scholarly journals Comparing visual acuity in preschool children using the Lea symbols and Sheridan Gardiner charts

2015 ◽  
Vol 74 (1) ◽  
Author(s):  
Aghafekokhian B. Osaiyuwu ◽  
George N. Atuanya

Visual acuity measurement is a vital part of an optometric examination. The purpose of the present study was to compare visual acuity in preschool children using two charts – the Lea symbols chart and the Sheridan Gardiner chart. One hundred and fifty-three preschool children (72 boys and 81 girls) between the ages of 3 and 5 years (mean age and standard deviation 4.23 ± 0.78 years) were recruited from five randomly selected nursery schools. Distance visual acuity was measured monocularly and binocularly after a pre-test was done. An interval of 5 minutes was allowed for testing with both charts. The ages and sexes of each child were documented. Results showed a statistical difference in visual acuities using both charts (p < 0.05). There was also a statistical difference in both charts regarding age. There was no significant gender difference between the results from each chart.

2021 ◽  
Vol 25 (6) ◽  
pp. 1-68
Author(s):  
Alexander C Day ◽  
Jennifer M Burr ◽  
Kate Bennett ◽  
Rachael Hunter ◽  
Catey Bunce ◽  
...  

Background Cataract surgery is one of the most common operations. Femtosecond laser-assisted cataract surgery (FLACS) is a technique that automates a number of operative steps. Objectives To compare FLACS with phacoemulsification cataract surgery (PCS). Design Multicentre, outcome-masked, randomised controlled non-inferiority trial. Setting Three collaborating NHS hospitals. Participants A total of 785 patients with age-related cataract in one or both eyes were randomised between May 2015 and September 2017. Intervention FLACS (n = 392 participants) or PCS (n = 393 participants). Main outcome measures The primary outcome was uncorrected distance visual acuity in the study eye after 3 months, expressed as the logarithm of the minimum angle of resolution (logMAR): 0.00 logMAR (or 6/6 if expressed in Snellen) is normal (good visual acuity). Secondary outcomes included corrected distance visual acuity, refractive outcomes (within 0.5 dioptre and 1.0 dioptre of target), safety and patient-reported outcome measures at 3 and 12 months, and resource use. All trial follow-ups were performed by optometrists who were masked to the trial intervention. Results A total of 353 (90%) participants allocated to the FLACS arm and 317 (81%) participants allocated to the PCS arm attended follow-up at 3 months. The mean uncorrected distance visual acuity was similar in both treatment arms [0.13 logMAR, standard deviation 0.23 logMAR, for FLACS, vs. 0.14 logMAR, standard deviation 0.27 logMAR, for PCS, with a difference of –0.01 logMAR (95% confidence interval –0.05 to 0.03 logMAR; p = 0.63)]. The mean corrected distance visual acuity values were again similar in both treatment arms (–0.01 logMAR, standard deviation 0.19 logMAR FLACS vs. 0.01 logMAR, standard deviation 0.21 logMAR PCS; p = 0.34). There were two posterior capsule tears in the PCS arm. There were no significant differences between the treatment arms for any secondary outcome at 3 months. At 12 months, the mean uncorrected distance visual acuity was 0.14 logMAR (standard deviation 0.22 logMAR) for FLACS and 0.17 logMAR (standard deviation 0.25 logMAR) for PCS, with a difference between the treatment arms of –0.03 logMAR (95% confidence interval –0.06 to 0.01 logMAR; p = 0.17). The mean corrected distance visual acuity was 0.003 logMAR (standard deviation 0.18 logMAR) for FLACS and 0.03 logMAR (standard deviation 0.23 logMAR) for PCS, with a difference of –0.03 logMAR (95% confidence interval –0.06 to 0.01 logMAR; p = 0.11). There were no significant differences between the arms for any other outcomes, with the exception of the mean binocular corrected distance visual acuity with a difference of –0.02 logMAR (95% confidence interval –0.05 to 0.00 logMAR) (p = 0.036), which favoured FLACS. There were no significant differences between the arms for any health, social care or societal costs. For the economic evaluation, the mean cost difference was £167.62 per patient higher for FLACS (95% of iterations between –£14.12 and £341.67) than for PCS. The mean QALY difference (FLACS minus PCS) was 0.001 (95% of iterations between –0.011 and 0.015), which equates to an incremental cost-effectiveness ratio (cost difference divided by QALY difference) of £167,620. Limitations Although the measurement of outcomes was carried out by optometrists who were masked to the treatment arm, the participants were not masked. Conclusions The evidence suggests that FLACS is not inferior to PCS in terms of vision after 3 months’ follow-up, and there were no significant differences in patient-reported health and safety outcomes after 12 months’ follow-up. In addition, the statistically significant difference in binocular corrected distance visual acuity was not clinically significant. FLACS is not cost-effective. Future work To explore the possible differences in vision in patients without ocular co-pathology. Trial registration Current Controlled Trials ISRCTN77602616. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 25, No. 6. See the NIHR Journals Library website for further project information. Moorfields Eye Charity (grant references GR000233 and GR000449 for the endothelial cell counter and femtosecond laser used).


