scholarly journals SMILE Platform: An Innovative Microfluidic Approach for On-Chip Sample Manipulation and Analysis in Oral Cancer Diagnosis

Micromachines ◽  
2021 ◽  
Vol 12 (8) ◽  
pp. 885
Author(s):  
Sofia Zoupanou ◽  
Annalisa Volpe ◽  
Elisabetta Primiceri ◽  
Caterina Gaudiuso ◽  
Antonio Ancona ◽  
...  

Oral cancer belongs to the group of head and neck cancers, and, despite its large diffusion, it suffers from low consideration in terms of prevention and early diagnosis. The main objective of the SMILE platform is the development of a low-cost device for oral cancer early screening with features of high sensitivity, specificity, and ease of use, with the aim of reaching a large audience of possible users and realizing real prevention of the disease. To achieve this goal, we realized two microfluidic devices exploiting low-cost materials and processes. They can be used in combination or alone to obtain on-chip sample preparation and/or detection of circulating tumor cells, selected as biomarkers of oral cancer. The realized devices are completely transparent with plug-and-play features, obtained thanks to a highly customized architecture which enables users to easily use them, with potential for a common use among physicians or dentists with minimal training.

Sensors ◽  
2018 ◽  
Vol 18 (9) ◽  
pp. 3035 ◽  
Author(s):  
Laurentiu Susu ◽  
Andreea Campu ◽  
Ana Craciun ◽  
Adriana Vulpoi ◽  
Simion Astilean ◽  
...  

Paper-based platforms can be a promising choice as portable sensors due to their low-cost and facile fabrication, ease of use, high sensitivity, specificity and flexibility. By combining the qualities of these 3D platforms with the optical properties of gold nanoparticles, it is possible to create efficient nanodevices with desired biosensing functionalities. In this work, we propose a new plasmonic paper-based dual localized surface plasmon resonance–surface-enhanced Raman scattering (LSPR-SERS) nanoplatform with improved detection abilities in terms of high sensitivity, uniformity and reproducibility. Specifically, colloidal gold nanorods (GNRs) with a well-controlled plasmonic response were firstly synthesized and validated as efficient dual LSPR-SERS nanosensors in solution using the p-aminothiophenol (p-ATP) analyte. GNRs were then efficiently immobilized onto the paper via the immersion approach, thus obtaining plasmonic nanoplatforms with a modulated LSPR response. The successful deposition of the nanoparticles onto the cellulose fibers was confirmed by LSPR measurements, which demonstrate the preserved plasmonic response after immobilization, as well as by dark-field microscopy and scanning electron microscopy investigations, which confirm their uniform distribution. Finally, a limit of detection for p-ATP as low as 10−12 M has been achieved by our developed SERS-based paper nanoplatform, proving that our optimized plasmonic paper-based biosensing design could be further considered as an excellent candidate for miniaturized biomedical applications.


Lab on a Chip ◽  
2018 ◽  
Vol 18 (3) ◽  
pp. 532-539 ◽  
Author(s):  
Dongyue Jiang ◽  
Seunguk Lee ◽  
Sung Woo Bae ◽  
Sung-Yong Park

We present a smartphone integrated optoelectrowetting (SiOEW) device as a low-cost, portable tool for on-chip sample preparation and microscopic detection of water quality.


2013 ◽  
Vol 2013 (DPC) ◽  
pp. 001486-001519
Author(s):  
Curtis Zwenger ◽  
JinYoung Khim ◽  
YoonJoo Khim ◽  
SeWoong Cha ◽  
SeungJae Lee ◽  
...  

