scholarly journals Assessing biological stability of drinking water produced by reverse osmosis and remineralisation : method development and application

2021 ◽  
Author(s):  
Mohaned Sousi
2020 ◽  
Vol 186 ◽  
pp. 116317
Author(s):  
Mohaned Sousi ◽  
Gang Liu ◽  
Sergio G. Salinas-Rodriguez ◽  
Lihua Chen ◽  
Jos Dusseldorp ◽  
...  

2014 ◽  
Vol 4 (2) ◽  
pp. 467-476
Author(s):  
Nisha Sharma ◽  
Jaspal Singh ◽  
Barjinder Kaur

Radionuclides (uranium, thorium, radium, radon gas etc.) are found naturally in air, water, soil and rock. Everyday, we ingest and inhale these radionuclides through the air we breathe and through food and water we take. Out of the internal exposure via ingestion of radionuclides, water contributes the major portion. The natural radioactivity of water is due to the activity transfer from bed rock and soils. In our surveys carried out in the past few years, we have observed high concentrations of uranium and total dissolved solids (TDS) in drinking waters of some southern parts of Punjab State exceeding the safe limits recommended by national and international agencies. The main drinking water source is the underground water procured from different depths. Due to the highly saline taste, disorders in their digestive systems and other ailments, people are installing reverse osmosis (RO) systems in their houses. Some RO systems have been installed on commercial basis. The state government is also in the process of installing community RO systems at the village level. As high values of uranium are also undesired and may pose health hazards due to radioactivity and toxicity of uranium, we have conducted a survey in the field to study the performance of various RO systems for removal of uranium and TDS. Water samples from about forty RO systems from Faridkot, Mansa, Bathinda and Amritsar districts of Punjab State were collected and analyzed. Our results show that some RO systems are able to remove more than 99% of uranium in the underground waters used for drinking purposes. TDS values are also reduced considerably to the desired levels. So RO systems can be used to avoid the risk of unduly health problems posed by high concentrations of uranium and TDS in drinking water.


2011 ◽  
Vol 11 (1) ◽  
pp. 107-112 ◽  
Author(s):  
A. Grefte ◽  
M. Dignum ◽  
S. A. Baghoth ◽  
E. R. Cornelissen ◽  
L. C. Rietveld

To guarantee a good water quality at the consumer’s tap, natural organic matter (NOM) should be (partly) removed during drinking water treatment. The objective of this research is to measure the effect of NOM removal by ion exchange on the biological stability of drinking water. Experiments were performed in two lanes of the pilot plant of Weesperkarspel in the Netherlands. The lanes consisted of ozonation, softening, biological activated carbon filtration and slow sand filtration. Ion exchange in fluidized form was used as pre-treatment in one lane and removed 50% of the dissolved organic carbon (DOC); the other lane was used as reference. Compared to the reference lane, the assimilable organic carbon (AOC) concentration of the finished water in the lane pretreated by ion exchange was 61% lower. The biofilm formation rate of the finished water was decreased with 70% to 2.0 pg ATP/cm2.day. The achieved concentration of AOC and the values of the biofilm formation rate with ion exchange pre-treatment showed that the biological stability of drinking water can be improved by extending a treatment plant with ion exchange, especially when ozonation is involved as disinfection and oxidation step.


Membranes ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 40
Author(s):  
Latifah Abdul Ghani ◽  
Nora’aini Ali ◽  
Ilyanni Syazira Nazaran ◽  
Marlia M. Hanafiah

Seawater desalination is an alternative technology to provide safe drinking water and to solve water issues in an area having low water quality and limited drinking water supply. Currently, reverse osmosis (RO) is commonly used in the desalination technology and experiencing significant growth. The aim of this study was to analyze the environmental impacts of the seawater reverse osmosis (SWRO) plant installed in Kampung Pantai Senok, Kelantan, as this plant was the first installed in Malaysia. The software SimaPro 8.5 together with the ReCiPe 2016 database were used as tools to evaluate the life cycle assessment (LCA) of the SWRO plant. The results showed that the impact of global warming (3.90 kg CO2 eq/year) was the highest, followed by terrestrial ecotoxicity (1.62 kg 1,4-DCB/year) and fossil resource scarcity (1.29 kg oil eq/year). The impact of global warming was caused by the natural gas used to generate the electricity, mainly during the RO process. Reducing the environmental impact can be effectively achieved by decreasing the electricity usage for the seawater desalination process. As a suggestion, electricity generation can be overcome by using a high-flux membrane with other suitable renewable energy for the plant such as solar and wind energy.


2013 ◽  
Vol 6 (1) ◽  
pp. 1-10 ◽  
Author(s):  
A. Grefte ◽  
M. Dignum ◽  
E. R. Cornelissen ◽  
L. C. Rietveld

Abstract. To guarantee a good water quality at the customers tap, natural organic matter (NOM) should be (partly) removed during drinking water treatment. The objective of this research was to improve the biological stability of the produced water by incorporating anion exchange (IEX) for NOM removal. Different placement positions of IEX in the treatment lane (IEX positioned before coagulation, before ozonation or after slow sand filtration) and two IEX configurations (MIEX® and fluidized IEX (FIX)) were compared on water quality as well as costs. For this purpose the pre-treatment plant at Loenderveen and production plant Weesperkarspel of Waternet were used as a case study. Both, MIEX® and FIX were able to remove NOM (mainly the HS fraction) to a high extent. NOM removal can be done efficiently before ozonation and after slow sand filtration. The biological stability, in terms of assimilable organic carbon, biofilm formation rate and dissolved organic carbon, was improved by incorporating IEX for NOM removal. The operational costs were assumed to be directly dependent of the NOM removal rate and determined the difference between the IEX positions. The total costs for IEX for the three positions were approximately equal (0.0631 € m−3), however the savings on following treatment processes caused a cost reduction for the IEX positions before coagulation and before ozonation compared to IEX positioned after slow sand filtration. IEX positioned before ozonation was most cost effective and improved the biological stability of the treated water.


2017 ◽  
Vol 13 (3) ◽  
Author(s):  
Suhadi Prayitno

Cases, concerns and complaints in public about refill drinking water,  low businessmen DAMIU are checked routinely product processed as well as the mandate of the Consumer Protection Act, Kepmerindag RI and Permenkes RI on monitoring refill drinking water background for the author to conduct research. Purpose to describe the bacteriological quality of refill drinking water in terms of disinfection method used in District Ngawi. This method is descriptive study and cluster sampling to 49 samples DAMIU in District Ngawi with the results of the method used, namely ultraviolet disinfection, ozonation and reverse  osmosis. The results bacteriological quality (total coliforms) of any disinfection method shows a different picture, which shows the method of disinfection reverse osmosis bacteriological quality with the percentage of 50.00%, followed by ozonation method of 46.15% and the latter by the ultraviolet method percentage value 44.12 %. The ability of any reduction in total coliform disinfection method shows a different picture, in which the reverse osmosis method of disinfection showed total coliform reduction percentage of 94.08%, followed by ozonation method of 91.46% and the latter by the ultraviolet method percentage value 86.09%. The conclusion willingness, support and cooperation of all stakeholders is needed to improve the supervision, guidance and inspection of the quality of refill drinking water in Ngawi. Key word : water, disinfection, coliform


Sign in / Sign up

Export Citation Format

Share Document