scholarly journals Effect of Shape of Magnet on the Machining of Workpiece

2019 ◽  
Vol 8 (2S11) ◽  
pp. 2909-2913 ◽  

Viscoelastic Magnetic Abrasive finishing has achieved a wide popularity in the field of finishing as the process is capable of finishing Non-ferrous material along with the ferrous material. With the development in technology the quality and surface finish attract more attention as compare to the machining perfection and dimensional accuracy. The present paper consists of comparison of four type of magnet available in the market and one of them as self-proposed electromagnet. A single aluminium hollow cylindrical workpiece of outer diameter as 10 mm and the inner diameter as 8 mm is finished by taking the magnet one by one whose dimensions are made according to the available literature and market and are placed as two magnetic poles with 180 degrees apparats. Ansys Maxwell 16 software was used to predict the value of maximum magnetic field on the workpiece due to the shape of the magnet and it was found that the maximum magnetic field was produced by fan shape magnet of about 0.6 Tesla. From the idea of magnetic field intensity of the workpiece, the machining ability of the magnet in viscoelastic magnetic field can be produced.

Diagnostics ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1145
Author(s):  
Magdalena Kal ◽  
Izabela Chojnowska-Ćwiąkała ◽  
Mateusz Winiarczyk ◽  
Monika Jasielska ◽  
Jerzy Mackiewicz

Background: The aim of this study was to evaluate the quantitative morphological changes in lamellar macular holes (LMHs) based on SD-OCT examinations and to assess the correlations among minimal retinal thickness (MRT), reading vision (RV), and best corrected visual acuity (BCVA) over a 36-month follow-up period. Methods: A group of 40 patients (44 eyes) with LMH was evaluated, with an average age of 69.87 (SD = 10.14). The quantitative parameters monitored in the follow-up period (at 0, 3, 6, 12, 18, 24, 30, and 36 months) were tested for normality of distribution by Shapiro–Wilk and Kolmogorov–Smirnov tests. Results: The RV and BCVA values were stable, and no significant changes were found at any of the check-ups during the 36-month follow-up period (BCVA p = 0.435 and RV p = 0.0999). The analysis of individual quantitative LMH parameters during the 36-month follow-up period did not demonstrate statistically significant differences: MRT (p = 0.461), Max RT temporal (p = 0.051), Max RT nasal (p = 0.364), inner diameter (ID) (p = 0.089), and outer diameter (OD) (p = 0.985). Conclusions: The observations at 0, 6, 12, 18, 24, 30, and 36 months revealed moderate and significant correlations between RV and MRT. No significant correlation between BCVA and MRT was observed.


Author(s):  
Ajay Kumar Kaviti ◽  
Akkala Siva Ram ◽  
Amit Kumar Thakur

In this experimental study, permanent magnets with three different sizes (M-1: 32 mm inner diameter, 70 mm outer diameter and 15 mm thick, M-2: 25 mm inner diameter, 60 mm outer diameter and 10 mm thick, M-3: 22 mm inner diameter, 45 mm outer diameter and 9 mm thick) are fully submerged in the single-slope glass solar still. The performance of magnetic solar stills (MSS) with three different sizes at 2 cm depth water to ensure that magnets are fully submerged is compared with conventional solar still (CSS) at the location 17.3850°N, 78.4867°E. Tiwari model is adapted to calculate the heat transfer coefficients (HTC), internal and exergy efficiencies. MSS with M-1, M-2 and M-3 significantly enhanced the convective, radiative, and evaporative heat transfer rate for the 2 cm depth of water. This is due to the desired magnetic treatment of water, which reduces the surface tension and increases the hydrogen bonds. The MSS's total internal HTC, instantaneous efficiencies led CSS by 25.52%, 28.8%, respectively, with M-1. Having various magnetic fields due to different magnets sizes increases MSS's exergetic efficiency by 33.61% with M-1, 33.76% with M-2, and 42.25% with M-3. Cumulative yield output for MSS with M-1, M-2, and M-3 is 21.66%, 17.64%, 15.78% higher than CSS. The use of permanent magnets of different sizes in the MSS is a viable, economical and straight forward technique to enhance productivity.


2017 ◽  
Vol 76 (8) ◽  
pp. 1981-1991 ◽  
Author(s):  
Lili Jiang ◽  
Xiayan Yao ◽  
Haitao Yu ◽  
Xingang Hou ◽  
Zongshu Zou ◽  
...  