The tremendous growth in the mobile handset, tablet, and networking markets has been fueled by consumer demand for increased mobility, functionality, and ease of use. This, in turn, has been driving an increase in functional convergence and 3D integration of IC devices, resulting in the need for more complex and sophisticated packaging techniques. A variety of advanced IC interconnect technologies are addressing this growing need, such as Thru Silicon Via (TSV), Chip-on Chip (CoC), and Package-on-Package (PoP). In particular, the emerging Wafer Level Fan-Out (WLFO) technology provides unique and innovative extensions into the 3D packaging realm. Wafer Level Fan-Out is a package technology designed to provide increased I/O density within a reduced footprint and profile for low density single & multi-die applications at a lower cost. The improved design capability of WLFO is due, in part, to the fine feature capabilities associated with wafer level packaging. This can allow much more aggressive design rules to be applied compared to competing laminate-based technologies. In addition, the unique characteristics of WLFO enable innovative 3D structures to be created that address the need for IC integration in emerging mobile and networking applications. This paper will review the development of WLFO and its extension into unique 3D structures. In addition, the advantages of these WLFO designs will be reviewed in comparison to current competing packaging technologies. Process & material characterization, design simulation, and reliability data will be presented to show how WLFO is poised to provide robust, reliable, and low cost 3D packaging solutions for advanced mobile and networking products.


2020 ◽  
Author(s):  
Karina Rossi da Silva ◽  
William Ribeiro da Silva ◽  
Bianca Piraccini Silva ◽  
Adriano Nobre Arcos ◽  
Francisco A. da Silva Ferreira ◽  
...  

AbstractThe control of arboviruses carried by Aedes aegypti (Linnaeus) and Aedes albopictus (Skuse) can be performed with tools that monitor and reduce the circulation of these vectors. Therefore, the efficiency of four types of traps in capturing A. aegypti and A. albopictus eggs and adults, with the biological product Vectobac WG®, was evaluated in the field. For this, 20 traps were installed in two locations, which were in the South (Londrina, Paraná) and North (Manaus, Amazonas) Regions of Brazil, from March to April 2017 and January to February 2018, respectively. The UELtrap-E and UELtrap-EA traps captured A. aegypti and A. albopictus eggs: 1703/1866 eggs in Londrina, and 10268/2149 eggs in Manaus, respectively, and presented high ovitraps positivity index (OPI) values (averages: 100%/100% in Londrina, and 100%/96% in Manaus, respectively); and high egg density index (EDI) values (averages: 68/75 in Londrina, and 411/89 in Manaus, respectively), so they had statistically superior efficiency to that of the CRtrap-E and CRtrap-EA traps in both regions, that captured less eggs and adults: 96/69 eggs in Londrina, and 1091/510 eggs in Manaus, respectively. Also presented lower OPI values (averages: 28%/4% in Londrina, and 88%/60% in Manaus, respectively); and lower EDI values (averages: 10.5/9 in Londrina, and 47/30 in Manaus, respectively). The capture ratios of Aedes adults in the UELtrap-EA and CRtrap-EA traps in Londrina and Manaus were 53.3%/29.5% and 0%/9.8%, respectively. UELtrap-E and UELtrap-EA can be adopted as efficient tools for Aedes monitoring due to their high sensitivity, low cost and ease of use.Author summaryAedes aegypti and Aedes albopictus are species of mosquitoes responsible for the transmission of several arboviruses that cause infections worldwide. However, there are still no effective and safe vaccines or medications to prevent or treat arboviruses transmitted by these vectors, except for yellow fever. Moreover, current methodologies for monitoring and controlling A. aegypti and A. albopictus are not fully effective, as evidenced by the increasing cases of the arbovirus transmitted by these mosquitoes or have incompatible costs with the socioeconomic conditions of a large number of people. Thus, the traps tested in this study can be used as more effective and economical tools for monitoring and controlling A. aegypti and A. albopictus, since they are made with low cost material and they showed high efficiency in the capture of eggs, evidenced by the high values of ovitraps positive index and eggs density index, besides that one of the models captured Aedes spp. adults in both regions where they were tested. Therefore, the traps have potential for reducing Aedes spp. eggs and adults in the environment and sensibility for determining the local infestation index, which can be reconciled with official government strategies for more accurate vector monitoring and control actions.


2019 ◽  
Author(s):  
Jing Bai ◽  
Haosi Lin ◽  
Haojian Li ◽  
Yang Zhou ◽  
Junshan Liu ◽  
...  

