scholarly journals Nanotechnology, Nanoparticles and Nanoscience: A New Approach in Chemistry and Life Sciences

2020 ◽  
Vol 10 (02) ◽  
pp. 17-26
Author(s):  
Dan Tshiswaka Dan
Keyword(s):  
2020 ◽  
Vol 16 (4) ◽  
Author(s):  
Marcel Friedrichs ◽  
Alban Shoshi ◽  
Piotr Jaroslaw Chmura ◽  
Jon Ison ◽  
Veit Schwämmle ◽  
...  

AbstractJIB.tools 2.0 is a new approach to more closely embed the curation process in the publication process. This website hosts the tools, software applications, databases and workflow systems published in the Journal of Integrative Bioinformatics (JIB). As soon as a new tool-related publication is published in JIB, the tool is posted to JIB.tools and can afterwards be easily transferred to bio.tools, a large information repository of software tools, databases and services for bioinformatics and the life sciences. In this way, an easily-accessible list of tools is provided which were published in JIB a well as status information regarding the underlying service. With newer registries like bio.tools providing these information on a bigger scale, JIB.tools 2.0 closes the gap between journal publications and registry publication. (Reference: https://jib.tools).


Physiology ◽  
1993 ◽  
Vol 8 (1) ◽  
pp. 7-12 ◽  
Author(s):  
DL Eckberg ◽  
JM Fritsch

A new approach to the study of arterial baroreflexes was developed for use during the National Aeronautics and Space Administration Spacelab Life Sciences-1 Space Shuttle mission. This method holds promise as a means to characterize the vagal limb of human baroreflex responses comprehensively and efficiently.


2017 ◽  
Vol 3 (2) ◽  
pp. 116-120 ◽  
Author(s):  
Zhaohua Yang ◽  
Nan Zhang ◽  
Yuzhe Sun ◽  
Yuanjin Yu

Ghost imaging (GI) has characteristics that make it promising for applications in life sciences and other fields, such as its high sensitivity and strong anti-interference compared with traditional imaging. This paper presents a new approach for online angiography using GI. Two signals are correlation-calculated to detect the object image: one of them is the random light field generated by a computer, and the other enters the optical fiber path after being transmitted to the detected object via a modulator. A new approach for the real-time imaging of intravascular flow, vascular wall structures, and components of atherosclerotic plaque is proposed, which has the advantages of a high sensitivity and anti-interference.


1984 ◽  
Vol 3 (1) ◽  
pp. 87-91 ◽  
Author(s):  
Franco P. Rota

In Western Europe and especially West Germany, introducing a new approach in political science, biopolitics, is not an easy task. German political science has a very strong and effective philosophical tradition (Aristotle, Aquinas, Kant, Hegel, Marx, Weber), which separates it from the life sciences. Traditionally, political science is a theoretical branch of study, and politics is regarded principally as a rational process. Based on well-known historical experiences, German social scientists raise ideological objections to biology, and, with some exceptions (Flohr, 1979, 1983; Buhl, 1981, 1982), they neglect the findings of the life sciences. Political science mainly operates in a vacuum, adhering to the discipline's traditional monistic conceptions of what politics ought to be. Thus, in Germany the first problem is how to change monistic approaches and create a new kind of scientific conception of the world, one that is open and dynamic (Radnitzky, 1971) and able to integrate findings from the life sciences. Only then can biopolitical perspectives become anchored in the discipline. Thus, introducing biopolitics in Germany depends on a mental change, from traditional monistic conceptions to an open conception.


1999 ◽  
Vol 173 ◽  
pp. 185-188
Author(s):  
Gy. Szabó ◽  
K. Sárneczky ◽  
L.L. Kiss

AbstractA widely used tool in studying quasi-monoperiodic processes is the O–C diagram. This paper deals with the application of this diagram in minor planet studies. The main difference between our approach and the classical O–C diagram is that we transform the epoch (=time) dependence into the geocentric longitude domain. We outline a rotation modelling using this modified O–C and illustrate the abilities with detailed error analysis. The primary assumption, that the monotonity and the shape of this diagram is (almost) independent of the geometry of the asteroids is discussed and tested. The monotonity enables an unambiguous distinction between the prograde and retrograde rotation, thus the four-fold (or in some cases the two-fold) ambiguities can be avoided. This turned out to be the main advantage of the O–C examination. As an extension to the theoretical work, we present some preliminary results on 1727 Mette based on new CCD observations.