Effect of a permanent magnet field on the scale inhibition property of circulating water was investigated. Orthogonal experiments of L16(45) were performed and analyzed using the range analysis method. The operating parameters included magnetic field intensity, initial concentration of Ca2+ and Mg2+, magnetic treatment time, temperature, and flow velocity. Scale inhibition rate, hardness, relative variation in the proportion of free water molecules, electrical conductivity, and relative variation of molecular energy were chosen as the objectives. In addition, the morphology and the composition of CaCO3 and MgCO3 scale were studied by X-ray diffraction analysis. The optimal conditions were initial concentration of 900 mg/L, magnetic field intensity of 0.5 T, temperature of 303 K, time of 54 h and flow velocity of 0.17 m/s. The nuclear magnetic resonance results demonstrated that the number of hydrogen bonds increased between water molecules and hydrated ions. The magnetic field can promote the increase in the number of hydrogen bonds, which can inhibit the formation of calcium and magnesium carbonate precipitation. Moreover, the ratio of calcite, aragonite and vaterite will be changed at different magnetic field intensities, and the aragonite ratio will reach the peak at the optimum conditions.


1995 ◽  
Vol 4 (6) ◽  
pp. 597-608 ◽  
Author(s):  
Jiro Hirai ◽  
Takehisa Matsuda

A tubular, hierarchically structured hybrid vascular tissue composed of vascular cells and collagen was prepared. First, a cold mixed solution of bovine aortic smooth muscle cells (SMCs) and Type I collagen was poured into a tubular glass mold composed of a mandrel and a sheath (example of dimensions: inner diameter, 1.5 mm; outer diameter, 7 mm; length, 7 cm). Upon incubation at 37°C, an SMC-incorporated collagenous gel was formed. After the sheath was removed, the resulting fragile tissue, when cultured in medium, thinned in a time-dependent manner to form an opaque, dense tissue. Higher SMC seeding density and lower initial collagen concentration induced more rapid and prominent shrinkage of the tissue. Morphologic investigation showed that over time, bipolarly elongated SMCs and collagen fiber bundles became positioned around the mandrel. Both components became circumferentially oriented. When the mandrel was removed, a tubular hybrid medial tissue was formed. A hybrid vascular tissue with a hierarchical structure was constructed by seeding endothelial cells onto the inner surface of the hybrid medial tissue. Prepared tissues tolerated luminal pressures as great as 100 mmHg and mechanical stress applied during an anastomotic procedure. This method allowed us to prepare a tubular hybrid medial tissue of predetermined size (inner diameter, wail thickness, and length) by selecting appropriate mold design, initial collagen concentration, and SMC seeding density. Such hybrid vascular tissues may provide physiological functions when implanted into the venous system.


2012 ◽  
Vol 1 (2) ◽  
pp. 85-101 ◽  
Author(s):  
E. Kozlovskaya ◽  
A. Kozlovsky

Abstract. Seismic broadband sensors with electromagnetic feedback are sensitive to variations of surrounding magnetic field, including variations of geomagnetic field. Usually, the influence of the geomagnetic field on recordings of such seismometers is ignored. It might be justified for seismic observations at middle and low latitudes. The problem is of high importance, however, for observations in Polar Regions (above 60° geomagnetic latitude), where magnitudes of natural magnetic disturbances may be two or even three orders larger. In our study we investigate the effect of ultra-low frequency (ULF) magnetic disturbances, known as geomagnetic pulsations, on the STS-2 seismic broadband sensors. The pulsations have their sources and, respectively, maximal amplitudes in the region of the auroral ovals, which surround the magnetic poles in both hemispheres at geomagnetic latitude (GMLAT) between 60° and 80°. To investigate sensitivity of the STS-2 seismometer to geomagnetic pulsations, we compared the recordings of permanent seismic stations in northern Finland to the data of the magnetometers of the IMAGE network located in the same area. Our results show that temporary variations of magnetic field with periods of 40–150 s corresponding to regular Pc4 and irregular Pi2 pulsations are seen very well in recordings of the STS-2 seismometers. Therefore, these pulsations may create a serious problem for interpretation of seismic observations in the vicinity of the auroral oval. Moreover, the shape of Pi2 magnetic disturbances and their periods resemble the waveforms of glacial seismic events reported originally by Ekström (2003). The problem may be treated, however, if combined analysis of recordings of co-located seismic and magnetic instruments is used.


