Numerical Investigations on Behavior of Strengthened RC Beams with CFRP under Combined Bending and Torsion

2020 ◽  
Vol 857 ◽  
pp. 120-129
Author(s):  
Abdul Muttalib I. Said ◽  
Qais H. Al-Shemmari

The numerical investigations were carried out to study the behavior of reinforced concrete beams strengthened by CFRP under different loading conditions (pure bending and combined bending and torsion). The numerical work included analysis of eight experimentally tested beams of rectangular cross-section dimensions of (160×240) mm and (2600) mm length keeping the area of the ordinary reinforcement constant for all beams. The following parameters were taken into consideration, twisting to bending moment ratio (T/M) and CFRP strengthening arrangement. The analyzed beams are divided into four groups. Each group consists of two beams; the first beam is without CFRP strengthening, the other beam is strengthened with CFRP. Each beam is loaded to a different loading conditions (pure bending, T/M=0.5, T/M=1.0, T/M=2.0). The CFRP sheets were attached externally to the beam. Analysis results were analyzed based on influence of CFRP on ultimate load and vertical mid-span deflection. According to the numerical study, it was found that all strengthening arrangements of CFRP sheets exhibited a significant increase in ultimate strength. The three-dimensional (3D) finite element model (FEM) utilized in present work is capable to simulate the behavior of externally strengthened reinforced concrete beams by CFRP. Full bond connections (no slip) are assumed between the CFRP sheets and surface of concrete. The comparison between the numerical and the experimental results declared the validity of the numerical analysis where the range of the (Pexp./PANSYS) ratio in ultimate load was from 0.847 to 1.157. The general behavior of the (FEM) shows good agreement with the test results from the experimentally tested beams.

2020 ◽  
Vol 857 ◽  
pp. 109-119
Author(s):  
Abdul Muttalib I. Said ◽  
Qais H. Al-Shemmari

The experimental investigations were carried out to study the behavior of reinforced concrete beams strengthened by CFRP sheets under different loading conditions (pure bending, combined bending and torsion and pure torsion). The experimental work included testing twenty RC beams of the rectangular cross-section of dimensions of 160×240 mm and of 2600 mm length with an area of the ordinary reinforcement being kept constant for all beams. Two parameters were taken into consideration (Twisting to bending moment ratio (T/M) and CFRP strengthening pattern). The tested beams are divided into five groups. Each group consists of four beams; the first beam is without CFRP strengthening, the other three are strengthened with CFRP sheets of different arrangements (U-stirrups, U-stirrups and longitudinal CFRP sheets in the bottom and Full U- stirrups wrapping). Each beam is loaded to a different loading conditions (pure bending, T/M = 0.5, T/M = 1.0, T/M = 2.0 and pure torsion). The CFRP sheets were attached externally to the beam. Test results were analyzed based on the influence of CFRP on the ultimate load, vertical mid-span deflection and failure modes. In the experimental work, it was found that all strengthening patterns of CFRP sheets exhibited a significant increase in ultimate strength. This increase reached up to 78.9% for tested beams, when the beam strengthened in the form of full U- stirrups wrapping pattern for T/M = 0.5. In this study, it is observed that the use of external CFRP sheets attached to the tension sides of beams (U-stirrups and longitudinal CFRP in the bottom) could enhance the ultimate load capacity by 32.7% over the capacity of the unstrengthen control beam for T/M = 1.0.


2020 ◽  
Vol 38 (5A) ◽  
pp. 669-680
Author(s):  
Ghazwan K. Mohammed ◽  
Kaiss F. Sarsam ◽  
Ikbal N. Gorgis

The study deals with the effect of using Slurry infiltrated fiber concrete (SIFCON) with the reinforced concrete beams to explore its enhancement to the flexural capacity. The experimental work consists of the casting of six beams, two beams were fully cast by conventional concrete (CC) and SIFCON, as references. While the remaining was made by contributing a layer of SIFCON diverse in-depth and position, towards complete the overall depths of the built-up beam with conventional concrete CC. Also, an investigation was done through the control specimens testing about the mechanical properties of SIFCON. The results showed a stiffer behavior with a significant increase in load-carrying capacity when SIFCON used in tension zones. Otherwise high ductility and energy dissipation appeared when SIFCON placed in compression zones with a slight increment in ultimate load. The high volumetric ratio of steel fibers enabled SIFCON to magnificent tensile properties.


