vol 14 (5) ◽  
pp. 785-788
Author(s):  
R. G. Bartlett ◽  
P. D. Altland

A comparison of the altitude tolerance of restrained and nonrestrained adult male (225–300 gm) and adult female (150–225 gm) Sprague-Dawley rats exposed to an altitude of 33,500 ft. at various rates of ascent with various prealtitude exposure treatments was made. Animals restrained immediately before altitude exposure with rapid ascent (2000 ft/min) to altitude die significantly sooner than do nonrestrained control animals. Slow stepwise ascent to altitude (2 ½ –4 hr. to reach terminal altitude) increased the altitude tolerance of both the restrained and nonrestrained animals but much more for the restrained animals. When body temperatures were dropped to 25℃ before altitude exposure there were no deaths (up to 6 hr.) in either the restrained or nonrestrained animals. A lesser body temperature fall provided less protection. It appears that restraint may affect altitude tolerance in the rat by hastening the body temperature fall ordinarily associated with altitude exposure and by increasing the oxygen requirements as a result of the struggling to escape restraint. Since the former increases altitude tolerance and the latter reduces it, restraint may significantly increase or significantly decrease altitude tolerance, depending on the experimental procedure. Submitted on March 4, 1959


1974 ◽  
Vol 22 (3) ◽  
pp. 319 ◽  
Author(s):  
HG Cogger

A field study of the thermal relationships of the small agamid lizard A. fordi has been carried out in two areas of mallee in central western New South Wales, where this lizard occurs only in close association with the grass Triodia scariosa. The body temperatures characteristic of various phases in this lizard's die1 cycle have been determined. The behavioural techniques employed to regulate temperature are described; they are similar to those used by a wide range of diurnal heliothermic lizards in other regions. The total effect of these thermoregulatory responses is to maintain an internal thermal environ- ment approaching homoiothermy while the lizard is active. For A. fordi the eccritic body temperature determined from animals in the field is 36.9+-0.16C. Lowering of activity thermal levels occurs in winter, and can be induced at any time by even mild starvation.


1960 ◽  
Vol 11 (5) ◽  
pp. 871 ◽  
Author(s):  
DF Dowling

An experiment was performed to test the effect of solar radiation on the body temperatures of cattle, both clipped and with hair coat, in a clear transparent plastic covering as compared with cattle in a white reflective plastic covering. The mean body temperature of the animals in white plastic coats was 0.15°F lower than that of animals in clear plastic coats. This difference was highly significant statistically (P< 0.001). Animals in both clear and white coats had higher body temperatures than controls without plastic coats. The difference was highly significant, and was about 1.5°F in the clipped animals.


2017 ◽  
Vol 4 (12) ◽  
pp. 171359 ◽  
Author(s):  
M. Teague O'Mara ◽  
Sebastian Rikker ◽  
Martin Wikelski ◽  
Andries Ter Maat ◽  
Henry S. Pollock ◽  
...  

Reduction in metabolic rate and body temperature is a common strategy for small endotherms to save energy. The daily reduction in metabolic rate and heterothermy, or torpor, is particularly pronounced in regions with a large variation in daily ambient temperature. This applies most strongly in temperate bat species (order Chiroptera), but it is less clear how tropical bats save energy if ambient temperatures remain high. However, many subtropical and tropical species use some daily heterothermy on cool days. We recorded the heart rate and the body temperature of free-ranging Pallas' mastiff bats ( Molossus molossus ) in Gamboa, Panamá, and showed that these individuals have low field metabolic rates across a wide range of body temperatures that conform to high ambient temperature. Importantly, low metabolic rates in controlled respirometry trials were best predicted by heart rate, and not body temperature . Molossus molossus enter torpor-like states characterized by low metabolic rate and heart rates at body temperatures of 32°C, and thermoconform across a range of temperatures. Flexible metabolic strategies may be far more common in tropical endotherms than currently known.


2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. S631-S631
Author(s):  
Ivayla I Geneva ◽  
Waleed Javaid

Abstract Background The circadian rhythm is believed to offer survival advantage with dysregulation being linked to immune response deficiencies and metabolic derangements. Diurnal temperature variation exists in humans, yet its preservation during illness is not well understood. Herein we present an analysis of diurnal body temperatures among hospitalized patients, with a focus on infectious versus non-infectious diagnoses. Methods Temperatures measured within 1/2 hour of 8am, 12pm, 4pm, 8pm, 12 am, and 4am from 16,245 hospitalized patients were analyzed using descriptive statistics and t-tests. Results Although we found a diurnal pattern when analyzing the ensemble of temperatures from all patients (Figure 1), stratified by measurement site (oral, axillary, temporal, and tympanic), the through-to-peak difference was only 0.2F (0.1C), while previously reported diurnal difference in healthy volunteers was 1.9 °F (1.06 °C). Data from the core body temperature sites monotherm and rectal did not show any diurnal pattern. The peaks in body temperature occurred at 8 pm for all patients, regardless of age, which is similar to healthy people. However, the minimum body temperature was shifted to later times compared with healthy people (6am or 2 hours before rising in health) – for young patients (age 20-30 years, N=1285) the through was at 8am and for elderly patients (age 70-80 years, N=1736), it was at 12pm (Figure 2). Analysis of body temperature of individual patients showed that less than 20% of patients exhibited diurnal variation and among those showing variation, the trend was present only on the minority of hospitalization days (Table 1). Interestingly, the presence or absence of an infectious process did not influence the proportion of patients showing diurnal variation. Figure 1 Figure 2 Table 1 Conclusion Hospitalization is associated with disruption in the circadian rhythm as reflected by patients’ body temperature, with shifting of the diurnal variation curve and blunting of the temperature range both in the ensemble and on the individual level. The trend is not influenced by having an infection. However, since core body temperatures tend to be the measurement site of choice in the ICU setting, we suspect that further obliteration of the diurnal rhythm occurs with more severe disease. Disclosures All Authors: No reported disclosures


Sign in / Sign up

Export Citation Format

Share Document