Performance Study of Some Reverse Osmosis Systems for Removal of Uranium and Total Dissolved Solids in Underground Waters of Punjab State, India

2014 ◽  
Vol 4 (2) ◽  
pp. 467-476
Author(s):  
Nisha Sharma ◽  
Jaspal Singh ◽  
Barjinder Kaur

Radionuclides (uranium, thorium, radium, radon gas etc.) are found naturally in air, water, soil and rock. Everyday, we ingest and inhale these radionuclides through the air we breathe and through food and water we take. Out of the internal exposure via ingestion of radionuclides, water contributes the major portion. The natural radioactivity of water is due to the activity transfer from bed rock and soils. In our surveys carried out in the past few years, we have observed high concentrations of uranium and total dissolved solids (TDS) in drinking waters of some southern parts of Punjab State exceeding the safe limits recommended by national and international agencies. The main drinking water source is the underground water procured from different depths. Due to the highly saline taste, disorders in their digestive systems and other ailments, people are installing reverse osmosis (RO) systems in their houses. Some RO systems have been installed on commercial basis. The state government is also in the process of installing community RO systems at the village level. As high values of uranium are also undesired and may pose health hazards due to radioactivity and toxicity of uranium, we have conducted a survey in the field to study the performance of various RO systems for removal of uranium and TDS. Water samples from about forty RO systems from Faridkot, Mansa, Bathinda and Amritsar districts of Punjab State were collected and analyzed. Our results show that some RO systems are able to remove more than 99% of uranium in the underground waters used for drinking purposes. TDS values are also reduced considerably to the desired levels. So RO systems can be used to avoid the risk of unduly health problems posed by high concentrations of uranium and TDS in drinking water.

2019 ◽  
Vol 7 (1) ◽  
pp. 11-16
Author(s):  
Abdulkhaleq K Mahmood ◽  
Ali A Kamal ◽  
Ako R Hama

The scarcity of safe drinking water is one of the problems faced by the majority of cities in the world. Kirkuk city is one of these cities, which suffer from a shortage of drinking water. People have adopted the use of different rooftop tanks to overcome this problem. This research focuses on studying the effect of storage time on the five main characteristics of drinking water, which include, acid index (pH), electrical conductivity (EC), total suspended solids (TSS), total dissolved solids (TDS), and turbidity (Tr). Three types of tanks were used predominantly (galvanized metal, plastic, and aluminum tanks). By analyzing the results, the characteristics of three samples of municipal source water obtained. Three samples were taken from each tank at different periods (4, 8, and 12 days). The results showed that the storage time affected the characteristics of drinking water. These characteristics differed from one tank to another. Metal tanks showed an increase in total dissolved solids, due to the evaporation process, even as plastic and aluminum tanks showed an increase in pH. The properties of all storage water tanks changed with times, but overall, the results were within the Iraqi limitation for drinking water. It was not easy to only depend on the results of this study to believe that any one type of water tank was better than the other, as the values of most of the variables studied had varied from one type to other. However, many studies have indicated a number of health risks, and most significantly with regard to plastic tanks, which are said to contain dangerous organic compounds that can be transferred to water. Metal tanks can cause zinc leakage, caused by a number of environmental factors at high levels. Aluminum tanks also can have an effect on the water in tanks.


Desalination ◽  
2009 ◽  
Vol 249 (1) ◽  
pp. 217-223 ◽  
Author(s):  
Romain Broséus ◽  
John Cigana ◽  
Benoit Barbeau ◽  
Catherine Daines-Martinez ◽  
Hervé Suty

2013 ◽  
Vol 726-731 ◽  
pp. 3538-3541
Author(s):  
Kun Xiao ◽  
Chang Chun Zou ◽  
Biao Xiang

In order to research the groundwater quality of the Taikang Formation in Tertiary in west of Daqing Oilfield, resistivity logging data of 140 wells in the study area were analyzed to forecast the groundwater total dissolved solids (TDS) distribution of the plane. When the resistivity logging value (Rt) of the Taikang Formation in Tertiary is above 45Ω.m and its corresponding value of Formation water TDS is below 1000 mg/L, the quality of groundwater accords with life standards for drinking. The south area of Hongweixing well area and the east of Xishuiyuan well area, including Ranghulu, Qianjincun, Dulitun and Nanshuiyuan well area are favorable for high quality groundwater. The research provides the evidences to evaluate the groundwater quality in west Daqing Oilfield and determine specific well location, improving the efficiency of exploring the underground drinking water.


