Heart rate responses of two breeds of four-gaited horses to a standardised field gaited test

2012 ◽  
Vol 8 (1) ◽  
pp. 41-46 ◽  
Author(s):  
H.C. Manso Filho ◽  
H.E.C.C.C. Manso ◽  
K.H. McKeever ◽  
S.R.R. Duarte ◽  
J.M.G. Abreu

In order to understand how gaited horses use their energy during exercise, a standardised field gaited test (SFGT) was developed to assess energy expenditure of four beat gaited horses independently of size, sex or breed. This work aimed at developing such an SFGT, using as main measurement parameter the heart rate (HR) of horses during the SFGT performance. Thirty-one four beat gaited horses were evaluated and divided into two groups: FIT (conditioned) and UNFIT (not conditioned). Horses were submitted to the SFGT and their heart rates were measured with a heart rate monitor as follows: right after being mounted, at the beginning of pre-test (HRSADDLE); at 5, 10, 15, 20, 25 and 30 minutes of four beat gait dislocation; and at 15 minutes after the recovery period (T+15). Maximum HR (HRMAX); HR percentage over 150 beats per minute (HR%≯150), HR percentage over 170 beats per minute (HR%≯170), and average HR during the four beat gait stage (HRM@M) of SFGT were calculated. Results were analysed by ANOVA for repeated measures. Where significant differences were observed, ‘T’ test was performed and significance was set at 5%. The FIT group presented HRMAX, HR+15, HRM@M, HR%≯150 and HR%≯170 rates lower (P<0.05) than the UNFIT group. It was noted that there was a negative correlation between fitness and HRMAX (R=−0.67; P<0.001) and a positive correlation between HRMAX and HR+15 (R=0.60; P<0.001) when comparing the FIT to the UNFIT horses. In conclusion, during the SFGT, the FIT group was more efficient in energy expenditure than the UNFIT group, based on the results observed for the significantly lower HRs during the SFGT. It is relevant to note that the SFGT developed and used in this research, which was easily reproduced and accurate, was able to detect and confirm important adaptations related to fitness in the athletic horse.

2021 ◽  
Vol 38 (5) ◽  
pp. 343-349
Author(s):  
Ananda S. Cardoso ◽  
Guilherme P. Berriel ◽  
Pedro Schons ◽  
Rochelle R. Costa ◽  
Luiz Fernando M. Kruel

The aim of this research was to evaluate the behavior of vertical jumps performance in professional volleyball athletes during matches and training and their relationships with fatigue and recovery through heart rate variability (HRV), ratings of perceived exertion (RPE) and perceived recovery status (PRS). Nine male professional volleyball athletes participated in the study, with mean age: 25.66 ± 5.7 years, mean body mass: 97.81 ± 8.65 Kg and mean height: 200.94 ± 5.19 cm, with experience in national and international competitions. HRV and PRS were evaluated in the morning of matches and in the presentation for the first day of training after matches. RPE was collected immediately after matches and at the end of training days. Jumps performance was monitored during the matches and during the first days of training. The data was grouped by matches and training sessions. Significance level adopted was α ≤ 0.05. There were no alterations in HRV and PRS evaluated after matches and before training sessions, as well as in RPE after training. Jumps height was greater during the matches (p< 0.013) and there were no differences in the number of jumps. There was a positive correlation between the number of jumps during matches and PRS before matches (r= 0.336, p= 0.015) and a negative correlation between the number of jumps during training and pre-training PRS (r= -0.318, p= 0.002). We conclude that the recovery period proposed by the team proved to be sufficient for the athletes to maintain the same condition for returning to training. This information can assist physical trainers to prescribe training loads for the return to training.


2009 ◽  
Vol 23 (5) ◽  
pp. 1489-1495 ◽  
Author(s):  
Paul G Montgomery ◽  
Daniel J Green ◽  
Naroa Etxebarria ◽  
David B Pyne ◽  
Philo U Saunders ◽  
...  

