Technological Analysis of the Orientation of the Pitched Icelandic Turf Roof to the Cardinal Points and their Effect on the Stability of the Vegetative Layers

2014 ◽  
Vol 1041 ◽  
pp. 19-22 ◽  
Author(s):  
Petr Selnik ◽  
Klara Necadova ◽  
Martin Mohapl

This article is focused on the assessment of the pitched turf green roof to the cardinal points, its permanent sustainable functional condition and investigation of a possible damage caused by local climate. The solution of these problems is the crucial factor in next development, use and expansion of this type of roofing in European broader range. This study of the roof construction that was made in Iceland offers conclusion based on quick changes of the local climate conditions and demanding extreme weather impacts. The main aim of this research is proposed the right possible solution and design of this construction including dealing with the details, select the convenient orientation to the cardinal points and surroundings to provide long-term stability of this construction.

1979 ◽  
Vol 42 (04) ◽  
pp. 1135-1140 ◽  
Author(s):  
G I C Ingram

SummaryThe International Reference Preparation of human brain thromboplastin coded 67/40 has been thought to show evidence of instability. The evidence is discussed and is not thought to be strong; but it is suggested that it would be wise to replace 67/40 with a new preparation of human brain, both for this reason and because 67/40 is in a form (like Thrombotest) in which few workers seem to use human brain. A �plain� preparation would be more appropriate; and a freeze-dried sample of BCT is recommended as the successor preparation. The opportunity should be taken also to replace the corresponding ox and rabbit preparations. In the collaborative study which would be required it would then be desirable to test in parallel the three old and the three new preparations. The relative sensitivities of the old preparations could be compared with those found in earlier studies to obtain further evidence on the stability of 67/40; if stability were confirmed, the new preparations should be calibrated against it, but if not, the new human material should receive a calibration constant of 1.0 and the new ox and rabbit materials calibrated against that.The types of evidence available for monitoring the long-term stability of a thromboplastin are discussed.


Author(s):  
Mark Kersten

Abstract Does the potential investigation into Palestine by the International Criminal Court (ICC) threaten the chances of a lasting ‘peace’ between Israel and Palestine? This article endeavours to answer that question and critically assesses claims that the Court could undermine peace in the Middle East. I first examine the key claims made in the so-called ‘peace versus justice’ debate. I then outline some of the specific arguments made in the context of a possible ICC investigation in Palestine that touch upon concerns over the Court’s impacts on peace processes and negotiations. Following this, I try to assess critically the validity of these claims, arguing that while it would be wrong to conclude that the ICC will invariably have positive impacts on efforts to establish peace, there is no evidence that the Court will undermine whatever ‘peace’ is currently on offer for Palestinians and Israelis. On the contrary, this ‘peace’ may itself be a threat to resolving the conflict peaceably and to long-term stability in the region. Finally, I conclude the article with some reflections on the peace-justice debate and its applicability to the Israel–Palestine situation.


1969 ◽  
Vol 12 (2) ◽  
pp. 351-361 ◽  
Author(s):  
Maurice I. Mendel ◽  
Robert Goldstein

The early components of the averaged electroencephalic response (AER) were examined at three-hour intervals in eight normal hearing adults over a single, sleepless 24-hour span. During each of the eight sessions, three series of clicks at 50 dB SL were presented to the right ear of the subject as he sat reading. 1024 clicks at the rate of 9.6/sec were used in obtaining each averaged response. Electroencephalic activity was recorded from an electrode on the vertex referred to the left earlobe. The response pattern was very stable, characterized by a polyphasic configuration with mean peak latencies of (P o ) 13.3 msec, (N a ) 22.0 msec, (P a ) 32.3 msec, and (N b ) 45.1 msec. An earlier negative peak (N o ) with a mean peak latency of 8.3 msec occurred in many of the responses. At the conclusion of the 24-hour span, three of the subjects were tested with the same stimuli during various stages of sleep. The early components of the AER remained consistent even during sleep. Threshold searches were successfully carried out on two of the sleeping subjects. The long-term stability of the early components of the AER in the awake and sleep states makes them practical as a response index for electroencephalic audiometry. Their characteristics are more compatible with a neurogenic than with a myogenic theory of their origin.