AbstractThe mortality rate of hemorrhagic African swine fever (ASF), which targets domestic pigs and is caused by African swine fever virus (ASFV), can reach 100%. ASF has been reported in 25 Chinese provinces since August 2018. There is no effective treatment or vaccine for it and the present molecular diagnosis technologies have trade-offs in sensitivity, specificity, cost and speed, and none of them cater perfectly to ASF control. Thus, a technology that overcomes the need for laboratory facilities, is relatively low cost, and rapidly and sensitively detects ASFV would be highly valuable. Here, we describe an RAA-Cas12a-based system that combines recombinase-aided amplification (RAA) and CRISPR/Cas12a for ASFV detection. The fluorescence intensity readout of this system detected ASFV p72 gene levels as low as 10 aM. For on-site ASFV detection, lateral-flow strip readout was introduced for the first time in the RAA-Cas12a based system (named CORDS, Cas12a-based On-site and Rapid Detection System). We used CORDS to detect target DNA highly specifically using the lateral-flow strip readout. CORDS could identify the p72 gene at femtomolar sensitivity in an hour at 37°C, and only requires an incubator. For ease of use, the regents of CORDS was lyophilized to three tubes and remained the same sensitivity when stored at 4 °C for at least 7 days. Thus, CORDS provides a rapid, sensitive and easily operable method for ASFV on-site detection. Lyophilized CORDS can withstand long-term transportation and storage, and is ready for field applications.


Sensors ◽  
2019 ◽  
Vol 19 (10) ◽  
pp. 2373 ◽  
Author(s):  
Imad Abrao Nemeir ◽  
Joseph Saab ◽  
Walid Hleihel ◽  
Abdelhamid Errachid ◽  
Nicole Jafferzic-Renault ◽  
...  

Breast Cancer is one of the world’s most notorious diseases affecting two million women in 2018 worldwide. It is a highly heterogeneous disease, making it difficult to treat. However, its linear progression makes it a candidate for early screening programs, and the earlier its detection the higher the chance of recovery. However, one key hurdle for breast cancer screening is the fact that most screening techniques are expensive, time-consuming, and cumbersome, making them impractical for use in several parts of the world. One current trend in breast cancer detection has pointed to a possible solution, the use of salivary breast cancer biomarkers. Saliva is an attractive medium for diagnosis because it is readily available in large quantities, easy to obtain at low cost, and contains all the biomarkers present in blood, albeit in lower quantities. Affinity sensors are devices that detect molecules through their interactions with biological recognition molecules. Their low cost, high sensitivity, and selectivity, as well as rapid detection time make them an attractive alternative to traditional means of detection. In this review article, we discuss the current status of breast cancer diagnosis, its salivary biomarkers, as well as the current trends in the development of affinity sensors for their detection.


2013 ◽  
Vol 61 (2) ◽  
Author(s):  
Mohamad Faizal Abdullah ◽  
P. L. Leow ◽  
M. A. Abd Razak ◽  
F. K. Che Harun

Significant attention has been given on the development of droplets–based microfluidic system because of its potential and apparent advantages. Beside the advantages of reducing the sample volume, it’s also offer less time consuming for the analysis. Optical and fluorescence among the famous method that was used in detection of droplets but they are normally bulky, expensive and not easily accessed. This paper proposed a simple, low cost and high sensitivity for droplets sensing in microfluidic devices by using capacitive sensor. Coplanar electrodes are used to form a capacitance through the microfluidic channel. The design of eight pair of electrodes was used to detect the presence of a droplet. Changes in capacitance due to the presence of a droplet in the sensing area is detected and used to trigger the microscope to capture the image of detected droplets in microchannel. The measurement of droplets detected and counting are displayed through a LABVIEW interface in the real time.


Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 953
Author(s):  
Catarina R. F. Caneira ◽  
Denis R. Santos ◽  
Virginia Chu ◽  
João P. Conde

Nanoporous microbead-based microfluidic systems for biosensing applications allow enhanced sensitivities, while being low cost and amenable for miniaturization. The regeneration of the microfluidic biosensing system results in a further decrease in costs while the integration of on-chip signal transduction enhances portability. Here, we present a regenerable bead-based microfluidic device, with integrated thin-film photodiodes, for real-time monitoring of molecular recognition between a target DNA and complementary DNA (cDNA). High-sensitivity assay cycles could be performed without significant loss of probe DNA density and activity, demonstrating the potential for reusability, portability and reproducibility of the system.