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Cosimo Mazzotta ◽  
Frederik Raiskup ◽  
Farhad Hafezi ◽  
Emilio A Torres-Netto ◽  
Ashraf Armia Balamoun ◽  
...  

Abstract Purpose To assess clinical results of the 9 mW/5.4 J/cm2 accelerated crosslinking (ACXL) in the treatment of progressive keratoconus (KC) over a span of 5 years. Methods The prospective open non-randomized interventional study (Siena Eye-Cross Study 2) included 156 eyes of 112 patients with early progressive KC undergoing the Epi-Off 9 mW/5.4 J/cm2 ACXL at the Siena Crosslinking Centre, Italy. The mean age was 18.05 ± 5.6 years. The 20-min treatments were performed using the New KXL I (Avedro, Waltham, USA), 10 min of 0.1% HPMC Riboflavin soaking (VibeX Rapid, Avedro, Waltham, USA) and 10 min of continuous-light UV-A irradiation. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), Kmax, coma, minimum corneal thickness (MCT), surface asymmetry index (SAI), endothelial cell count (ECC) were measured, and corneal OCT performed. Results UDVA and CDVA improved significantly at the 3rd (P = 0.028), Δ + 0.17 Snellen lines and 6th postoperative month, respectively (P < 0.001), Δ + 0.23 Snellen lines. Kmax improved at the 6th postoperative month (P = 0.03), Δ − 1.49 diopters from the baseline value. Also, coma aberration value improved significantly (P = 0.004). A mild temporary haze was recorded in 14.77% of patients without affecting visual acuity and without persistent complications. Corneal OCT revealed a mean demarcation line depth at 332.6 ± 33.6 μm. Conclusion The 5-year results of Epi-Off 9 mW/5.4 J/cm2 ACXL demonstrated statistically significant improvements in UCVA and CDVA, corneal curvature and corneal higher-order aberrations which confers a long-term stability for progressive ectasia. Based on the results of the Siena Eye-Cross Study 2, the 9 mW/5.4 J/cm2 ACXL is a candidate to be  the natural evolution of Epi-Off CXL treatment for the management of early progressive corneal ectasia, and thus optimize clinic workflow.


2021 ◽  
pp. 112067212110143
Author(s):  
Luca Pagano ◽  
Kunal A Gadhvi ◽  
Giulia Coco ◽  
Matthew Fenech ◽  
Mitchell Titley ◽  
...  

Purpose: To compare the clinical outcomes of eye bank preloaded Descemet stripping automated endothelial keratoplasty (DSAEK) grafts and surgeon prepared. Methods: In this retrospective study, the data were obtained from two groups (a) surgeon cut DSAEK where tissue was prepared by the surgeon immediately before surgery, and (b) preloaded DSAEK tissue shipped to the surgeon after preparation by the eye bank. Standard DSAEK preparations using Moria microkeratome with single pass method were performed. For the tissues prepared by the eye banks, they were preloaded in an iGlide device and shipped in transport media. Standard DSAEK surgery using bimanual pull-through technique was performed for all the grafts. Air was used as a tamponade. Main outcome measures included best corrected visual acuity (BCVA) and rebubbling rate. Result: Out of 107 eyes of 101 patients that underwent DSAEK surgery, 33 tissues were prepared by the surgeon (sc-DSAEK), while 74 were prepared by the eye bank (pl-DSAEK). sc-DSAEK showed a rebubbling rate of 9.1%, compared to the 16.2% for the preloaded DSAEK ( p = 0.11). There was no statistical difference in postoperative BCVA between the two groups. Logistic regression analysis showed no association between detachment rate and cataract surgery, graft preparation method, graft diameter and reason for graft. Conclusion: Preloaded grafts have similar rebubbling rate and visual acuity achieved compared with surgeon prepared grafts.