Author(s):  
V. Mizuhira ◽  
Y. Futaesaku

Previously we reported that tannic acid is a very effective fixative for proteins including polypeptides. Especially, in the cross section of microtubules, thirteen submits in A-tubule and eleven in B-tubule could be observed very clearly. An elastic fiber could be demonstrated very clearly, as an electron opaque, homogeneous fiber. However, tannic acid did not penetrate into the deep portion of the tissue-block. So we tried Catechin. This shows almost the same chemical natures as that of proteins, as tannic acid. Moreover, we thought that catechin should have two active-reaction sites, one is phenol,and the other is catechole. Catechole site should react with osmium, to make Os- black. Phenol-site should react with peroxidase existing perhydroxide.


Author(s):  
K. Chien ◽  
R. Van de Velde ◽  
I.P. Shintaku ◽  
A.F. Sassoon

Immunoelectron microscopy of neoplastic lymphoma cells is valuable for precise localization of surface antigens and identification of cell types. We have developed a new approach in which the immunohistochemical staining can be evaluated prior to embedding for EM and desired area subsequently selected for ultrathin sectioning.A freshly prepared lymphoma cell suspension is spun onto polylysine hydrobromide- coated glass slides by cytocentrifugation and immediately fixed without air drying in polylysine paraformaldehyde (PLP) fixative. After rinsing in PBS, slides are stained by a 3-step immunoperoxidase method. Cell monolayer is then fixed in buffered 3% glutaraldehyde prior to DAB reaction. After the DAB reaction step, wet monolayers can be examined under LM for presence of brown reaction product and selected monolayers then processed by routine methods for EM and embedded with the Chien Re-embedding Mold. After the polymerization, the epoxy blocks are easily separated from the glass slides by heatingon a 100°C hot plate for 20 seconds.


Author(s):  
W. A. Chiou ◽  
N. Kohyama ◽  
B. Little ◽  
P. Wagner ◽  
M. Meshii

The corrosion of copper and copper alloys in a marine environment is of great concern because of their widespread use in heat exchangers and steam condensers in which natural seawater is the coolant. It has become increasingly evident that microorganisms play an important role in the corrosion of a number of metals and alloys under a variety of environments. For the past 15 years the use of SEM has proven to be useful in studying biofilms and spatial relationships between bacteria and localized corrosion of metals. Little information, however, has been obtained using TEM capitalizing on its higher spacial resolution and the transmission observation of interfaces. The research presented herein is the first step of this new approach in studying the corrosion with biological influence in pure copper.Commercially produced copper (Cu, 99%) foils of approximately 120 μm thick exposed to a copper-tolerant marine bacterium, Oceanospirillum, and an abiotic culture medium were subsampled (1 cm × 1 cm) for this study along with unexposed control samples.


Author(s):  
Arthur V. Jones

With the introduction of field-emission sources and “immersion-type” objective lenses, the resolution obtainable with modern scanning electron microscopes is approaching that obtainable in STEM and TEM-but only with specific types of specimens. Bulk specimens still suffer from the restrictions imposed by internal scattering and the need to be conducting. Advances in coating techniques have largely overcome these problems but for a sizeable body of specimens, the restrictions imposed by coating are unacceptable.For such specimens, low voltage operation, with its low beam penetration and freedom from charging artifacts, is the method of choice.Unfortunately the technical dificulties in producing an electron beam sufficiently small and of sufficient intensity are considerably greater at low beam energies — so much so that a radical reevaluation of convential design concepts is needed.The probe diameter is usually given by


Sign in / Sign up

Export Citation Format

Share Document