2018 ◽  
Vol 19 (2) ◽  
pp. 134-153 ◽  
Author(s):  
AHMAD ANWAR ZAINUDDIN ◽  
ANIS NURASHIKIN NORDIN ◽  
ROSMINAZUIN AB RAHIM

ABSTRACT: Dengue illness is an infectious tropical disease, transmitted by Aedes mosquitos, that poses a serious health threat to the tropical world. This disease causes widespread infection worldwide, with about 50 million cases of dengue occurring per annum out of which 500,000 recorded cases of dengue hemorrhagic fever and 22,000 deaths.  Currently, there are no effective vaccines available to prevent the spread of the infection. Accurate and rapid laboratory diagnostic tests are required for early detection to reduce patient mortality rate. In this paper,  common laboratory diagnosis methods for detecting dengue virus infection are discussed. Currently, virus isolation, RT-PCR and serology methods provide the most direct and accurate response for detection of dengue. However, these methods require tedious steps, expensive requirements and expert staffs. Recent research have proposed the usage of biosensors as an alternative new technology for detection of dengue. In this work, various types of biosensors such as electrochemical, piezoelectric, and optical biosensor have been described and compared to evaluate their effectiveness in dengue detection.  It is observed that the optical biosensor offers the best detection due to its high sensitivity as compared to others, although it is popularly known as an expensive method. Alternatively, the use of electrochemical and piezoelectric biosensors (QCM) is highly recommended for detection of dengue due to their ease-of-use, low cost, low reagent consumption, disposability, and minimal sample preparation. These approaches have the potential to improve the rate of survival, particularly in resource-limited countries. ABSTRAK: Virus denggi adalah penyakit berjangkit tropika bawaan nyamuk Aedes yang menimbulkan ancaman serius kepada kesihatan global. Penyakit ini menyebabkan jangkitan yang meluas di seluruh dunia, dengan kira-kira 50 juta kes denggi yang berlaku setiap tahun di mana 500,000 kes demam denggi berdarah dan 22,000 kematian direkodkan. Buat masa ini, tiada vaksin yang berkesan untuk mencegah penyebaran jangkitan ini. Ujian diagnostik makmal yang cepat dan tepat diperlukan untuk pengesanan denggi awal untuk mengurangkan kadar kematian pesakit. Dalam artikel ini, kaedah diagnosis makmal yang biasa dilakukan untuk mengesahkan jangkitan virus denggi akan dibincangkan. Pada masa kini, kaedah pengasingan virus, RT-PCR dan serologi adalah tindak balas yang paling cepat dan tepat untuk mengesan denggi. Walau bagaimanapun, kaedah-kaedah ini memerlukan langkah-langkah yang melecehkan, kos penyelenggaraan yang tinggi dan kakitangan  yang terlatih.  Penyelidikan terkini telah mencadangkan penggunaan biosensor sebagai teknologi baru alternatif untuk mengesan denggi.  Dalam artikel  ini juga pelbagai jenis biosensor seperti biosensor elektrokimia, piezoelektrik, dan biosensor optik telah dijelaskan dan dibandingkan untuk menilai keberkesanannya dalam pengesanan denggi. Difahamkan bahawa biosensor optik menawarkan pengesanan terbaik kerana kepekaannya yang tinggi berbanding dengan yang lain, walaupun ia dikenali sebagai kaedah berkos tinggi. Sebaliknya, biosensor elektrokimia dan piezoelektrik (QCM) sangat disyorkan untuk mengesan denggi kerana ia mudah digunakan, berkos rendah, penggunaan bahan uji yang terhad, boleh dipakai buang, dan mempunyai penyediaan sampel yang minima. Pendekatan-pendekatan ini berpotensi untuk meningkatkan kadar kemandirian di kawasan-kawasan sumber terhad.


Sign in / Sign up

Export Citation Format

Share Document