In Vitro Corrosion Behaviour of Metallic Dental Materials

2015 ◽  
Vol 1114 ◽  
pp. 258-265 ◽  
Author(s):  
Diana Maria Vrânceanu ◽  
Mihai Tarcolea ◽  
Ana Iulia Gherghilescu ◽  
Florin Miculescu ◽  
Mihai Cosmin Cotrut

Typical applications of metallic dental materials include metal-ceramic restorations, dental implants or orthodontic systems. Due to their contact with human tissues, corrosion resistance is one of the main requirements for dental materials. In the present paper, the corrosion behaviour in Fusayama Meyer artificial saliva solution (pH=5.2) on a selection of four different metallic dental materials (316 L steel, Au based alloy, cp-Ti, Ti6Al4V alloy) currently used in dentistry were investigated. The metallic dental materials have been investigated in terms of electrochemical analysis, chemical composition, morphology before and after corrosion, wettability and roughness. The results showed a hydrophilic behaviour in the case of Au based alloy, cp-Ti and Ti6Al4V alloy, and hydrophobic for 316L stainless steel. Considering the main electrochemical parameters, the cp-Ti alloy exhibited better corrosion resistance in artificial saliva with pH=5.2, followed by Au based alloy, Ti6Al4V alloy and 316L stainless steel. The main objective of the present paper was to evaluate the corrosion behaviour, as in important factor in the selection of metallic materials used in dentistry.

2013 ◽  
Vol 2013 ◽  
pp. 1-8
Author(s):  
Chao Zhang ◽  
Xinhua Sun

The corrosion resistance of laser-welded composite arch wire (CoAW) with Cu interlayer between NiTi shape memory alloy and stainless steel wire in artificial saliva with different acidities and loads was studied. It was found that both the solution pH and the stress had a significant influence on the corrosion behaviors of the CoAW samples. Decreasing the solution pH or increasing the loading stress caused the increase of Cu release and weight loss. The corroded morphology formed on the surfaces of the CoAW was the consequence under the combined effect of corrosion and stress.


Processes ◽  
2019 ◽  
Vol 7 (8) ◽  
pp. 506 ◽  
Author(s):  
Sadaqat Ali ◽  
Ahmad Majdi Abdul Rani ◽  
Riaz Ahmad Mufti ◽  
Farooq I. Azam ◽  
Sri Hastuty ◽  
...  

In the past, 316L stainless steel (SS) has been the material of choice for implant manufacturing. However, the leaching of nickel ions from the SS matrix limits its usefulness as an implant material. In this study, an efficient approach for controlling the leaching of ions and improving its properties is presented. The composition of SS was modified with the addition of boron and niobium, which was followed by sintering in nitrogen atmosphere for 8 h. The X-ray diffraction (XRD) results showed the formation of strong nitrides, indicating the diffusion of nitrogen into the SS matrix. The X-ray photoelectron spectroscopy (XPS) analysis revealed that a nitride layer was deposited on the sample surface, thereby helping to control the leaching of metal ions. The corrosion resistance of the alloy systems in artificial saliva solution indicated minimal weight loss, indicating improved corrosion resistance. The cytotoxicity assessment of the alloy system showed that the developed modified stainless steel alloys are compatible with living cells and can be used as implant materials.


Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 252
Author(s):  
Mariusz Hasiak ◽  
Beata Sobieszczańska ◽  
Amadeusz Łaszcz ◽  
Michał Biały ◽  
Jacek Chęcmanowski ◽  
...  

Microstructure, mechanical properties, corrosion resistance, and biocompatibility were studied for rapidly cooled 3 mm rods of Zr40Ti15Cu10Ni10Be25, Zr50Ti5Cu10Ni10Be25, and Zr40Ti15Cu10Ni5Si5Be25 (at.%) alloys, as well as for the reference 316L stainless steel and Ti-based Ti6Al4V alloy. Microstructure investigations confirm that Zr-based bulk metallic samples exhibit a glassy structure with minor fractions of crystalline phases. The nanoindentation tests carried out for all investigated composite materials allowed us to determine the mechanical parameters of individual phases observed in the samples. The instrumental hardness and elastic to total deformation energy ratio for every single phase observed in the manufactured Zr-based materials are higher than for the reference materials (316L stainless steel and Ti6Al4V alloy). A scratch tester used to determine the wear behavior of manufactured samples and reference materials revealed the effect of microstructure on mechanical parameters such as residual depth, friction force, and coefficient of friction. Electrochemical investigations in simulated body fluid performed up to 120 h show better or comparable corrosion resistance of Zr-based bulk metallic glasses in comparison with 316L stainless steel and Ti6Al4V alloy. The fibroblasts viability studies confirm the good biocompatibility of the produced materials. All obtained results show that fabricated biocompatible Zr-based materials are promising candidates for biomedical implants that require enhanced mechanical properties.


Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3270
Author(s):  
Sadaqat Ali ◽  
Muhammad Irfan ◽  
Usama Muhammad Niazi ◽  
Ahmad Majdi Abdul Rani ◽  
Imran Shah ◽  
...  

The powder metallurgy (PM) technique has been widely used for producing different alloy compositions by the addition of suitable reinforcements. PM is also capable of producing desireable mechanical and physical properties of the material by varying process parameters. This research investigates the addition of titanium and niobium in a 316L stainless steel matrix for potential use in the biomedical field. The increase of sintering dwell time resulted in simultaneous sintering and surface nitriding of compositions, using nitrogen as the sintering atmosphere. The developed alloy compositions were characterized using OM, FESEM, XRD and XPS techniques for quantification of the surface nitride layer and the nitrogen absorbed during sintering. The corrosion resistance and cytotoxicity assessments of the developed compositions were carried out in artificial saliva solution and human oral fibroblast cell culture, respectively. The results indicated that the nitride layer produced during sintering increased the corrosion resistance of the alloy and the developed compositions are non-cytotoxic. This newly developed alloy composition and processing technique is expected to provide a low-cost solution to implant manufacturing.


Alloy Digest ◽  
1995 ◽  
Vol 44 (6) ◽  

Abstract BioDur 316LS stainless steel is a modified version of Type 316L stainless steel to improve corrosion resistance for surgical implant applications. The alloy is vacuum arc remelted. This datasheet provides information on composition, physical properties, hardness, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-596. Producer or source: Carpenter.


Alloy Digest ◽  
2015 ◽  
Vol 64 (7) ◽  

Abstract EnduraMet 316LN stainless is a nitrogen strengthened version of Type 316L stainless steel. This datasheet provides information on composition, physical properties, and tensile properties as well as fracture toughness. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-1219. Producer or source: Carpenter Technology Corporation.


2015 ◽  
Vol 39 (3-4) ◽  
pp. 167-174
Author(s):  
Michal Latkiewicz ◽  
Halina Krawiec ◽  
Vincent Vignal ◽  
Paulina Erazmus-Vignal

Sign in / Sign up

Export Citation Format

Share Document