scholarly journals Mode Conversion Behavior of Guided Wave in a Pipe Inspection System Based on a Long Waveguide

Sensors ◽  
2016 ◽  
Vol 16 (10) ◽  
pp. 1737 ◽  
Author(s):  
Feiran Sun ◽  
Zhenguo Sun ◽  
Qiang Chen ◽  
Riichi Murayama ◽  
Hideo Nishino
Author(s):  
Zongqi Sun ◽  
Li Zhang ◽  
Brian Gavigan ◽  
Takahiro Hayashi ◽  
Joseph L. Rose

The excitation and propagation characteristics of guided wave torsional flexural mode are exploited in this paper. Theoretical computations and experiments are carried out to show the angular profiles of the torsional flexural modes propagation characteristics and the subsequent natural focusing effects. Because of such inherent advantages as less mode conversion and high sensitivity to axial defects, torsional modes and focusing possibilities have great potential in pipe inspection. By combining longitudinal and torsional modes, defect characterizations including defect size, shape etc. can be determined by truly three-dimensional guided wave pipe inspection.


Author(s):  
Shi Yan ◽  
Binbin He ◽  
Naizhi Zhao

Pipeline structure may generate damages during its service life due to the influence of environment or accidental loading. The damages need to be detected and repaired if they are severe enough to influence the transportation work. Non-destructive detection using smart materials combined with suitable diagonal algorithms are widely used in the field of structural health monitoring (SHM). Piezoelectric ceramics (such as Lead Zirconate Titanate, PZT) is one of the smart materials to be applied in the SHM due to the piezoelectric effect. So far, the PZT-based wave method is widely used for damage detection of structures, in particular, pipeline structures. A series of piezoelectric patches are bonded on the surface of the pipeline structure to monitor the damages such as local crack or effective area reduction due to corrosion by using diagonal waves. The damage of the pipeline structure can be detected by analysis of the received diagonal waves which peak value, phase, and arriving time can be deferent from the health ones. The response of the diagonal wave is not only correlated to the damage location through estimation of the arrival time of the wave peak, but also associated with the peak value of the wave for the reduction of wave energy as the guided wave passing through the damages. Therefore, the presence of damages in the pipeline structure can be detected by investigating the parameter change of the guided waves. The change of the wave parameters represents the attenuation, deflection and mode conversion of the waves due to the damages. In addition, the guided wave has the ability of quick detecting the damage of the pipeline structure and the simplicity of generating and receiving detection waves by using PZT patches. To verify the proposed method, an experiment is designed and tested by using a steel pipe bonded the PZT patches on the surface of it. The PZT patches consist of an array to estimate the location and level of the damage which is simulated by an artificial notch on the surface of the structure. The several locations and deep heights of the notches are considered during the test. A pair of the PZT patches are used at the same time as one is used as an actuator and the other as a sensor, respectively. A tone burst of 5 cycles of wave shape is used during the experiment. A wave generator is applied to create the proposed waves, and the waves are amplified by an amplifier to actuate the PZT patch to emit the diagonal waves with appropriately enough energy. Meanwhile, the other PZT patch is used as a sensor to receive the diagonal signals which contain the information of the damages for processing. For data processing, an index of root mean square deviation (RMSD) of the received data is used to estimate the damage level by compare of the data between the damaged and the health peak valves of the received signals. The time reversal method which aimed at increasing the efficiency of the detection is also used to detect the damage location by estimating the arrival time of the reflected wave passing with a certain velocity. The proposed method experimentally validates that it is effective for application in damage detection of pipeline structure.


2019 ◽  
Vol 2019 ◽  
pp. 1-9
Author(s):  
Yao Liu ◽  
Xiucheng Liu ◽  
Chehua Yang ◽  
Wenxin Guo ◽  
Bin Wu ◽  
...  

In the study, ultrasonic longitudinal mode guided waves were employed to detect defects in elbowed tubes (without welds) with a diameter of 10 mm. Finite element simulation results highlighted that the emitted L(0,1) mode guided waves experienced strong reflection and mode conversion at the elbow region to generate F(1,1) mode, followed by slow and weak F(2,1) mode. The guided wave reflected from the elbow with a through-wall defect was manifested as two overlapped wave packets, which were good indicators of a defective elbow. To conduct L(0,1) mode guided waves inspection on the small-diameter elbowed tubes, a novel tailored squirrel-cage magnetostrictive sensor was employed in the experiment. The new sensor employed the configuration of segmental iron-cobalt strips and small-size permanent magnet arrays. The entire sensor is composed of two identical C-shaped sensor elements and can be recycled and installed conveniently. Experimental results obtained from healthy and defective tubes were consistent with the conclusions obtained from finite element simulations. An artificial through-wall defect at the elbow and a notch defect at the straight part of the tube could be simultaneously detected by L(0,1) mode guided waves through comparing experimental signals with simulation results.