2012 ◽  
Vol 535-537 ◽  
pp. 1803-1806
Author(s):  
Shun Bo Zhao ◽  
Peng Bing Hou ◽  
Fu Lai Qu

An experimental study was carried out to examine the non-uniform corrosion of plain steel bars in reinforced concrete beams partially placed in 5% sodium chloride solution under conditions of accelerated corrosion. 4 reinforced concrete beams with different concrete strength were made. The crack distributions of the beams due to pre-loads and expansion of corrosion product, and the sectional corrosion characteristics of plain steel bars are described in detail. The sectional area loss relating to mass loss and change along pure bending length of the beams are discussed. These can be used as the basis of test for further studies to build the numerical models of serviceability of corroded reinforced concrete beams.


2014 ◽  
Vol 7 (5) ◽  
pp. 723-746 ◽  
Author(s):  
D. M. Santos ◽  
F. R. Stucchi ◽  
A. T. Beck

This paper presents an investigation on the safety of structural elements submitted to pure bending, produced in reinforced concrete, in steel and steel-concrete composites, and designed according to Brazilian codes NBR8681:2003, NBR6118:2007 and NBR8800:2008. The study allows a comparison of the relative safety of beams produced with these materials and designed using these codes. Comparative studies between the performances of different materials are difficult to find in the published literature. The present study shows that reliability indexes for reinforced concrete beams are satisfactory; however, results for steel beams are below limit values established in international design standards. Reliability indexes found herein for steel-concrete composite beams are intermediate to concrete and steel beams.


2011 ◽  
Vol 243-249 ◽  
pp. 929-933
Author(s):  
Na Ha ◽  
Lian Guang Wang ◽  
Shen Yuan Fu

In order to improve the bearing capacity of SRC which is related with deformation and stiffiness, SRC beams should be strengthened by CFRP. Based on the experiment of six pre-splitting steel reinforced concrete beams strengthened with (Prestressed) CFRP sheets, the deformation of beams are discussed. Load-deformation curves are obtained by the experiment. Considering the influence of intial bending moment on SRC beams, the calculated deformation formulas of SRC beams strengthened by (Prestressed) CFRP are deduced. The results showed that the load-deformation curves of normal and strengthened beams respectively showed three and two linear characteristics. The theoretical results which calculated by the formulas of deformation are well agreement with the experimental results.


2019 ◽  
Vol 3 (2) ◽  
pp. 135
Author(s):  
Novita Ike Triyuliani ◽  
Sri Murni Dewi ◽  
Lilya Susanti

