Effect of Hydraulic Loading on Removal Efficiency of the Folds Stable Surface Flow Wetland

2011 ◽  
Vol 356-360 ◽  
pp. 1055-1060
Author(s):  
Cheng Duan Wang ◽  
Hai Xia Fu

Three folds stable surface flow wetlands (FSSFWs) were operated at different hydraulic loadings of 0.80, 0.53 and 0.27m3/ (m2•d) to treat the decentralized domestic sewage. And we investigated the effect of the hydraulic loading rate (HLR) on the removal efficiency of FSSFWs by measuring five indicators of chemical oxygen demand (COD), total nitrogen (TN), ammonium (NH3-N), total phosphorus (TP) and suspended substance (SS). The research results indicated that the hydraulic loading had great impact on the removal efficiency of FSSFWs, and was looked upon as one crucial factor for FSSFWs design. The removal efficiency of FSSFWs presented a downward trend in various degrees along with the increase of hydraulic loading. Also the hydraulic loading had greater influences on the removal rate of NH3-N and TN than COD, TP and SS. Considering the operation costs, the treatment capacity and the purification effect in this experiment, we could ensure the efficient and stable operation of FSSFWs with HLR at 0.53 m3/ (m2•d) and HRT at 0.4 m3•d-1, which were the most appropriate options.

2017 ◽  
Vol 77 (4) ◽  
pp. 988-998 ◽  
Author(s):  
Tadesse Alemu ◽  
Andualem Mekonnen ◽  
Seyoum Leta

Abstract In the present study, a pilot scale horizontal subsurface flow constructed wetland (CW) system planted with Phragmites karka; longitudinal profile was studied. The wetland was fed with tannery wastewater, pretreated in a two-stage anaerobic digester followed by a sequence batch reactor. Samples from each CW were taken and analyzed using standard methods. The removal efficiency of the CW system in terms of biological oxygen demand (BOD), chemical oxygen demand (COD), Cr and total coliforms were 91.3%, 90%, 97.3% and 99%, respectively. The removal efficiency for TN, NO3− and NH4+-N were 77.7%, 66.3% and 67.7%, respectively. Similarly, the removal efficiency of SO42−, S2− and total suspended solids (TSS) were 71.8%, 88.7% and 81.2%, respectively. The concentration of COD, BOD, TN, NO3−N, NH4+-N, SO42 and S2− in the final treated effluent were 113.2 ± 52, 56 ± 18, 49.3 ± 13, 22.75 ± 20, 17.1 ± 6.75, 88 ± 120 and 0.4 ± 0.44 mg/L, respectively. Pollutants removal was decreased in the first 12 m and increased along the CW cells. P. karka development in the first cell of CW was poor, small in size and experiencing chlorosis, but clogging was higher in this area due to high organic matter settling, causing a partial surface flow. The performance of the pilot CW as a tertiary treatment showed that the effluent meets the permissible discharge standards.


2004 ◽  
Vol 49 (5-6) ◽  
pp. 281-288 ◽  
Author(s):  
S.J. Kim ◽  
P.Y. Yang

A two-stage entrapped mixed microbial cell (2SEMMC) process which separates nitrification and denitrification phases by the installation of the anoxic and oxic EMMC reactors packed with EMMC carriers was operated with 6, 4, 3, and 2 hours of hydraulic retention time (HRT) using simulated domestic wastewater. The activated sludge was immobilized using cellulose acetate for the EMMC carriers. Similar soluble chemical oxygen demand (SCOD) removal efficiencies of 90-97% were observed for all HRTs (SCOD loading rate of 0.84-2.30 g/L/d) applied. In order to achieve more than 80 % of TN removal efficiency, the HRT should be maintained higher than 4 hours (less than 0.24 g/L/d of TN loading rate). Denitrification was a rate-limiting step which controlled overall TN removal efficiency at TN loading rate of 0.15-0.31 g/L/d although nitrification efficiencies achieved 97-99 %. The effluent TSS of less than 25 mg/L in the 2SEMMC process was maintained at the SCOD loading rate of less than 1.23 g/L/d with back-washing intervals of 5 and 10 days in the anoxic and oxic EMMC reactors, respectively. The minimum HRT of 4 hours is required for high removal efficiencies of organics (average 95.6 %) and nitrogen (average 80.5 %) in the 2SEMMC process with 3 times of recirculation ratio.


