Experimental Research on Resistance and Heat Transfer Properties of Corrugated Plate Air-Cooled Heat Exchanger

2011 ◽  
Vol 354-355 ◽  
pp. 153-158
Author(s):  
Xiao Qing Huang ◽  
Xu Zhang ◽  
Chun Guang Li

Experimental research on resistance and heat transfer properties of corrugated plate air-cooled heat exchanger under the condition of variable air and hot water flow rates has been conducted. The pressure drop and convection heat transfer coefficient correlation expressions both the air side and hot water side are acquired, where the Reynolds number for air side ranges from 401 to 6602 and the Reynolds number for water side ranges from 2536 to 19301 are adaptable.

2021 ◽  
Vol 6 (2) ◽  
pp. 41-52
Author(s):  
Mohd Rahimie Md Noor ◽  
Nur Syafiqah Hidayah Mohd Fauzi ◽  
Siti Nur Fadhilah Masrom ◽  
Mohd Azry Abdul Malek ◽  
Muhammad Firdaus Mustapha ◽  
...  

Heat exchangers are tools used to transfer thermal energy between two fluids (liquid or gas) by convection and conduction at different level of temperatures. Heat exchangers are the common equipment and employed in many different applications because of ability to withstand high temperatures and compactness. There are no intermixing or leakage occurred between two fluids during the heat transfer process as fluids are separated by walls of heat exchanger. The main objective of this project is to determine the heat exchanger effectiveness in heat transfer performance. This will be done by investigating the performance of five different angles of heat exchanger which are 150,300, 450, 600 and 750. The effectiveness of heat exchanger depends on the convection heat transfer coefficient of the fluid. Besides that, this project also aims to develop some parameters such as Nusselt number, Reynolds number and Prandtl number for evaluating the heat transfer. It is found that the Nusselt Number at angle of 150 is lower compared to angle of 750. Meanwhile, Reynolds number for angle 150 is higher than angle 750 which means that the type of flow produced by angle 150 is turbulent flow while for 750 angle is laminar flow. Hence, the overall result of this project proved that 150 is the best angle for heat exchanger in chimney because of higher velocity, higher volume flow rate, higher density of gas and higher LMTD. The relationship between Nusselt number and Reynolds number between different angles can be observed by plotting the graph using Maple Software.


Author(s):  
Julia Haltiwanger Nicodemus ◽  
Xiaoqi Huang ◽  
Emily Dentinger ◽  
Kyle Petitt ◽  
Joshua H. Smith

Abstract In this work, we investigate the effects of the width of an annular baffle region on natural convection heat transfer to an immersed, coiled heat exchanger in an otherwise quiescent sensible hot water storage tank. In experiments, the coiled heat exchanger sits in an annular region created by the tank wall and a straight, cylindrical baffle. The width of this baffle region is 1.5, 2, 3, or 4 times the heat exchanger diameter, These experiments are compared to each other and to corresponding control experiments with no baffle. In general, all baffles create considerable benefits over their respective control experiments, consistent with past studies. The considered metrics of heat transfer rate, fraction of energy discharged from the tank, and heat exchanger outlet temperature show that heat transfer is improved slightly by narrowing the baffle region. For example, relative to their respective controls, the energy extracted from the tank after 30 min of discharge in the 1.5D, 2D, 3D and 4D experiments is 23.2%, 20.8%, 18.1%, and 14.7% higher, respectively. This improvement in natural convection heat transfer as the baffle region narrows is attributed to the increasing thermal stratification observed in experiments with increasingly narrow baffle regions.


2019 ◽  
Vol 142 (5) ◽  
Author(s):  
Julia Haltiwanger Nicodemus ◽  
Xiaoqi Huang ◽  
Emily Dentinger ◽  
Kyle Petitt ◽  
Joshua H. Smith

Abstract In this work, we investigate the effects of the width of an annular baffle region on natural convection heat transfer to an immersed, coiled heat exchanger in an otherwise quiescent sensible hot water storage tank. In the experiments, the coiled heat exchanger sits in an annular region created by the tank wall and a straight, cylindrical baffle. The width of this baffle region is 1.5, 2, 3, or 4 times the heat exchanger diameter. These experiments are compared to each other and to corresponding control experiments with no baffle. In general, all baffles create considerable benefits over their respective control experiments, consistent with past studies. The considered metrics of heat transfer rate, fraction of energy discharged from the tank, heat exchanger outlet temperature, and heat exchanger effectiveness show that heat transfer is improved slightly by narrowing the baffle region. For example, relative to their respective controls, the energy extracted from the tank after 30 min of discharge in the 1.5D, 2D, 3D, and 4D experiments is 23.3%, 20.8%, 18.1%, and 14.6% higher, respectively. This improvement in natural convection heat transfer as the baffle region narrows is attributed to the increasing thermal stratification observed with increasingly narrow baffle regions.


2018 ◽  
Vol 6 (3) ◽  
pp. 1-12
Author(s):  
Kamil Abdul Hussien

Abstract-The present work investigates the enhancement of heat transfer by using different number of circular fins (8, 10, 12, 16, and 20) in double tube counter flow heat exchanger experimentally. The fins are made of copper with dimensions 66 mm OD, 22 mm ID and 1 mm thickness. Each fin has three of 14 mm diameter perforations located at 120o from each to another. The fins are fixed on a straight smooth copper tube of 1 m length, 19.9 mm ID and 22.2 mm OD. The tube is inserted inside the insulated PVC tube of 100 mm ID. The cold water is pumped around the finned copper tube, inside the PVC, at mass flow rates range (0.01019 - 0.0219) kg/s. The Reynold's number of hot water ranges (640 - 1921). The experiment results are obtained using six double tube heat exchanger (1 smooth tube and the other 5 are finned one). The results, illustrated that the heat transfer coefficient proportionally with the number of fin. The results also showed that the enhancement ratio of heat transfer for finned tube is higher than for smooth tube with (9.2, 10.2, 11.1, 12.1 13.1) times for number of fins (8, 10, 12, 16 and 20) respectively.