2012 ◽  
Vol 22 (2) ◽  
pp. 117-130 ◽  
Author(s):  
Steven Gastinger ◽  
Guillaume Nicolas ◽  
Anthony Sorel ◽  
Hamid Sefati ◽  
Jacques Prioux

The aim of this article was to compare 2 portable devices (a heart-rate monitor and an electromagnetic-coil system) that evaluate 2 different physiological parameters—heart rate (HR) and ventilation (VE)—with the objective of estimating energy expenditure (EE). The authors set out to prove that VE is a more pertinent setting than HR to estimate EE during light to moderate activities (sitting and standing at rest and walking at 4, 5, and 6 km/hr). Eleven healthy men were recruited to take part in this study (27.6 ± 5.4 yr, 73.7 ± 9.7 kg). The authors determined the relationships between HR and EE and between VE and EE during light to moderate activities. They compared EE measured by indirect calorimetry (EEREF) with EE estimated by HR monitor (EEHR) and EE estimated by electromagnetic coils (EEMAG) in upright sitting and standing positions and during walking exercises. They compared EEREF with EEHR and EEMAG. The results showed no significant difference between the values of EEREF and EEMAG. However, they showed several significant differences between the values of EEREF and EEHR (for standing at rest and walking at 5 and 6 km/hr). These results showed that the electromagnetic-coil system seems to be more accurate than the HR monitor to estimate EE at rest and during exercise. Taking into consideration these results, it would be interesting to associate the parameters VE and HR to estimate EE. Furthermore, a new version of the electromagnetic-coil device was recently developed and provides the possibility to perform measurement under daily life conditions.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Michael J. Duncan ◽  
Neil D. Clarke

The aim of this study was to examine the effect of acuteRhodiola rosea(R. rosea) ingestion on substrate utilisation, mood state, RPE, and exercise affect. Ten males (mean age ± S.D. = 26 ± 6 years) completed two 30-minute cycling trials at an intensity of 70% ofV˙O2max⁡following ingestion of either 3 mg·kg−1body mass ofR. roseaor placebo using a double-blind, crossover design. During exercise, heart rate and RPE were recorded. Participants completed measures of mood state and exercise affect before and after exercise. Expired air samples were taken during exercise to determine substrate utilisation. Repeated measures analysis of variance indicated that RPE was significantly lower at 30 minutes into exercise versus placebo (P=0.003). Perceptions of arousal (P=0.05) and pleasure were significantly higher after exercise withR. roseacompared to placebo (P=0.003). Mood state scores for vigor were also higher inR. roseacondition compared to placebo (P=0.008). There were no significant differences in energy expenditure, carbohydrate, or fat oxidation between conditions (P>0.05). Ingestion ofR. roseafavourably influenced RPE and exercise affect without changes in energy expenditure or substrate utilization during 30-minute submaximal cycling performance.


2010 ◽  
Vol 20 (6) ◽  
pp. 487-495 ◽  
Author(s):  
Jeanne F. Nichols ◽  
Hilary Aralis ◽  
Sonia Garcia Merino ◽  
Michelle T. Barrack ◽  
Lindsay Stalker-Fader ◽  
...  

There is a growing need to accurately assess exercise energy expenditure (EEE) in athletic populations that may be at risk for health disorders because of an imbalance between energy intake and energy expenditure. The Actiheart combines heart rate and uniaxial accelerometry to estimate energy expenditure above rest. The authors’ purpose was to determine the utility of the Actiheart for predicting EEE in female adolescent runners (N = 39, age 15.7 ± 1.1 yr). EEE was measured by indirect calorimetry and predicted by the Actiheart during three 8-min stages of treadmill running at individualized velocities corresponding to each runner’s training, including recovery, tempo, and 5-km-race pace. Repeated-measures ANOVA with Bonferroni post hoc comparisons across the 3 running stages indicated that the Actiheart was sensitive to changes in intensity (p < .01), but accelerometer output tended to plateau at race pace. Pairwise comparisons of the mean difference between Actiheart- and criterion-measured EEE yielded values of 0.0436, 0.0539, and 0.0753 kcal · kg−1 · min−1 during recovery, tempo, and race pace, respectively (p < .0001). Bland–Altman plots indicated that the Actiheart consistently underestimated EEE except in 1 runner’s recovery bout. A linear mixed-model regression analysis with height as a covariate provided an improved EEE prediction model, with the overall standard error of the estimate for the 3 speeds reduced to 0.0101 kcal · kg−1 · min−1. Using the manufacturer’s equation that combines heart rate and uniaxial motion, the Actiheart may have limited use in accurately assessing EEE, and therefore energy availability, in young, female competitive runners.


