scholarly journals Reliability and Validity of the SHFT Running Power Meter

Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7516
Author(s):  
Jesper Emil Linkis ◽  
Thomas Christian Bonne ◽  
Jacob Bejder ◽  
Esben Krogh Rasmussen ◽  
Andreas Breenfeldt Andersen ◽  
...  

The SHFT device is a novel running wearable consisting of two pods connected to your smartphone issuing several running metrics based on accelerometer and gyroscope technology. The purpose of this study was to investigate the reliability and validity of the power output (PO) metric produced by the SHFT device. To assess reliability, 12 men ran on an outdoor track at 10.5 km·h−1 and 12 km·h−1 on two consecutive days. To assess validity, oxygen uptake (VO2) and SHFT data from eight men and seven women were collected during incremental submaximal running tests on an indoor treadmill on one to four separate days (34 tests in total). SHFT reliability on the outdoor track was strong with coefficients of variance (CV) of 1.8% and 2.4% for 10.5 and 12 km·h−1, respectively. We observed a very strong linear relationship between PO and VO2 (r2 = 0.54) within subjects, and a very strong linear relationship within each subject within each treadmill test (r2 = 0.80). We conclude that SHFT provides a reliable running power estimate and that a very strong relationship between SHFT-Power and metabolic rate exists, which places SHFT as one of the leading commercially available running power meters.

2021 ◽  
Author(s):  
Stephen M Kareha ◽  
Philip W McClure ◽  
Alicia Fernandez-Fernandez

Abstract Objective Rating tissue irritability has been recommended to aid decision making in several recent clinical practice guidelines. An explicit method for rating tissue irritability was proposed as part of the Staged Algorithm for Rehabilitation Classification: Shoulder Disorders (STAR-Shoulder), but the reliability and validity of this classification are unknown. The purpose of this study was to examine the reliability and concurrent validity of shoulder tissue irritability ratings as part of a system designed to guide appropriate treatment strategy and intensity. Methods A clinical measurement, prospective repeated-measures cross-sectional design was used. The 101 consecutive participants with primary complaints of shoulder pain were assessed by pairs of blinded raters (24 raters in total) and rated for tissue irritability. Patients completed 3 patient-rated outcome (PRO) measures reflecting both pain and disability, and these scores were compared with ratings of tissue irritability. Paired ratings of irritability were analyzed for reliability with prevalence-adjusted, bias-adjusted Kappa for ordinal scales (PABAK-OS). Analysis of variance (ANOVA) was used to compare PRO measures across different levels of irritability. Receiver operating characteristic (ROC) curve analysis was utilized to derive cut-off scores for 3 PRO instruments. Results Interrater reliability was 0.69 (95% CI = 0.59–0.78), with 67% agreement. All PRO measures were significantly different among 3 levels of tissue irritability. Conclusion There appear to be acceptable reliability and a strong relationship between PRO measures and therapist-rated tissue irritability, supporting the use of the STAR-Shoulder irritability rating system. Impact Several clinical practice guidelines have recommended that clinicians rate tissue irritability as part of their examination. This study provides important new information supporting the reliability and validity of the STAR-Shoulder tissue irritability rating system.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2789
Author(s):  
Víctor Rodríguez-Rielves ◽  
José Ramón Lillo-Beviá ◽  
Ángel Buendía-Romero ◽  
Alejandro Martínez-Cava ◽  
Alejandro Hernández-Belmonte ◽  
...  

This study aimed to examine the validity and reliability of the recently developed Assioma Favero pedals under laboratory cycling conditions. In total, 12 well-trained male cyclists and triathletes (VO2max = 65.7 ± 8.7 mL·kg−1·min−1) completed five cycling tests including graded exercises tests (GXT) at different cadences (70–100 revolutions per minute, rpm), workloads (100–650 Watts, W), pedaling positions (seated and standing), vibration stress (20–40 Hz), and an 8-s maximal sprint. Tests were completed using a calibrated direct drive indoor trainer for the standing, seated, and vibration GXTs, and a friction belt cycle ergometer for the high-workload step protocol. Power output (PO) and cadence were collected from three different brand, new pedal units against the gold-standard SRM crankset. The three units of the Assioma Favero exhibited very high within-test reliability and an extremely high agreement between 100 and 250 W, compared to the gold standard (Standard Error of Measurement, SEM from 2.3–6.4 W). Greater PO produced a significant underestimating trend (p < 0.05, Effect size, ES ≥ 0.22), with pedals showing systematically lower PO than SRM (1–3%) but producing low bias for all GXT tests and conditions (1.5–7.4 W). Furthermore, vibrations ≥ 30 Hz significantly increased the differences up to 4% (p < 0.05, ES ≥ 0.24), whereas peak and mean PO differed importantly between devices during the sprints (p < 0.03, ES ≥ 0.39). These results demonstrate that the Assioma Favero power meter pedals provide trustworthy PO readings from 100 to 650 W, in either seated or standing positions, with vibrations between 20 and 40 Hz at cadences of 70, 85, and 100 rpm, or even at a free chosen cadence.