2016 ◽  
Vol 74 (7) ◽  
pp. 1509-1517 ◽  
Author(s):  
Linan Zhu ◽  
Hailing He ◽  
Chunli Wang

The hybrid membrane bioreactor (HMBR) has been applied in ship domestic sewage treatment under high volumetric loading for ship space saving. The mechanism and influence factors on the efficiency, including hydraulic retention time (HRT), dissolved oxygen (DO) of chemical oxygen demand (COD) removal were investigated. The HMBR's average COD removal rate was up to 95.13% on volumetric loading of 2.4 kgCOD/(m3•d) and the COD concentration in the effluent was 48.5 mg/L, far below the International Maritime Organization (IMO) discharge standard of 125 mg/L. DO had a more remarkable effect on the COD removal efficiency than HRT. In addition, HMBR revealed an excellent capability of resisting organics loading impact. Within the range of volumetric loading of 0.72 to 4.8 kg COD/(m3•d), the effluent COD concentration satisfied the discharge requirement of IMO. It was found that the organics degradation in the aeration tank followed the first-order reaction, with obtained kinetic parameters of vmax (2.79 d−1) and Ks (395 mg/L). The original finding of this study had shown the effectiveness of HMBR in organic contaminant degradation at high substrate concentration, which can be used as guidance in the full scale of the design, operation and maintenance of ship domestic sewage treatment devices.


2008 ◽  
Vol 57 (7) ◽  
pp. 1047-1052 ◽  
Author(s):  
U. Durán ◽  
O. Monroy ◽  
J. Gómez ◽  
F. Ramírez

The biological elimination of polymeric resins compounds (PRC) such as acrylic acid and their esters, vinyl acetate and styrene under methanogenic and oxygen-limited methanogenesis conditions was evaluated. Two UASB reactors (A and B) were used and the removal of the organic matter was studied in four stages. Reactor A was used as methanogenic control during the study. Initially both reactors were operated under methanogenic conditions. From the second stage reactor B was fed with 0.6 and 1 mg/L·d of oxygen (O2). Reactor A had diminution in chemical oxygen demand (COD) removal efficiency from 75±4% to 37±5%, by the increase of PRC loading rate from 750 to 1125 mg COD/L·d. In this reactor there was no styrene elimination. In reactor B the COD removal efficiency was between 73±5% and 80±2%, even with the addition of O2 and increase of the PRC loading rate, owing to oxygen being used in the partial oxidation of these compounds. In this reactor the yields were modified from 0.56 to 0.40 for CH4 and from 0.31 to 0.60 for CO2. The O2 in low concentrations increased 40.7% the consumption rates of acrylic acid, methyl acrylate and vinyl acetate, allowing styrene consumption with a rate of 0.103 g/L·d. Batch cultures demonstrated that under methanogenic and oxygen-limited methanogenesis conditions, the glucose was not used as an electron acceptor in the elimination of PRC.


2013 ◽  
Vol 864-867 ◽  
pp. 1498-1502
Author(s):  
Qing Feng Chen ◽  
Wen Guo Dong ◽  
Jun Jian Ma ◽  
Qing Li ◽  
Xin Guo Gao ◽  
...  

Hydraulic loading rate (HLR) is an important operational parameter for constructed wetland to purify wastewater. In this paper, it is the main objective to select the optimal parameter of HLR. During the four HLRs (i.e., 6 cm/d, 12 cm/d, 24 cm/d and 48 cm/d) operation period, six days were used as one stage. The experimental results showed that the best average removal rates of CODcr (59.7%) and NH3-N (89.4%) were at the HLR of 6 cm/d. In the meantime, the best average removal rate of total phosphorus (TP, 50.0%) was at the HLR of 24 cm/d. According to the low influent TP concentration, it is suggested that the HLR of 6 cm/d should be used in the multi-stage constructed wetland.


2012 ◽  
Vol 610-613 ◽  
pp. 331-336
Author(s):  
Yuan Hua Xie ◽  
Tong Zhu ◽  
Xiao Jiang Liu ◽  
Hui Liu ◽  
Jin Han

An anoxic-oxic activated sludge process (AOASP) was carried out to degrade nonylphenol polyethoxylates (NPEOs). The carbon source in influent was replaced stepwise by a mixture of nonylphenol decaethoxylate (M-NP10EO). The 2nd-derivative UV-spectrometry was applied to determine the total amount of M-NP10EO in water samples. Chemical oxygen demand (COD) removal efficiency achieves about 85% under the highest M-NP10EO loading rate, and M-NP10EO removal efficiency is about 80%. Denaturing gradient gel electrophoresis (DGGE) results of activated sludges show that the microbe species decrease but gradually stabilize with the increase of M-NP10EO concentration in influent. Fluorescence in situ hybridization (FISH) results of activated sludges showe that the dominant microflora under the highest M-NP10EO loading rate is β-Proteobacteria (35%), followed by α-Proteobacteria (15%), γ-Proteobacteria (5%) and Actinobateria (4%).