2021 ◽  
pp. 1-8
Author(s):  
M. Florencia Ricci ◽  
Alastair Fung ◽  
Diane Moddemann ◽  
Victoria Micek ◽  
Gwen Y. Bond ◽  
...  

Abstract This comparison study of two groups within an inception cohort aimed to compare the frequency of motor impairment between preschool children with univentricular and biventricular critical congenital heart disease (CHD) not diagnosed with cerebral palsy/acquired brain injury, describe and compare their motor profiles and explore predictors of motor impairment in each group. Children with an intellectual quotient <70 or cerebral palsy/acquired brain injury were excluded. Motor skills were assessed with the Movement Assessment Battery for Children-2. Total scores <5th percentile indicated motor impairment. Statistical analysis included χ2 test and multiple logistic regression analysis. At a mean age of 55.4 (standard deviation 3.77) months, motor impairment was present in 11.8% of those with biventricular critical CHD, and 32.4% (p < 0.001) of those with univentricular critical CHD. The greatest difference between children with biventricular and univentricular CHD was seen in total test scores 8.73(2.9) versus 6.44(2.8) (p < 0.01) and in balance skills, 8.84 (2.8) versus 6.97 (2.5) (p = 0.001). Manual dexterity mean scores of children with univentricular CHD were significantly below the general population mean (>than one standard deviation). Independent odds ratio for motor impairment in children with biventricular critical CHD was presence of chromosomal abnormality, odds ratio 10.9 (CI 2.13–55.8) (p = 0.004); and in children with univentricular critical CHD odds ratio were: postoperative day 1–5 highest lactate (mmol/L), OR: 1.65 (C1.04–2.62) (p = 0.034), and dialysis requirement any time before the 4.5-year-old assessment, OR: 7.8 (CI 1.08–56.5) (p = 0.042). Early assessment of motor skills, particularly balance and manual dexterity, allows for intervention and supports that can address challenges during the school years.


2021 ◽  
pp. 112067212110183
Author(s):  
Yasin Cinar ◽  
Cagla Cilem Han ◽  
Alparslan Sahin ◽  
Zeba A Syed

Purpose: To evaluate the long term visual, refractive, and corneal tomographic outcomes of epithelium-off accelerated corneal collagen cross-linking (ACXL) in the management of pediatric keratoconus (KC). Methods: This retrospective study included patients under 18 years old with progressive KC who underwent ACXL between 2012 and 2019 at Dicle University Hospital. Complete ophthalmic examination was performed including uncorrected distance visual acuity (UDVA), best spectacle-corrected distance visual acuity (CDVA), manifest refraction, and corneal tomography. Evaluations were performed preoperatively and at 6 months intervals postoperatively. Results: Forty-nine eyes of 49 patients were included in the study. The mean age of patients at the time of ACXL was 14.2 ± 1.8 (range: 9.5–17.3) years. Mean follow up was 4.61 ± 1.90 (range: 2.0–8.1) years. The mean LogMAR UDVA improved from 0.94 ± 0.41 to 0.81 ± 0.43, 0.69 ± 0.41, and 0.67 ± 0.33 after 1, 3, and 5 years respectively ( p = 0.001). The mean LogMAR CDVA improved from 0.58 ± 0.36 to 0.46 ± 0.31, 0.34 ± 0.23, and 0.39 ± 0.27 after 1, 3, and 5 years respectively ( p = 0.015). The mean refractive cylinder improved significantly from 6.01 ± 2.07 diopters (D) to 5.46 ± 1.87, 5.38 ± 2.18, and 5.02 ± 2.31 D after 1, 3, and 5 years respectively ( p = 0.005). As compared to preoperative values, steep keratometry and maximum keratometry were not significantly different ( p = 0.805 and 0.448, respectively) following ACXL, while flat keratometry significantly improved after ACXL ( p = 0.012). Although central corneal thicknesses decreased significantly ( p = 0.029), the decrease in thinnest corneal thickness was not statistically significant ( p = 0.205). Conclusion: Epithelium-off ACXL seems to be effective for halting KC progression with long term clinical benefits in pediatric patients.


Ophthalmology ◽  
2009 ◽  
Vol 116 (1) ◽  
pp. 145-153 ◽  
Author(s):  
Susan A. Cotter ◽  
Kristina Tarczy-Hornoch ◽  
Erin Song ◽  
Jesse Lin ◽  
Mark Borchert ◽  
...  

