Improved corrosion resistance of 316L stainless steel by nanocrystalline and electrochemical nitridation in artificial saliva solution

2015 ◽  
Vol 359 ◽  
pp. 158-165 ◽  
Author(s):  
Jinlong Lv ◽  
Tongxiang Liang
Processes ◽  
2019 ◽  
Vol 7 (8) ◽  
pp. 506 ◽  
Author(s):  
Sadaqat Ali ◽  
Ahmad Majdi Abdul Rani ◽  
Riaz Ahmad Mufti ◽  
Farooq I. Azam ◽  
Sri Hastuty ◽  
...  

In the past, 316L stainless steel (SS) has been the material of choice for implant manufacturing. However, the leaching of nickel ions from the SS matrix limits its usefulness as an implant material. In this study, an efficient approach for controlling the leaching of ions and improving its properties is presented. The composition of SS was modified with the addition of boron and niobium, which was followed by sintering in nitrogen atmosphere for 8 h. The X-ray diffraction (XRD) results showed the formation of strong nitrides, indicating the diffusion of nitrogen into the SS matrix. The X-ray photoelectron spectroscopy (XPS) analysis revealed that a nitride layer was deposited on the sample surface, thereby helping to control the leaching of metal ions. The corrosion resistance of the alloy systems in artificial saliva solution indicated minimal weight loss, indicating improved corrosion resistance. The cytotoxicity assessment of the alloy system showed that the developed modified stainless steel alloys are compatible with living cells and can be used as implant materials.


2015 ◽  
Vol 1114 ◽  
pp. 258-265 ◽  
Author(s):  
Diana Maria Vrânceanu ◽  
Mihai Tarcolea ◽  
Ana Iulia Gherghilescu ◽  
Florin Miculescu ◽  
Mihai Cosmin Cotrut

Typical applications of metallic dental materials include metal-ceramic restorations, dental implants or orthodontic systems. Due to their contact with human tissues, corrosion resistance is one of the main requirements for dental materials. In the present paper, the corrosion behaviour in Fusayama Meyer artificial saliva solution (pH=5.2) on a selection of four different metallic dental materials (316 L steel, Au based alloy, cp-Ti, Ti6Al4V alloy) currently used in dentistry were investigated. The metallic dental materials have been investigated in terms of electrochemical analysis, chemical composition, morphology before and after corrosion, wettability and roughness. The results showed a hydrophilic behaviour in the case of Au based alloy, cp-Ti and Ti6Al4V alloy, and hydrophobic for 316L stainless steel. Considering the main electrochemical parameters, the cp-Ti alloy exhibited better corrosion resistance in artificial saliva with pH=5.2, followed by Au based alloy, Ti6Al4V alloy and 316L stainless steel. The main objective of the present paper was to evaluate the corrosion behaviour, as in important factor in the selection of metallic materials used in dentistry.


Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3270
Author(s):  
Sadaqat Ali ◽  
Muhammad Irfan ◽  
Usama Muhammad Niazi ◽  
Ahmad Majdi Abdul Rani ◽  
Imran Shah ◽  
...  

The powder metallurgy (PM) technique has been widely used for producing different alloy compositions by the addition of suitable reinforcements. PM is also capable of producing desireable mechanical and physical properties of the material by varying process parameters. This research investigates the addition of titanium and niobium in a 316L stainless steel matrix for potential use in the biomedical field. The increase of sintering dwell time resulted in simultaneous sintering and surface nitriding of compositions, using nitrogen as the sintering atmosphere. The developed alloy compositions were characterized using OM, FESEM, XRD and XPS techniques for quantification of the surface nitride layer and the nitrogen absorbed during sintering. The corrosion resistance and cytotoxicity assessments of the developed compositions were carried out in artificial saliva solution and human oral fibroblast cell culture, respectively. The results indicated that the nitride layer produced during sintering increased the corrosion resistance of the alloy and the developed compositions are non-cytotoxic. This newly developed alloy composition and processing technique is expected to provide a low-cost solution to implant manufacturing.


Alloy Digest ◽  
1995 ◽  
Vol 44 (6) ◽  

Abstract BioDur 316LS stainless steel is a modified version of Type 316L stainless steel to improve corrosion resistance for surgical implant applications. The alloy is vacuum arc remelted. This datasheet provides information on composition, physical properties, hardness, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-596. Producer or source: Carpenter.


Alloy Digest ◽  
2015 ◽  
Vol 64 (7) ◽  

Abstract EnduraMet 316LN stainless is a nitrogen strengthened version of Type 316L stainless steel. This datasheet provides information on composition, physical properties, and tensile properties as well as fracture toughness. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-1219. Producer or source: Carpenter Technology Corporation.


2013 ◽  
Vol 2013 ◽  
pp. 1-8
Author(s):  
Chao Zhang ◽  
Xinhua Sun

The corrosion resistance of laser-welded composite arch wire (CoAW) with Cu interlayer between NiTi shape memory alloy and stainless steel wire in artificial saliva with different acidities and loads was studied. It was found that both the solution pH and the stress had a significant influence on the corrosion behaviors of the CoAW samples. Decreasing the solution pH or increasing the loading stress caused the increase of Cu release and weight loss. The corroded morphology formed on the surfaces of the CoAW was the consequence under the combined effect of corrosion and stress.


Author(s):  
S. Kuroda ◽  
T. Fukushima ◽  
T. Kodama ◽  
M. Sasaki

Abstract 316L stainless steel and Hastelloy C alloy powders were sprayed by an HVOF apparatus onto mild steel substrates. The microstructure, pore size distribution, composition and corrosion resistance of thus obtained coatings were evaluated experimentally. Corrosion resistance in sea-water was examined by monitoring the impedance and corrosion potential of samples immersed in artificial sea-water at 300 K over a period of more than 3 months and also by polarization measurement. It was found that the stainless coatings composed mainly of plastically deformed particles and some splats which were molten at the impact. By increasing the combustion pressure, the porosity as measured by mercury porosimeter could be reduced to below 1%. In comparison, Hastelloy C deposits sprayed under the standard condition were so dense that its porosity could not be measured by the porosimeter. The polarization curve and the results of impedance monitoring both exemplified that the Hastelloy C coatings possess much superior corrosion resistance to the stainless coatings in sea-water, which was attributed to the higher density and better adhesion of the Ni-base alloy coatings.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6790
Author(s):  
Viera Zatkalíková ◽  
Juraj Halanda ◽  
Dušan Vaňa ◽  
Milan Uhríčik ◽  
Lenka Markovičová ◽  
...  

Plasma immersion ion implantation (PIII) of nitrogen is low-temperature surface technology which enables the improvement of tribological properties without a deterioration of the corrosion behavior of austenitic stainless steels. In this paper the corrosion properties of PIII-treated AISI 316L stainless steel surfaces are evaluated by electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PP) and exposure immersion tests (all carried out in the 0.9 wt. % NaCl solution at 37 ± 0.5 °C) and compared with a non-treated surface. Results of the three performed independent corrosion tests consistently confirmed a significant increase in the corrosion resistance after two doses of PIII nitriding.