2011 ◽  
Vol 91 (2) ◽  
pp. 425-428 ◽  
Author(s):  
Christian Willenborg ◽  
Lloyd Dosdall

Willenborg, C. J. and Dosdall, L. M. 2011. First report of redbacked cutworm damage to cow cockle [ Vaccaria hispanica(Mill.) Rauschert], a potential new crop for western Canada. Can. J. Plant Sci. 91: 425–428. We report the effects of redbacked cutworm Euxoa ochrogaster (Guenée) on cow cockle [Vaccaria hispanica (Mill.) Rauschert] plant height, seed yield, and 1000-seed weight (TSW). Euxoa ochrogaster damage to plots varied considerably among genotypes, with some genotypes exhibiting <10% damage and others >45%. Seed yield also varied significantly among genotypes and exhibited a strong linear relationship with the extent of E. ochrogaster damage. This is the first known report of any insect pest feeding on cow cockle. Results suggest that E. ochrogaster has the potential to cause significant losses in cow cockle crops.


1953 ◽  
Vol 9 (4) ◽  
pp. 379-390 ◽  
Author(s):  
M. REISS ◽  
EVA BRUMMEL ◽  
I. D. K. HALKERSTON ◽  
F. E. BADRICK ◽  
M. FENWICK

A technique for measuring the action of small doses of ACTH on the oxygen consumption of slices of cattle adrenal cortex is described. The oxygen consumption rate of such slices in vitro is increased by ACTH. A linear relationship between logarithm of the dose of ACTH and the percentage increase in the rate of oxygen uptake is obtained with this method, and its suitability for biological assay purposes has been investigated. The question of the specificity of this action of ACTH is discussed.


2019 ◽  
Vol 14 (10) ◽  
pp. 1382-1387 ◽  
Author(s):  
Paul F.J. Merkes ◽  
Paolo Menaspà ◽  
Chris R. Abbiss

Purpose: To determine the validity of the Velocomp PowerPod power meter in comparison with the Verve Cycling InfoCrank power meter. Methods: This research involved 2 separate studies. In study 1, 12 recreational male road cyclists completed 7 maximal cycling efforts of a known duration (2 times 5 s and 15, 30, 60, 240, and 600 s). In study 2, 4 elite male road cyclists completed 13 outdoor cycling sessions. In both studies, power output of cyclists was continuously measured using both the PowerPod and InfoCrank power meters. Maximal mean power output was calculated for durations of 1, 5, 15, 30, 60, 240, and 600 seconds plus the average power output in study 2. Results: Power output determined by the PowerPod was almost perfectly correlated with the InfoCrank (r > .996; P < .001) in both studies. Using a rolling resistance previously reported, power output was similar between power meters in study 1 (P = .989), but not in study 2 (P = .045). Rolling resistance estimated by the PowerPod was higher than what has been previously reported; this might have occurred because of errors in the subjective device setup. This overestimation of rolling resistance increased the power output readings. Conclusion: Accuracy of rolling resistance seems to be very important in determining power output using the PowerPod. When using a rolling resistance based on previous literature, the PowerPod showed high validity when compared with the InfoCrank in a controlled field test (study 1) but less so in a dynamic environment (study 2).


2016 ◽  
Vol 11 (1) ◽  
pp. 68
Author(s):  
Laura Costello

A Review of: Lamothe, A. R. (2015). Comparing usage between dynamic and static e-reference collections. Collection Building, 34(3), 78-88. http://dx.doi.org/10.1108/CB-04-2015-0006 Abstract Objective – To discover whether there is a difference in use over time between dynamically updated and changing subscription e-reference titles and collections, and static purchased e-reference titles and collections. Design – Case study. Setting – A multi-campus Canadian university with 9,200 students enrolled in both graduate and undergraduate programs. Subjects – E-reference book packages and individual e-reference titles. Methods – The author compared data from individual e-reference books and packages. First, individual subscription e-reference books that periodically added updated content were compared to individually purchased e-reference books that remained static after purchase. The author then compared two e-reference book packages that provided new and updated content to two static e-reference book packages. The author compared data from patron usage to new content added over time using regression analysis. Main Results – As the library acquired e-reference titles, dynamic title subscriptions added to the collection were associated with 2,246 to 4,635 views per subscription while static title additions were associated with 8 to 123 views per purchase. The author also found that there was a strong linear relationship between views and dynamic titles added to the collection (R2=0.79) and a very weak linear relationship (R2=0.18) with views when static titles are added to the collection. Regression analysis of dynamic e-reference collections revealed that the number of titles added to each collection was strongly associated with views of the material (R2=0.99), while static e-reference collections were less strongly linked (R2=0.43). Conclusion – Dynamic e-reference titles and collections experienced increases in usage each year while static titles and collections experienced decreases in usage. This indicates that collections and titles that offer new content to users each year will continue to see growth in usage while static collections and titles will see maximum usage within a few years and then begin to decline as they get older. Fresh content is strongly associated with usage in e-reference titles, which mirrors the author’s previous work examining static and dynamic content in e-monographs.