2018 ◽  
Vol 30 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Guilherme Andrade do Nascimento Rocha ◽  
Paulo Ferrara de Almeida Cunha ◽  
Leonardo Torquetti Costa ◽  
Luciene Barbosa de Sousa

Importance: This study shows that a newer long-arc length intrastromal corneal ring segment is efficient and safe for keratoconus treatment. Background: To evaluate visual, tomographic results and complications of a 320-degree intrastromal corneal ring segment implantation with the femtosecond laser for keratoconus treatment. Design: A prospective, nonrandomized, and interventional study. Participants: A total of 34 eyes of 31 patients diagnosed with keratoconus were enrolled. Methods: Patients were divided into two groups based on the strategy used for 320-degree intrastromal corneal ring segment thickness selection. In one group, this selection was based on spherical equivalent (SE group) and in the other on the mean asphericity (Q group). The uncorrected and corrected distance visual acuities, spherical equivalent, K1, K2, Km, Kmax, and mean asphericity ( Q) on corneal tomography were evaluated preoperatively and at 3 and 6 months postoperatively. For astigmatism improvement, we analyzed the corneal tomographic vectorial astigmatism change preoperatively and at 6 months postoperatively. The mean follow-up period was 6.63 ± 0.96 months. Results: The mean uncorrected distance visual acuity and corrected distance visual acuity improved with a significant spherical equivalent improvement ( p < 0.05), with no differences between the 320-degree intrastromal corneal ring segment groups. All corneal tomographic parameters improved significantly ( p < 0.05) between the preoperative and postoperative intervals, with a significant better performance when we used spherical equivalent for the 320-degree intrastromal corneal ring segment thickness selection. Finally, the mean vectorial corneal tomographic astigmatism significantly improved after 6 months, again with no differences between groups. Conclusion: This study suggests that implanting a 320-degree intrastromal corneal ring segment is a safe and effective procedure for treating patients with keratoconus. It also suggests that for thickness selection spherical equivalent is the better strategy.


2018 ◽  
Vol 29 (2) ◽  
pp. 210-215 ◽  
Author(s):  
Marta Misiuk-Hojlo ◽  
Maria Pomorska ◽  
Malgorzata Mulak ◽  
Marek Rekas ◽  
Joanna Wierzbowska ◽  
...  

Purpose: To assess tolerability and efficacy following a switch from benzalkonium chloride–latanoprost to preservative-free latanoprost in patients with glaucoma or ocular hypertension. Methods: A total of 140 patients with glaucoma or ocular hypertension controlled with benzalkonium chloride-latanoprost for at least 3 months were switched to treatment with preservative-free latanoprost. Assessments were made on days 15, 45, and 90 (D15, D45, and D90) and included best-corrected visual acuity, intraocular pressure, slit lamp examination, fluorescein staining, tear film break-up time, patient symptom evaluation, and subjective estimation of tolerability. Results: Mean best-corrected visual acuity remained unchanged during the study. Mean intraocular pressure compared with baseline (D0) remained stable throughout the study (D0, 15.9 mmHg (standard deviation = 2.6); D90, 15.3 mmHg (standard deviation = 2.4); p < 0.006). Tear film break-up time improved or remained unchanged relative to baseline in 92% of patients at D45 and in 93% at D90. Moderate-to-severe conjunctival hyperemia was seen in 56.8% of patients at D0, but this figure decreased to 13.7%, 2.2%, and 1.6% at D15, D45, and D90, respectively. Subjective assessment of tolerability (0–10 scale) indicated improvement with change of therapy (mean score: 5.3 (standard deviation = 2.2) at D0 versus 1.9 (standard deviation = 1.7) at D90; p < 0.0001). Conclusion: Preservative-free latanoprost has at least the same intraocular pressure-lowering efficacy as benzalkonium chloride–latanoprost, with a better tolerability profile. This may translate into greater control of treatment and improved quality of life.


1993 ◽  
Vol 77 (1) ◽  
pp. 104-106
Author(s):  
Anne E. Kozlowski

The self-concepts of 10 5-yr.-old girls enrolled in a preballet program at a ballet school in Tulsa, Oklahoma for over one year were measured using the Purdue Self-concept Scale for Preschool Children. Their scores were compared against the scale's normative data for girls of similar age. A one-sample two-tailed t test showed girls' mean was 1 standard deviation above the normative population's mean, a significant difference. Preballet education may be an effective tool for enhancing self-concept, although selective factors may contribute also.


Sign in / Sign up

Export Citation Format

Share Document