2008 ◽  
Vol 4 (1) ◽  
pp. 33-40 ◽  
Author(s):  
Cristen L. Harris ◽  
Valerie A. George

Inaccurate estimations of energy intake (EI) and energy expenditure (EE) may ultimately affect body weight. The purpose of this study was to evaluate accuracy of estimated EI and EE among males in reference to exercise and rest using a counterbalanced, crossover, repeated-measures design. Participants ( N = 80) were recruited from a large, urban university in South Florida. Exercise consisted of walking on a treadmill for 60 min at 65% age-predicted maximum heart rate. Food intake was evaluated immediately following exercise and rest. Participants underestimated EI (kcal) on both the exercise ( M = 435, SEM = 69) and rest days ( M = 439, SEM = 54), overestimated EE (kcal) for exercise ( M = 129, SEM = 44), and underestimated EE for rest ( M = 54, SEM = 10). Greater accuracy in estimating EE for exercise was significantly ( p < .05) associated with higher dietary restraint. The findings suggest that among sedentary males, there is an inability to accurately estimate calories, which has the potential to influence behaviors that affect weight management.


Author(s):  
Primož Pori ◽  
Maja Pori ◽  
Tina Jarc Šifrar ◽  
Borut Pistotnik

Workouts on Freestyler™ board are performed with stretching elastic tubes which are attached to arms and legs. The aim of the study was to investigate the effects of exercises with Freestyler™ elastic tubes of different resistance on heart rate frequency and prediction of energy expenditure. Eleven males (age 23.4 ± 1.1 years; height 181.6 ± 3.1 cm; weight 81.4 ± 4.9 kg) participated in the study. Effort was assessed with measuring heart rate (HR) frequency. To calculate maximum HR frequency (HRmax) an intermittent Fitness test 30-15 (Buchheit, Haddad, Millet, Lepretre, Newton and Ahmaidi, 2009) was used. Predicted energy expenditure was evaluated with Keytel et al. (2005) formula. One-way analysis of variance - repeated measures was used to analyse the effects of exercises with elastic tubes of different resistance. The results shows that both in relative HR frequency (% HRmax) (F(4, 40) = 161, 906; p = .000) and predicted energy expenditure (F(4, 40) = 151, 677; p = .000) there are statistically significant differences when performing exercises with elastic tubes of different resistance. It could be concluded that doing the same exercises with higher and higher resistance elastic tubes on the Freestyler™ board, could increase the % HRmax (from 19% to 43%) and predicted energy exposure (from 33% to 71%), compared to no additional resistance


2006 ◽  
Vol 38 (Supplement) ◽  
pp. S463
Author(s):  
Mia K. Newlin ◽  
Jonathan E. Wingo ◽  
Matthew S. Ganio ◽  
Jennifer L. Trilk ◽  
Kirk J. Cureton

2013 ◽  
Vol 82 (1) ◽  
pp. 103-107 ◽  
Author(s):  
De-Zhang Lu ◽  
Hong-Gang Fan ◽  
Sheng Jiang ◽  
Li-Juan Tan ◽  
Shi-Ming Yu ◽  
...  

This study focused on anaesthesia and cardiopulmonary effects of tiletamine-zolazepam/xylazine/tramadol in miniature pigs and its effects on endothelium-derived vasoactive factors. A total of 14 eight-month-old Chinese experimental miniature pigs were used in this study. Tiletamine-zolazepam (3.5 mg·kg-1), xylazine (1.32 mg·kg-1) and tramadol (1.8 mg·kg-1) were administered i.m.; blood pressure and heart rate were recorded. At the same time, blood was collected through precaval vein, and nitric oxide, endothelin, 6-keto-PGF1α and thromboxanes B2 were determined by colorimetry and radioimmunoassay. The mean times to dorsal recumbency, duration of immobilization, standing and walking were 2.26 ± 0.72, 87.57 ± 9.61, 25.63 ± 12.55 and 36.70 ± 14.53 min, respectively. Blood pressure was significantly changed at 10 and 80 min (P < 0.01), and the heart rate ranged from 89 to 134 bpm without episodes of severe bradycardia or tachycardia. Significantly positive correlation was observed between endothelin, thromboxanes B2 and blood pressure as well as the heart rate (P < 0.05). There was negative correlation between PGI2 and blood pressure as well as heart rate (P < 0.05). The results showed that endothelin, 6-keto-PGF1α and thromboxanes B2 participated in the changing of cardiopulmonary parameters which were caused by tiletamine-zolazepam-xylazine-tramadol anaesthesia in miniature pigs, and the 6-keto-PGF1α, ET and TXB2 concentrations in plasma participated in the changing of blood pressures during anaesthesia. Therefore, we can recommend tiletamine-zolazepam/xylazine/tramadol for anaesthesia in pigs, and this study also contributes to the evaluation of the effect of endothelium-derived vasoactive factors during anaesthesia.


Sign in / Sign up

Export Citation Format

Share Document