Nanomaterials ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 1656 ◽  
Author(s):  
Mehdi Ghalambaz ◽  
Hossein Arasteh ◽  
Ramin Mashayekhi ◽  
Amir Keshmiri ◽  
Pouyan Talebizadehsardari ◽  
...  

This study investigated the laminar convective heat transfer and fluid flow of Al2O3 nanofluid in a counter flow double-pipe heat exchanger equipped with overlapped twisted tape inserts in both inner and outer tubes. Two models of the same (co-swirling twisted tapes) and opposite (counter-swirling twisted tapes) angular directions for the stationary twisted tapes were considered. The computational fluid dynamic simulations were conducted through varying the design parameters, including the angular direction of twisted tape inserts, nanofluid volume concentration, and Reynolds number. It was found that inserting the overlapped twisted tapes in the heat exchanger significantly increases the thermal performance as well as the friction factor compared with the plain heat exchanger. The results indicate that models of co-swirling twisted tapes and counter-swirling twisted tapes increase the average Nusselt number by almost 35.2–66.2% and 42.1–68.7% over the Reynolds number ranging 250–1000, respectively. To assess the interplay between heat transfer enhancement and pressure loss penalty, the dimensionless number of performance evaluation criterion was calculated for all the captured configurations. Ultimately, the highest value of performance evaluation criterion is equal to 1.40 and 1.26 at inner and outer tubes at the Reynolds number of 1000 and the volume fraction of 3% in the case of counter-swirling twisted tapes model.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 716
Author(s):  
Saulius Pakalka ◽  
Kęstutis Valančius ◽  
Giedrė Streckienė

Latent heat thermal energy storage systems allow storing large amounts of energy in relatively small volumes. Phase change materials (PCMs) are used as a latent heat storage medium. However, low thermal conductivity of most PCMs results in long melting (charging) and solidification (discharging) processes. This study focuses on the PCM melting process in a fin-and-tube type copper heat exchanger. The aim of this study is to define analytically natural convection heat transfer coefficient and compare the results with experimental data. The study shows how the local heat transfer coefficient changes in different areas of the heat exchanger and how it is affected by the choice of characteristic length and boundary conditions. It has been determined that applying the calculation method of the natural convection occurring in the channel leads to results that are closer to the experiment. Using this method, the average values of the heat transfer coefficient (have) during the entire charging process was obtained 68 W/m2K, compared to the experimental result have = 61 W/m2K. This is beneficial in the predesign stage of PCM-based thermal energy storage units.


2021 ◽  
Vol 408 ◽  
pp. 119-128
Author(s):  
Md Yeashir Arafat ◽  
Shashwata Chakraborty

The thermophysical properties as well as the thermal performance of a nanofluid can be altered upon varying the nanoparticle type and/or nanoparticle volume concentration. Herein, the effects of variable nanoparticle concentration on water-based TiO2, SiO2, TiC, and SiC nanofluids have been studied analytically. The dispersion effects of 1-4% nanoparticle on the single-phase forced convection heat transfer performance of the nanofluids have been investigated. The effective thermophysical properties of the nanofluids are determined adopting the general correlations. The flow velocities of the nanofluids relative to their base fluids are assumed to be constant. Mouromtseff number has been employed as a convenient figure of merit to compare the nanofluids under fully developed internal laminar and turbulent flow conditions. The results indicate an increase in effective density, thermal conductivity, and dynamic viscosity of the nanofluids. Nanofluids containing carbide suspensions exhibit superior heat transfer properties compared to those having oxide suspensions.


Author(s):  
Chen-Ru Zhao ◽  
Zhen Zhang ◽  
Qian-Feng Liu ◽  
Han-Liang Bo ◽  
Pei-Xue Jiang

Numerical investigations are performed on the convection heat transfer of supercritical pressure fluid flowing through vertical mini tube with inner diameter of 0.27 mm and inlet Reynolds number of 1900 under various heat fluxes conditions using low Reynolds number k-ε turbulence models due to LB (Lam and Bremhorst), LS (Launder and Sharma) and V2F (v2-f). The predictions are compared with the corresponding experimentally measured values. The prediction ability of various low Reynolds number k-ε turbulence models under deteriorated heat transfer conditions induced by combinations of buoyancy and flow acceleration effects are evaluated. Results show that all the three models give fairly good predictions of local wall temperature variations in conditions with relatively high inlet Reynolds number. For cases with relatively low inlet Reynolds number, V2F model is able to capture the general trends of deteriorated heat transfer when the heat flux is relatively low. However, the LS and V2F models exaggerate the flow acceleration effect when the heat flux increases, while the LB model produces qualitative predictions, but further improvements are still needed for quantitative prediction. Based on the detailed flow and heat transfer information generated by simulation, a better understanding of the mechanism of heat transfer deterioration is obtained. Results show that the redistribution of flow field induced by the buoyancy and flow acceleration effects are main factors leading to the heat transfer deterioration.