2021 ◽  
Vol 15 (1) ◽  
pp. 2
Author(s):  
Cristina Martín-Sabroso ◽  
Mario Alonso-González ◽  
Ana Fernández-Carballido ◽  
Juan Aparicio-Blanco ◽  
Damián Córdoba-Díaz ◽  
...  

Accumulation of cystine crystals in the cornea of patients suffering from cystinosis is considered pathognomonic and can lead to severe ocular complications. Cysteamine eye drop compounded formulations, commonly prepared by hospital pharmacy services, are meant to diminish the build-up of corneal cystine crystals. The objective of this work was to analyze whether the shelf life proposed for six formulations prepared following different protocols used in hospital pharmacies is adequate to guarantee the quality and efficacy of cysteamine eye drops. The long-term and in-use stabilities of these preparations were studied using different parameters: content of cysteamine and its main degradation product cystamine; appearance, color and odor; pH and viscosity; and microbiological analysis. The results obtained show that degradation of cysteamine was between 20% and 50% after one month of storage in the long-term stability study and between 35% and 60% in the in-use study. These data confirm that cysteamine is a very unstable molecule in aqueous solution, the presence of oxygen being the main degradation factor. Saturation with nitrogen gas of the solutions offers a means of reducing cysteamine degradation. Overall, all the formulae studied presented high instability at the end of their shelf life, suggesting that their clinical efficacy might be dramatically compromised.


2013 ◽  
Vol 23 (11) ◽  
pp. 2129-2154 ◽  
Author(s):  
HÉLÈNE BARUCQ ◽  
JULIEN DIAZ ◽  
VÉRONIQUE DUPRAT

This work deals with the stability analysis of a one-parameter family of Absorbing Boundary Conditions (ABC) that have been derived for the acoustic wave equation. We tackle the problem of long-term stability of the wave field both at the continuous and the numerical levels. We first define a function of energy and show that it is decreasing in time. Its discrete form is also decreasing under a Courant–Friedrichs–Lewy (CFL) condition that does not depend on the ABC. Moreover, the decay rate of the continuous energy can be determined: it is exponential if the computational domain is star-shaped and this property can be illustrated numerically.


2021 ◽  
pp. 1-27
Author(s):  
Yichen Bao ◽  
Kai Liu ◽  
Quan Zheng ◽  
Lulu Yao ◽  
Yufu Xu

Abstract Pickering emulsion is a new type of stable emulsion made by ultra-fine solid particles instead of traditional surfactants as stabilizers, which has received widespread attention in recent years. The preparation methods of stator-rotor homogenization, high-pressure homogenization, and ultrasonic emulsification were compared with others in this work. The main factors affecting the stability of Pickering emulsion are the surface humidity of the solid particles, the polarity of the oil phase, and the oil-water ratio. These factors could affect the nature of the solid particles, the preparation process of Pickering emulsion and the external environment. Consequently, the long-term stability of Pickering emulsion is still a challenge. The tribological investigations of Pickering emulsion were summarized, and the multifunctional Pickering emulsion shows superior prospects for tribological applications. Moreover, the latest development of Pickering emulsion offers a new strategy for smart lubrication in the near future.


2012 ◽  
Vol 2012 (CICMT) ◽  
pp. 000371-000376 ◽  
Author(s):  
Marina Santo Zarnik ◽  
Darko Belavic

This paper discusses the stability of a piezoresistive, LTCC-based, pressure sensor that was designed for measurements in a low-pressure range below 100 mbar. The intrinsic stability of the sensor's offset was evaluated at a constant ambient temperature and different conditions regarding the atmospheric humidity. The sensors were also subjected to functional fatigue tests, which included a full-scale and an overload pressure cycling. The results of the fatigue testing revealed the vulnerability of the sensor's structure from the point of view of the long-term stability and the life-cycle. Nevertheless, the stability of the key characteristics of the prototype sensors was found to be satisfactory for accurate measurements in the low-pressure ranges.