Author(s):  
Takahiro Hayashi ◽  
Koichiro Kawashima ◽  
Zongqi Sun ◽  
Joseph L. Rose

Guided waves can be used in pipe inspection over long distances. Presented in this paper is a beam focusing technique to improve the S/N ratio of the reflection from a tiny defect. Focusing is accomplished by using non-axisymmetric waveforms and subsequent time delayed superposition at a specific point in a pipe. A semi-analytical finite element method is used to present wave structure in the pipe. Focusing potential is also studied with various modes and frequencies.


2013 ◽  
Vol 395-396 ◽  
pp. 787-791
Author(s):  
Jing Wu ◽  
Wei Wei Zhang

This paper aims to develop a method to identify the damage location in circumference direction of a pipe using mode transformation of longitudinal guided wave. The corrosion-like damage in bimetal pipe is considered. Case study that damage detection for a bimetal pipe is used to show the validity and advantage of the proposed method. It can be found that the axially symmetric mode guided wave encounter the damage and the three modes were received in reflection. The damage location in circumferential directions could be identified by conversed modes measured at one position. The simulation shows a good performance.


Author(s):  
Scott M. Bland ◽  
Shiv P. Joshi

This paper discusses the development and testing of an automated robotic ultrasonic guided wave based inspection system developed to provide an efficient, accurate and reliable method for performing nondestructive evaluation and longer term structural health monitoring in advanced composite structures. The development process and challenges in the design of the automated robotic system are described. A number of tests were performed using the developed robotic ultrasonic inspection system on composite honeycomb core sandwich materials. Experiments showed that the developed automated ultrasonic guided wave inspection system was successful at locating disbonds between the core and the facesheets. Environmental sensitivity testing was also performed to characterize the effect of changing temperature and humidity on system performance. These tests indicate that approach was relatively insensitive to environmental changes, so that this approach could be used in service environment without a significant reduction in performance. Current system testing indicates that the described robotic ultrasonic inspection approach offers an accurate and robust method for inspection and long term tracking of advanced structural system health.


2021 ◽  
Author(s):  
Christian Peyton ◽  
Rachel S. Edwards ◽  
Steve Dixon ◽  
Ben Dutton ◽  
Wilson Vesga

Abstract This paper investigates the interaction behaviour between the fundamental shear horizontal guided wave mode and small defects, in order to understand and develop an improved inspection system for titanium samples. In this work, an extensive range of defect sizes have been simulated using finite element software. The SH0 reflection from a defect has been shown previously to depend on its length as the total reflection consists of reflections from both the front and back face. However, for small defect widths, this work has found that the width also affects this interference, changing the length at which the reflection is largest. In addition, the paper looks at how the size of the defect affects the mode converted S0 reflection and SH0 diffraction. The relationship between the SH0 diffraction and defect size is shown to be more complex compared to the reflections. The mode converted S0 reflection occurs at an angle to the incident wave direction; therefore, the most suitable angle for the detection has been found. Simultaneous measurement of multiple waves would bring benefits to inspection.


Author(s):  
Zhaoyun Ma ◽  
Lingyu Yu ◽  
Poh-Sang Lam ◽  
Robert L. Sindelar ◽  
Andrew J. Duncan ◽  
...  

Abstract Stress corrosion cracking (SCC) has been observed in the high-level nuclear waste tanks that were constructed by welding carbon steel plates. This paper aims to establish an ultrasonic inspection system and its fundamental ability for SCC inspection and quantification on thick welded steel plates. A welded steel plate was fabricated without heat treatment by joining two carbon steel plates through gas metal arc welding (GMAW) procedure. SCC growth, which was initiated with starter cracks across the weld, were observed in a few weeks after submerging the plate in 5 molar (5M) sodium nitrate (NaNO3) solution at about 90 °C. The SCC is inspected with an ultrasonic guided wave system, which employs a piezoelectric transducer for guided wave actuation and a scanning laser Doppler vibrometer (SLDV) for wavefield sensing. The measured wavefield can immediately show wave interactions with the crack. Wavefield images are further generated for the crack length quantification. To demonstrate the crack sizing capability of using the piezoelectric transducer and SLDV, the previous results from the magnetic particle test (MT) are compared. Reasonable agreement in crack length measurement is obtained with the ultrasonic test imaging technique.