2013 ◽  
Vol 10 (2) ◽  
pp. 271-279 ◽  
Author(s):  
Renee E. Magnan ◽  
Bethany M. Kwan ◽  
Joseph T. Ciccolo ◽  
Burke Gurney ◽  
Christine M. Mermier ◽  
...  

Background:Maximal oxygen uptake (VO2max), an assessment of cardiorespiratory fitness, is regularly used as the primary outcome in exercise interventions. Many criteria have been suggested for validating such tests—most commonly, a plateau in oxygen consumption. The current study investigated the proportion of inactive individuals who reached a plateau in oxygen uptake and who achieved a valid test as assessed by secondary criteria (RERmax ≥ 1.1; RPEmax ≥ 18; age predicted HRmax ±10bpm), and the correlates of a successful plateau or achievement of secondary criteria during a VO2max session.Methods:Participants (n = 240) were inactive individuals who completed VO2max assessments using an incremental treadmill test. We explored physical, behavioral, and motivational factors as predictors of meeting criteria for meeting a valid test.Results:Approximately 59% of the sample achieved plateau using absolute (increase of VO2 of 150ml O2 or less) and 37% achieved plateau using relative (increase of VO2 of 1.5ml/kg O2 or less) criteria. Being male, having a higher BMI, a greater waist-to-hip ratio, and increased self-efficacy were associated with lower odds of achieving an absolute plateau, whereas none of these factors predicted odds of achieving relative plateau.Conclusion:Findings raise questions about the validity of commonly used criteria with less active populations.


1991 ◽  
Vol 3 (2) ◽  
pp. 111-120 ◽  
Author(s):  
Joanne R. Williams ◽  
Neil Armstrong

A total of 100 boys and 91 girls, ages 11 to 16 years, completed a discontinuous treadmill test to voluntary exhaustion to determine the oxygen uptake/blood lactate relationship. Maturational stage was assessed in 72 boys and 47 girls using Tanner’s indices. Mean blood lactate at peak VO2 was significantly higher in the girls compared to the boys (6.1 vs. 5.8 mmol•l-1, P<0.01). Lactate at peak VO2 and percent peak VO2 at 4.0 mmol•l-1 were not significantly correlated with chronological age (p>0.05) in either sex, although a relationship was obtained between chronological age and percent peak VO2 at 2.5 mmol•l-“1 for boys (r= ‒0.226, p<.05) and girls (r= ‒0.272, p0.05). Analysis of variance revealed no significant changes (p>0.05) in any of the lactate variables examined with progression through the Tanner stages of maturity.


2006 ◽  
Vol 86 (8) ◽  
pp. 1107-1117 ◽  
Author(s):  
Olaf Verschuren ◽  
Tim Takken ◽  
Marjolijn Ketelaar ◽  
Jan Willem Gorter ◽  
Paul JM Helders

Abstract Background and Purpose. The purpose of this study was to examine the reliability and validity of data obtained with 2 newly developed shuttle run tests (SRT-I and SRT-II) to measure aerobic power in children with cerebral palsy (CP) who were classified at level I or II on the Gross Motor Function Classification System (GMFCS). The SRT-I was developed for children at GMFCS level I, and the SRT-II was developed for children at GMFCS level II. Subjects. Twenty-five children and adolescents with CP (10 female, 15 male; mean age=11.9 years, SD=2.9), classified at GMFCS level I (n=14) or level II (n=11), participated in the study. Methods. To assess test-retest reliability of data for the 10-m shuttle run tests, the subjects performed the same test within 2 weeks. To examine validity, the shuttle run tests were compared with a GMFCS level–based treadmill test designed to measure peak oxygen uptake. Results. Statistical analyses revealed test-retest reliability for exercise time (number of levels completed) (intraclass correlation coefficients of .97 for the SRT-I and .99 for the SRT-II) and reliability for peak heart rate attained during the final level (intraclass correlation coefficients of .87 for the SRT-I and .94 for the SRT-II). High correlations were found for the relationship between data for both shuttle run tests and data for the treadmill test (r=.96 for both). Discussion and Conclusion. The results suggest that both 10-m shuttle run tests yield reliable and valid data. Moreover, the shuttle run tests have advantages over a treadmill test for children with CP who are able to walk and run (GMFCS level I or II). [Verschuren O, Takken T, Ketelaar M, et al. Reliability and validity of data for 2 newly developed shuttle run tests in children with cerebral palsy. Phys Ther. 2006;86:1107–1117.]


Sign in / Sign up

Export Citation Format

Share Document