Carbo-Nitride Coating Treatment of Titanium by a Diffusional Method

2007 ◽  
Vol 280-283 ◽  
pp. 1847-1850
Author(s):  
Kiyotaka Matsuura ◽  
Masayuki Kudoh

Titanium surface was covered with thin layers of titanium monocarbo-nitride, Ti(C,N) and nitrogen-rich a-titanium, after a titanium specimen was heat-treated at a temperature between 1388 and 1573 K in a graphite cup in an atmosphere of pure nitrogen. The total thickness of those layers increased in accordance with the parabolic law when both temperature and time of the heat treatment increased. The parabolic rate constants was described as k = 4.83 × 10-6 exp (-178000/RT)m2/s using Arrhenius’ equation. Vickers hardness of the Ti(C, N) layer remained at approximately 2000 but that of the a-titanium layer gradually decreased from 1500 to 500, as the distance from the surface increased. The carbo-nitridetreated titanium exhibited excellent resistances in wear and corrosion compared with those of pure titanium.

2020 ◽  
Vol 985 ◽  
pp. 64-68
Author(s):  
Kenta Nisogi ◽  
Satoshi Okano ◽  
Sengo Kobayashi ◽  
Kensuke Kuroda ◽  
Takeaki Okamoto

Surface wettability is thought to influence the osteoconductivity of bone-substituting materials; however, the effects of surface wettability on osteoblast behavior are not well understood. In this study, we prepared both an as-polished pure titanium with a water contact angle (WCA) of 57° and heat-treated pure titanium with more hydrophobic surface and WCAs of 68°-98°. The effects of the surface wettability of pure titanium on osteoblast behaviors were evaluated by in vitro assays. Compared with the as-polished titanium, the proliferation rate of osteoblast increased on heat-treated titanium. This suggested that surface wettability affects osteoblast behaviors, meaning osteoconductivity is influenced by surface wettability.


Author(s):  
S.J. Splinter ◽  
J. Bruley ◽  
P.E. Batson ◽  
D.A. Smith ◽  
R. Rosenberg

It has long been known that the addition of Cu to Al interconnects improves the resistance to electromigration failure. It is generally accepted that this improvement is the result of Cu segregation to Al grain boundaries. The exact mechanism by which segregated Cu increases service lifetime is not understood, although it has been suggested that the formation of thin layers of θ-CuA12 (or some metastable substoichiometric precursor, θ’ or θ”) at the boundaries may be necessary. This paper reports measurements of the local electronic structure of Cu atoms segregated to Al grain boundaries using spatially resolved EELS in a UHV STEM. It is shown that segregated Cu exists in a chemical environment similar to that of Cu atoms in bulk θ-phase precipitates.Films of 100 nm thickness and nominal composition Al-2.5wt%Cu were deposited by sputtering from alloy targets onto NaCl substrates. The samples were solution heat treated at 748K for 30 min and aged at 523K for 4 h to promote equilibrium grain boundary segregation. EELS measurements were made using a Gatan 666 PEELS spectrometer interfaced to a VG HB501 STEM operating at 100 keV. The probe size was estimated to be 1 nm FWHM. Grain boundaries with the narrowest projected width were chosen for analysis. EDX measurements of Cu segregation were made using a VG HB603 STEM.


Nanomaterials ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3306
Author(s):  
Yuzhu He ◽  
Yuanyuan Li ◽  
Enjun Zuo ◽  
Songling Chai ◽  
Xiang Ren ◽  
...  

For the benefit of antibacterial Ti on orthopedic and dental implants, a bioactive coating (Pac@PLGA MS/HA coated Ti) was deposited on the surface of pure titanium (Ti), which included two layers: an acid–alkali heat pretreated biomimetic mineralization layer and an electrosprayed Poly (D,L-lactide-co- glycolic acid) (PLGA) microsphere layer as a sustained-release system. Hydroxyapatite (HA) in mineralization layer was primarily prepared on the Ti followed by the antibacterial coating of Pac-525 loaded by PLGA microspheres. After observing the antimicrobial peptides distributed uniformly on the titanium surface, the release assay showed that the release of Pac-525 from Pac@PLGA MS/HA coated Ti provided a large initial burst followed by a slow release at a flat rate. Pac@PLGA MS/HA coated Ti exhibited a strong cytotoxicity to both Gram-negative bacteria (Escherichia coli) and Gram-positive bacteria (Staphylococcus aureus). In addition, Pac@PLGA MS/HA coated Ti did not affect the growth and adhesion of the osteoblast-like cell line, MC3T3-E1. These data suggested that a bionic mineralized composite coating with long-term antimicrobial activity was successfully prepared.