2016 ◽  
Vol 107 ◽  
pp. 102-112 ◽  
Author(s):  
Philani Ncube ◽  
Marc Pidou ◽  
Tom Stephenson ◽  
Bruce Jefferson ◽  
Peter Jarvis

2013 ◽  
Vol 67 (3) ◽  
pp. 587-593 ◽  
Author(s):  
L. Yerushalmi ◽  
M. Alimahmoodi ◽  
C. N. Mulligan

Simultaneous removal of carbon, nitrogen and phosphorus was examined along with reduced generation of biological sludge during the treatment of synthetic wastewater and hog waste by the BioCAST technology. This new multi-environment wastewater treatment technology contains both suspended and immobilized microorganisms, and benefits from the presence of aerobic, microaerophilic, anoxic and anaerobic conditions for the biological treatment of wastewater. The influent concentrations during the treatment of synthetic wastewater were 1,300–4,000 mg chemical oxygen demand (COD)/L, 42–115 mg total nitrogen (TN)/L, and 19–40 mg total phosphorus (TP)/L. The removal efficiencies reached 98.9, 98.3 and 94.1%, respectively, for carbon, TN and TP during 225 days of operation. The removal efficiencies of carbon and nitrogen showed a minimal dependence on the nitrogen-to-phosphorus (N/P) ratio, while the phosphorus removal efficiency showed a remarkable dependence on this parameter, increasing from 45 to 94.1% upon the increase of N/P ratio from 3 to 4.5. The increase of TN loading rate had a minimal impact on COD removal rate which remained around 1.7 kg/m3 d, while it contributed to increased TP removal efficiency. The treatment of hog waste with influent COD, TN and TP concentrations of 960–2,400, 143–235 and 25–57 mg/L, respectively, produced removal efficiencies up to 89.2, 69.2 and 47.6% for the three contaminants, despite the inhibitory effects of this waste towards biological activity. The treatment system produced low biomass yields with average values of 3.7 and 8.2% during the treatment of synthetic wastewater and hog waste, respectively.


2015 ◽  
Vol 71 (6) ◽  
pp. 832-839 ◽  
Author(s):  
O. Tiron ◽  
C. Bumbac ◽  
I. V. Patroescu ◽  
V. R. Badescu ◽  
C. Postolache

The study used activated algae granules for low-strength wastewater treatment in sequential batch mode. Each treatment cycle was conducted within 24 h in a bioreactor exposed to 235 μmol/m2/s light intensity. Wastewater treatment was performed mostly in aerobic conditions, oxygen being provided by microalgae. High removal efficiency of chemical oxygen demand (COD) was achieved (86–98%) in the first hours of the reaction phase, during which the indicator's removal rate was 17.4 ± 3.9 mg O2/g h; NH4+ was removed during organic matter degradation processes with a rate of 1.8 ± 0.6 mg/g h. After almost complete COD removal, the NH4+ remaining in the liquor was removed through nitrification processes promoted by the increase of the liquor's oxygen saturation (O2%), the transformation rate of NH4+ into NO3− increasing from 0.14 ± 0.05 to 1.5 ± 0.4 mg NH4+/g h, along with an O2% increase. A wide removal efficiency was achieved in the case of PO43– (11–85%), with the indicator's removal rate being 1.3 ± 0.7 mg/g h. In the provided optimum conditions, the occurrence of the denitrifying activity was also noticed. A large pH variation was registered (5–8.5) during treatment cycles. The granular activated algae system proved to be a promising alternative for wastewater treatment as it also sustains cost-efficient microalgae harvesting, with microalgae recovery efficiency ranging between 99.85 and 99.99% after granules settling with a velocity of 19 ± 3.6 m/h.


Water ◽  
2020 ◽  
Vol 12 (4) ◽  
pp. 1054 ◽  
Author(s):  
Xueyuan Bai ◽  
Xianfang Zhu ◽  
Haibo Jiang ◽  
Zhongqiang Wang ◽  
Chunguang He ◽  
...  

Constructed wetlands can play an active role in improving the water quality of urban rivers. In this study, a sequential series system of the floating-bed constructed wetland (FBCW), horizontal subsurface flow constructed wetland (HSFCW), and surface flow constructed wetland (SFCW) were constructed for the urban river treatment in the cold regions of North China, which gave full play to the combined advantages. In the Yitong River, the designed capacity and the hydraulic loading of the system was 100 m3/d and 0.10 m3/m2d, respectively. The hydraulic retention time was approximately 72 h. The monitoring results, from April to October in 2016, showed the multiple wetland ecosystem could effectively remove chemical oxygen demand (COD), ammonia nitrogen (NH4+-N), total nitrogen (TN), total phosphate (TP), and suspended solids (SS) at average removal rates of 74.79%, 80.90%, 71.12%, 78.44%, and 91.90%, respectively. The removal rate of SS in floating-bed wetland was the largest among all the indicators (80.24%), which could prevent the block of sub-surface flow wetland effectively. The sub-surface flow wetland could remove the NH4-N, TN, and TP effectively, and the contribution rates were 79.20%, 64.64%, and 81.71%, respectively. The surface flow wetland could further purify the TN and the removal rate of TN could reach 23%. The total investment of this ecological engineering was $12,000. The construction cost and the operation cost were $120 and $0.02 per ton of polluted water, which was about 1/3 to 1/5 and 1/6 to 1/3 of the conventional sewage treatment, respectively. The results of this study provide a technical demonstration of the restoration of polluted water in urban rivers in northern China.


Sign in / Sign up

Export Citation Format

Share Document