1995 ◽  
Vol 377 ◽  
Author(s):  
Mohan K. Bhan

ABSTRACTWe have systematically investigated the effects of addition of sub-ppm levels of boron on the stability of a-Si:H films and p-i-n devices, deposited by PE-CVD technique. The films thus produced with appropriate amounts of boron, show a significant improvement in stability, when soaked under both AM 1.5 (short-term) as well as 10×sun (long-term) illumination conditions. The opto-electronic properties of the films are quite respectable It is concluded that boron compensates the native impurities by forming donor-acceptor pairs, which reduces the “fast” defects and hence the initial degradation of the films. It is also speculated that boron may also be improving the short-term stability, by reducing the recombination of light generated electrons and holes, by converting D° into D+ states. The long-term stability appears to get affected by hydrogen dilution which seems to reduce the amount of “slow” defects. As a result of B doping of i-layer, the initial conversion efficiency of the devices decreases. It is presumed that our devices may contain an enhanced level of boron impurity, than expected, making them as worse material and to degrade less.


2016 ◽  
Vol 21 (1) ◽  
pp. 67-74 ◽  
Author(s):  
Caroline Andrade Rocha ◽  
Renato Rodrigues de Almeida ◽  
José Fernando Castanha Henriques ◽  
Carlos Flores-Mir ◽  
Marcio Rodrigues de Almeida

Objective: To evaluate the stability of mesiodistal inclination of maxillary molars produced by a pendulum appliance, five years after completion of orthodontic treatment. Angulation changes were compared to an untreated sample. Methods: The sample consisted of 20 patients (14 females and 6 males) with Class II, Division 1 malocclusion that was treated through molar distalization with a pendulum appliance followed by cervical headgear and full fixed appliances. Maxillary molar inclination was evaluated through panoramic radiograph. The mean age at pretreatment was 14.3 ± 1.6 years, whereas at immediate post-treatment it was 18.6 ± 1.8 years, and at long-term post-treatment it was 23.8 ± 2.0 years. A control group of 16 untreated individuals with untreated normocclusion ranging in age from 12 to 17 years old were used as comparison group. Data were statistically analyzed with independent t-tests and ANOVA test followed by Tukey post-hoc tests. Results: Statistically significant differences were found between T1 (94.50) and T2 (98.80) as well as between T2 and T3 (94.70) for maxillary first molars. Maxillary second molars did not show any statistically significant positional changes during the evaluated time periods T1 (107.50), T2 (109.30) and T3 (106.90). Conclusion: Although maxillary first molars underwent distal crown inclination immediately after treatment, approximately five years thereafter their roots tended to upright close to the pretreatment positions.


2018 ◽  
Vol 3 (3) ◽  
pp. 143-151
Author(s):  
Sophie Huvelle ◽  
Marie Godet ◽  
Laurence Galanti ◽  
Mélanie Closset ◽  
Benoît Bihin ◽  
...  

AbstractBackgroundPiperacillin-Tazobactam is frequently infused in hospitals. The use of a generic version was considered after the out of stock of the brand name Tazocin®. The stability of 4 g of Tazocin®in 120 mL of dextrose 5 % (D5) was demonstrated during 35 days at 5 °C ± 3 °C after freezing (−20 °C) and microwave thawing (FMT). The aim of the study was to investigate and compare the long-term stability of Tazocin®and a generic product in the same conditions.MethodsFive polyolefin bags of 4 g of Piperacillin/Tazobactam®Sandoz and 5 bags of 4 g of Tazocin®were prepared under aseptic conditions in 120 mL of D5 and stored 3 months at 20 °C then thawed and stored 58 days at 5 ± 3 °C.Spectrophotometric absorbance at different wavelengths, pH measurement, visual and microscopic observations were also performed.The concentrations were measured by HPLC, at 211 nm for tazobactam and 230 nm for piperacilline.ResultsNo significant change in pH values or optic densities, no crystals were detected. The lower confidence limit at 95 % of the concentration for the solutions remains superior to 90 % of the initial concentration until 58 days of storage at 5 ± 3 °C.ConclusionUnder these conditions, 4 g/120 mL of Piperacillin/Tazobactam®Sandoz or Tazocin®in D5 infusion in polyolefin bags remains stable at least for 58 days at 5 ± 3 °C after FMT


Sign in / Sign up

Export Citation Format

Share Document