2013 ◽  
Vol 49 ◽  
pp. 1042-1047 ◽  
Author(s):  
Qiong Wang ◽  
Ping-Ze Zhang ◽  
Dong-Bo Wei ◽  
Ruo-Nan Wang ◽  
Xiao-Hu Chen ◽  
...  

2014 ◽  
Vol 8 (1) ◽  
pp. 114-119 ◽  
Author(s):  
In-Sung Yeo

Screw-shaped endosseous implants that have a turned surface of commercially pure titanium have a disadvantage of requiring a long time for osseointegration while those implants have shown long-term clinical success in single and multiple restorations. Titanium implant surfaces have been modified in various ways to improve biocompatibility and accelerate osseointegration, which results in a shorter edentulous period for a patient. This article reviewed some important modified titanium surfaces, exploring the in vitro, in vivo and clinical results that numerous comparison studies reported. Several methods are widely used to modify the topography or chemistry of titanium surface, including blasting, acid etching, anodic oxidation, fluoride treatment, and calcium phosphate coating. Such modified surfaces demonstrate faster and stronger osseointegration than the turned commercially pure titanium surface. However, there have been many studies finding no significant differences in in vivo bone responses among the modified surfaces. Considering those in vivo results, physical properties like roughening by sandblasting and acid etching may be major contributors to favorable bone response in biological environments over chemical properties obtained from various modifications including fluoride treatment and calcium phosphate application. Recently, hydrophilic properties added to the roughened surfaces or some osteogenic peptides coated on the surfaces have shown higher biocompatibility and have induced faster osseointegration, compared to the existing modified surfaces. However, the long-term clinical studies about those innovative surfaces are still lacking.


2010 ◽  
Vol 638-642 ◽  
pp. 846-851 ◽  
Author(s):  
Abdoul Fatah Kanta ◽  
Véronique Vitry ◽  
Fabienne Delaunois

Nickel-boron coatings were synthesized on mild steel by the electroless deposition method. Some of the coatings were submitted to a hardening heat treatment at 400°C during 1 hour in an atmosphere containing 95% Ar and 5% H2. Uncoated steel, treated and untreated samples were submitted to the Taber abrasion test to assess their wear resistance. The wear track was then examined by SEM and roughness measurement. The Taber Wear Index of untreated samples was slightly better than that of steel but heat treated samples attained TWI as small as 13. The corrosion resistance of the samples was investigated by the way of polarization and electrochemical impedance spectroscopy (EIS) and the influence of the heat treatment was observed.


2018 ◽  
Vol 5 (2) ◽  
pp. 7571-7576 ◽  
Author(s):  
M. Krishna Kumar ◽  
R. Saravanan ◽  
R. Sellamuthu ◽  
Vijay Narayanan

2012 ◽  
Vol 23 (5) ◽  
pp. 496-501 ◽  
Author(s):  
Marcelo Bighetti Toniollo ◽  
Rodrigo Galo ◽  
Ana Paula Macedo ◽  
Renata Cristina Silveira Rodrigues ◽  
Ricardo Faria Ribeiro ◽  
...  

The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways. The treatments resulted in the following groups: GA (control): immersion in distilled water; GB: immersion in 0.05% NaF for 3 min daily; GC: immersion in 0.2% NaF for 3 min daily; GD: immersion in 0.05% NaF for 3 min every 2 weeks; and GE: immersion in 0.2% NaF for 3 min every 2 weeks. The experiment lasted 60 days. Roughness was measured initially and every 15 days subsequently up to 60 days. After 60 days, corrosion analysis and anodic polarization were done. The samples were examined by scanning electron microscopy (SEM). The roughness data were analyzed by ANOVA and there was no significant difference among groups and among time intervals. The corrosion data (i corr) were analyzed by the Mann-Whitney test, and significant differences were found between GA and GC, GB and GC, GC and GD, GC and GE. SEM micrographs showed that the titanium surface exposed to NaF presented corrosion that varied with the different concentrations. This study suggests that the use of 0.05% NaF solution on cpTi is safe, whereas the 0.2% NaF solution should be carefully evaluated with regard to its daily use.


Sign in / Sign up