2004 ◽  
Vol 49 (9) ◽  
pp. 321-328 ◽  
Author(s):  
P. Piriou ◽  
E.D. Mackey ◽  
I.H. Suffet ◽  
A. Bruchet

Chlorinous flavors at the tap are the leading cause of customers' complaints and dissatisfaction with drinking water. To characterize consumer perception and acceptance to chlorinous tastes, extensive taste testing was performed with both trained panelists and average consumers. Taste testing with trained panelists showed that chlorine perception is underestimated by disinfectant flavor thresholds reported in the literature. However, trained panelists significantly overestimate the average consumer's ability to perceive chlorine. In addition, consumer perception seems to be influenced by the chlorination practices of the country they live in. Among water quality characteristics that may influence chlorine perception, temperature was not found to induce any significant change. The influence of total dissolved solids (TDS) on chlorine perception remains unclear and, as reported elsewhere, background tastes such as musty, may significantly impact chlorine threshold.


Author(s):  
Israel Sebsibe ◽  
Birhanu Degaga ◽  
Gezahegn Feye ◽  
Tsige Tekle

Abstract Drinking water is the major source of bacteria pathogens in developing countries along with poor sanitation and contamination of food with a pathogen. More than half of the population of the country uses unimproved sanitation facilities while 36% of them practiced open defecation. The aim of the study was to investigate the suitability of public water for drinking. The study is designed to include a survey of 90 respondents and experimental analysis of 170 water samples from households and reservoirs. Water quality parameters, such as temperature, electrical conductivity, turbidity, total dissolved solids, and bacteriological parameters like total coliforms (TC) and fecal coliforms (FC) were determined. Many of the respondents (88.8%) remarked that the water has no smells, tastes, and color. The experimental analysis confirmed that temperature (19.7 °C), electrical conductivity (269.63 μS/cm), turbidity (1.17 NTU), and total dissolved solids (134.3 mg/L) were found below the prescribed limit of World Health Organization guidelines for drinking water. Total coliforms (9.29 CFU/100 mL) and fecal coliforms (5.07 CFU/100 mL) were detected from pipe water sources during the wet season showing non-compliance with the guidelines. The reservoir samples were free from bacterial contamination. The main point of drinking water contamination was the household where unsafe water handling practice was a common habit in the study area. Hence, awareness conception training on safe water handling practices is highly recommended for the communities.


Author(s):  
Anupam Singhal ◽  
Rajiv Gupta ◽  
Arun Singh

The quality of groundwater and surface water bodies have been analyzed globally and showed that 23% of primary drinking water sources have more than permissible limits of pollutants’ concentration. A major part of the world suffers from high concentrations of Nitrate, Fluoride and total dissolved solids (TDS) in drinking water. Therefore, the present work focuses on the treatment of these three parameters. There are many processes available to remove and reduce the higher concentration of the aforesaid pollutants in water with advantages and disadvantages. One of the main disadvantages of these processes is the sustainability and availability of treating materials. In this regard, the work explores different agricultural materials (nine to be exact) for reduction of Fluoride, Nitrate and TDS in water. It is found that most of the materials have the potential to reduce either of one contaminant. However, only potato gel has shown potential in reduction of all three contaminants', i.e. Fluoride, Nitrate and TDS, concentration. The Isotherm plots indicate that Nitrate and TDS biosorption mechanism follows the Langmuir Isotherm while Fluoride biosorption follows the Freundlich Isotherm. Optimization is carried out, using batch and continuous study, in terms of time and mass of adsorbent against the concentration of the contaminant. Adsorption column tests indicate the reduction of 89%, 92% and 86% in the concentration of Fluoride, Nitrate and TDS respectively by potato gel.


2017 ◽  
Vol 13 (15) ◽  
pp. 69
Author(s):  
Sohounou Marc ◽  
Vissin Expédit Wilfrid ◽  
Sintondji Luc Olivier ◽  
Houssou Christophe S. ◽  
Agbossou K. Euloge ◽  
...  

Water, source of life, is also a source of disease when it is polluted. The aim of this study is to analyze the physicochemical quality and the bacteriological quality of the wells, boreholes and tank for drinking water in the Commune of Allada. The methodology is based on the collection of data, data processing and analysis carried out at the Laboratory for Quality Control of Water and Food (LCQEA) of the Ministry of Health. From the water sampling carried out at three (03) traditional wells, two (02) boreholes, two (02) tanks and water of river (02), bacteriological and physicochemical analysis were performed. The results showed that pH is higher at the tank than other water sources. Well 3 (P3) has a very high electrical conductivity (EC) which was 384.95 μS / cm and 192.47 mg / L for total dissolved solids (TDS). The tank 2 exhibited high value in pH 9.14; 71.72 (μS / cm) for the electrical conductivity (CE) and 35.86 mg / L, in total dissolved solids (TDS). Well 2 (P2) has a high turbidity of 4.53 (NTU) at all analyzed water points. The concentration of iron, copper nickel and cobalt remains low(less than 0.4 mg / L).Wells 2 and tank 1 are concentrated in lead, respectively 20.75mg / L and 13.71mg / L. Tank 1 and 2 have a high concentration of cadmium compared to other water points. The presence of Escherichia coli with a high concentration at home SONEB (39 CFU) and at well 2 (7.10 2 ) was found. In view of these results some recommendations were made.


Sign in / Sign up

Export Citation Format

Share Document