2019 ◽  
Vol 97 (3) ◽  
pp. 163-168 ◽  
Author(s):  
Priyanka Sharma ◽  
Srinivasu V. Vallabhapurapu ◽  
Wei H. Ho ◽  
Nanjundaswamy M. Hemmaragala

The novel reactor has been designed to perform chemical reactions under the influence of a magnetic field generated by alternating magnetic poles as a function of time. The system was successfully employed to synthesize a series of 1,5-disubstituted-1,2,3-triazolines via the regioselective [3 + 2] cycloaddition reactions between alkyl/aryl azides and nitroolefins catalysed by Zepto (para magnetic ultra-blue carboxy functionalized) microspheres (bead diameter 2.5 μm). All of the reactions went smoothly without any adverse effect on nitro, cyano, thienyl, hydroxy, halogens, and ether functions at 25 ± 2 °C and afforded 82%–99% pure products at a magnetic field of 18.99 mT and an exposure time of 180–240 min. The influence of the magnetic force exerted on the magnetic materials was found to enhance the catalytic activity of microspheres. The catalyst could easily be separated by simple centrifugation, which could be reused for at least 15 runs with no loss in activity.


2014 ◽  
Vol 23 (01n02) ◽  
pp. 1450008
Author(s):  
Isaac Macwan ◽  
Zihe Zhao ◽  
Omar Sobh ◽  
Jinnque Rho ◽  
Ausif Mahmood ◽  
...  

Magnetotactic bacteria (MTB), discovered in early 1970s contain single-domain crystals of magnetite ( Fe 3 O 4) called magnetosomes that tend to form a chain like structure from the proximal to the distal pole along the long axis of the cell. The ability of these bacteria to sense the magnetic field for displacement, also called magnetotaxis, arises from the magnetic dipole moment of this chain of magnetosomes. In aquatic habitats, these organisms sense the geomagnetic field and traverse the oxic-anoxic interface for optimal oxygen concentration along the field lines. Here we report an elegant use of MTB where magnetotaxis of Magnetospirillum magneticum (classified as AMB-1) could be utilized for controlled navigation over a semiconductor substrate for selective deposition. We examined 50mm long coils made out of 18AWG and 20AWG copper conductors having diameters of 5mm, 10mm and 20mm for magnetic field intensity and heat generation. Based on the COMSOL simulations and experimental data, it is recognized that a compound semiconductor manufacturing technology involving bacterial carriers and carbon-based materials such as graphene and carbon nanotubes would be a desirable choice in the future.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Riham S. H. M. Allam ◽  
Rania A. Ahmed

Purpose. To study features of the lower punctum in normal subjects using spectral domain anterior segment optical coherence tomography (SD AS-OCT).Methods. Observational cross-sectional study that included 147 punctae (76 subjects). Punctae were evaluated clinically for appearance, position, and size. AS-OCT was used to evaluate the punctal shape, contents, and junction with the vertical canaliculus. Inner and outer diameters as well as depth were measured.Results. 24 males and 52 females (mean age44±14.35 y) were included. Lower punctum was perceived by OCT to be an area with an outer diameter (mean412.16±163 μm), inner diameter (mean233.67±138.73 μm), and depth (mean251.7±126.58 μm). The OCT measured outer punctum diameter was significantly less than that measured clinically (P: 0.000). Seven major shapes were identified. The junction with the vertical canaliculus was detectable in 44%. Fluid was detected in 34%, one of which had an air bubble; however, 63% of punctae showed no contents and 4% had debris.Conclusions. AS-OCT can be a useful tool in understanding the anatomy of the punctum and distal lacrimal system as well as tear drainage physiology. Measuring the punctum size may play a role in plugs fitting.


Soft Matter ◽  
2015 ◽  
Vol 11 (18) ◽  
pp. 3512-3529 ◽  
Author(s):  
Juntao Tang ◽  
Patrick James Quinlan ◽  
Kam Chiu Tam

Pickering emulsions with stimuli-responsive properties have, in recent years, received a considerable amount of attention. This paper provides a concise and comprehensive review of Pickering emulsion systems that possess the ability to respond to an array of external triggers, including pH, temperature, CO2concentration, light intensity, ionic strength, and magnetic field intensity.


Sign in / Sign up

Export Citation Format

Share Document