The innovations strengthening building structures are important topics. Failure in structures such as beams and columns due to time, re-functions of a building, even initial design errors that are weak or lack the safety factor of a building structure. External reinforced concrete beams are one of the beams currently being developed. It is a concrete block with reinforcement of steel reinforcement on the outer (external) of the beam. This study aims to determine the index of increasing beam strength and ductility after retrofitting external steel reinforcement, which has the dimension of beams 15 x 15 x 100 cm, repeating 12 pcs, with external reinforcement each 6 pcs 2Ø6 and 3Ø6. The results from this study are an increasing the index of beam flexural strength after retrofit with external steel reinforcement. Meanwhile, beams after retrofit with 2Ø6 external steel have an average increase index of 1.25 and 1.21 while for external steel 3Ø6 are 1.29 and 1.60 respectively. The ductility depends on the value of ultimate load and maximum deflection that occurs, where the ductility value for the comparison of each specimen experiences a reduction in the average ductility value with 2Ø6 external steel which is 37.74% and 70.95% while with 3Ø6 external steel is 61,65% and 60.62%. Berbagai inovasi upaya peningkatan kekuatan struktur bangunan telah menjadi bahasan yang penting. Kegagalan pada struktur seperti balok dan kolom karena umur, alih fungsi suatu bangunan, bahkan kesalahan desain awal yang lemah atau kurang memenuhi faktor keamanan suatu struktur bangunan. Balok beton bertulangan eksternal adalah salah satu balok yang sedang dikembangkan pada saat ini, yaitu balok beton dengan perkuatan tulangan baja di sisi terluar (eksternal). Penelitian ini bertujuan untuk mengetahui indeks peningkatan kekuatan balok dan daktilitas setelah dilakukan perbaikan menggunakan tulangan baja eksternal, dengan dimensi balok 15 × 15 × 100 cm berulang 12 buah, penambahan tulangan baja eksternal masingmasing 6 buah 2Ø6 dan 3Ø6. Hasil yang didapat dari penelitian ini adalah indeks peningkatan kekuatan lentur balok setelah dilakukan perbaikan menggunakan tulangan baja eksternal. Dimana balok setelah dilakukan perbaikan dengan baja eksternal 2Ø6 memiliki indeks peningkatan rata-rata 1,25 dan 1,21 sedangkan untuk baja eksternal 3Ø6 masing-masing 1,29 dan 1,60. Daktilitas tergantung dari nilai beban ultimit dan lendutan maksimum yang terjadi, dimana nilai daktilitas untuk perbandingan tiap benda uji mengalami reduksi nilai daktilitas rata-rata dengan baja eksternal 2Ø6 yaitu sebesar 37,74% dan 70,95% sedangkan dengan baja eksternal 3Ø6 sebesar 61,65% dan 60,62%.


Author(s):  
Eswari Natarajan

Abstract: The effect of fibre content on the Strength and ductility behaviour of hybrid fibre reinforced concrete (HFRC) beams having different fibre volume fractions was investigated. The parameters of this investigation included service load, ultimate load, service load deflection, ultimate load deflection, crack width, deflection ductility and energy ductility. The fibre volume fraction (Vf) ranged from 0.0 to 2.0 percent. Steel and polyolefin fibres were combined in different proportions and their impact on the above parameters was studied. The ductile response of hybrid fibre reinforced concrete beams was compared with that of control beam. The test results show that addition of 2.0 percent by volume of hybrid fibres improve the strength and ductility appreciably. Empirical expressions for predicting the strength and ductility of hybrid fibre reinforced concrete (HFRC) are proposed based on regression analysis. A close agreement has been obtained between the predicted and experimental results.


2020 ◽  
Vol 857 ◽  
pp. 162-168
Author(s):  
Haidar Abdul Wahid Khalaf ◽  
Amer Farouk Izzet

The present investigation focuses on the response of simply supported reinforced concrete rectangular-section beams with multiple openings of different sizes, numbers, and geometrical configurations. The advantages of the reinforcement concrete beams with multiple opening are mainly, practical benefit including decreasing the floor heights due to passage of the utilities through the beam rather than the passage beneath it, and constructional benefit that includes the reduction of the self-weight of structure resulting due to the reduction of the dead load that achieves economic design. To optimize beam self-weight with its ultimate resistance capacity, ten reinforced concrete beams having a length, width, and depth of 2700, 100, and 400 mm, respectively were fabricated and tested as simply supported beams under one incremental concentrated load at mid-span until failure. The design parameters were the configuration and size of openings. Three main groups categorized experimental beams comprise the same area of openings and steel reinforcement details but differ in configurations. Three different shapes of openings were considered, mainly, rectangular, parallelogram, and circular. The experimental results indicate that, the beams with circular openings more efficient than the other configurations in ultimate load capacity and beams stiffness whereas, the beams with parallelogram openings were better than the beams with rectangular openings. Commonly, it was observed that the reduction in ultimate load capacity, for beams of group I, II, and III compared to the reference solid beam ranged between (75 to 93%), (65 to 93%), and (70 to 79%) respectively.


Sign in / Sign up

Export Citation Format

Share Document