scholarly journals Satellite measurements of peroxyacetyl nitrate from the Cross-Track Infrared Sounder: Comparison with ATom aircraft measurements

2021 ◽  
Author(s):  
Vivienne H. Payne ◽  
Susan S. Kulawik ◽  
Emily V. Fischer ◽  
Jared F. Brewer ◽  
L. Gregory Huey ◽  
...  

Abstract. We present an overview of an optimal estimation algorithm to retrieve peroxyacetyl nitrate (PAN) from single field of view Level 1B radiances measured by the Cross-Track Infrared Sounder (CrIS). CrIS PAN retrievals show peak sensitivity in the mid-troposphere, with degrees of freedom for signal less than or equal to 1.0. We show comparisons with two sets of aircraft measurements from the Atmospheric Tomography Mission (ATom), the PAN and Trace Hydrohalocarbon ExpeRiment (PANTHER) and the Georgia Tech Chemical Ionization Mass Spectrometer (GT-CIMS). We find a systematic difference between the two aircraft datasets, with vertically averaged mid-tropospheric values from the GT-CIMS around 14 % lower than equivalent values from the PANTHER. However, the two sets of aircraft measurements are strongly correlated (R2 value of 0.92) and do provide a consistent view of the large-scale variation of PAN. We demonstrate that the retrievals of PAN from CrIS show skill in measurement of these large-scale PAN distributions in the remote mid-troposphere compared to the retrieval prior. The standard deviation of individual CrIS-aircraft differences is 0.08 ppbv, which we take as an estimate of the uncertainty of the CrIS mid-tropospheric PAN for a single satellite field of view. The standard deviation of the CrIS-aircraft comparisons for averaged CrIS retrievals (median of 20 satellite co-incidences with each aircraft profile) is lower, at 0.05 ppbv. This would suggest that the retrieval error reduces with averaging, although not with the square root of the number of observations. We find a negative bias of order 0.1 ppbv in the CrIS PAN results with respect to the aircraft measurements. This bias does not appear to show a dependence on latitude or season.

2021 ◽  
Author(s):  
Julieta F. Juncosa Calahorrano ◽  
Vivienne H. Payne ◽  
Susan Kulawik ◽  
Bonne Ford ◽  
Frank Flocke ◽  
...  

2013 ◽  
Vol 6 (9) ◽  
pp. 2255-2265 ◽  
Author(s):  
X. Xiong ◽  
C. Barnet ◽  
E. S. Maddy ◽  
A. Gambacorta ◽  
T. S. King ◽  
...  

Abstract. Mid-upper tropospheric methane (CH4), as an operational product at NOAA's (National Oceanic and Atmospheric Administration) Comprehensive Large Array-data Stewardship System (CLASS), has been retrieved from the Infrared Atmospheric Sounding Interferometer (IASI) since 2008. This paper provides a description of the retrieval method and the validation using 596 CH4 vertical profiles from aircraft measurements by the HIAPER Pole-to-Pole Observations (HIPPO) program over the Pacific Ocean. The number of degrees of freedom for the CH4 retrieval is mostly less than 1.5, and it decreases under cloudy conditions. The retrievals show greatest sensitivity between 100–600 hPa in the tropics and 200–750 hPa in the mid- to high latitude. Validation is accomplished using aircraft measurements (convolved by applying the monthly mean averaging kernels) collocated with all the retrieved profiles within 200 km and on the same day, and the results show that, on average, a larger error of CH4 occurs at 300–500 hPa. The bias in the trapezoid of 374–477 hPa is −1.74% with a residual standard deviation of 1.20%, and at layer 596–753 hPa the bias is −0.69% with a residual standard deviation of 1.07%. The retrieval error is relatively larger in the high northern latitude regions and/or under cloudy conditions. The main reasons for this negative bias include the uncertainty in the spectroscopy near the methane Q branch and/or the empirical bias correction, plus residual cloud contamination in the cloud-cleared radiances. It is expected for NOAA to generate the CH4 product for 20 + years using a similar algorithm from three similar thermal infrared sensors: Atmospheric Infrared Sounder (AIRS), IASI and the Cross-track Infrared Sounder (CrIS). Such a unique product will provide a supplementary to the current ground-based observation network, particularly in the Arctic, for monitoring the CH4 cycle, its transport and trend associated with climate change.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3598
Author(s):  
Sara Russo ◽  
Pasquale Contestabile ◽  
Andrea Bardazzi ◽  
Elisa Leone ◽  
Gregorio Iglesias ◽  
...  

New large-scale laboratory data are presented on a physical model of a spar buoy wind turbine with angular motion of control surfaces implemented (pitch control). The peculiarity of this type of rotating blade represents an essential aspect when studying floating offshore wind structures. Experiments were designed specifically to compare different operational environmental conditions in terms of wave steepness and wind speed. Results discussed here were derived from an analysis of only a part of the whole dataset. Consistent with recent small-scale experiments, data clearly show that the waves contributed to most of the model motions and mooring loads. A significant nonlinear behavior for sway, roll and yaw has been detected, whereas an increase in the wave period makes the wind speed less influential for surge, heave and pitch. In general, as the steepness increases, the oscillations decrease. However, higher wind speed does not mean greater platform motions. Data also indicate a significant role of the blade rotation in the turbine thrust, nacelle dynamic forces and power in six degrees of freedom. Certain pairs of wind speed-wave steepness are particularly unfavorable, since the first harmonic of the rotor (coupled to the first wave harmonic) causes the thrust force to be larger than that in more energetic sea states. The experiments suggest that the inclusion of pitch-controlled, variable-speed blades in physical (and numerical) tests on such types of structures is crucial, highlighting the importance of pitch motion as an important design factor.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1091
Author(s):  
Izaak Van Crombrugge ◽  
Rudi Penne ◽  
Steve Vanlanduit

Knowledge of precise camera poses is vital for multi-camera setups. Camera intrinsics can be obtained for each camera separately in lab conditions. For fixed multi-camera setups, the extrinsic calibration can only be done in situ. Usually, some markers are used, like checkerboards, requiring some level of overlap between cameras. In this work, we propose a method for cases with little or no overlap. Laser lines are projected on a plane (e.g., floor or wall) using a laser line projector. The pose of the plane and cameras is then optimized using bundle adjustment to match the lines seen by the cameras. To find the extrinsic calibration, only a partial overlap between the laser lines and the field of view of the cameras is needed. Real-world experiments were conducted both with and without overlapping fields of view, resulting in rotation errors below 0.5°. We show that the accuracy is comparable to other state-of-the-art methods while offering a more practical procedure. The method can also be used in large-scale applications and can be fully automated.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3425
Author(s):  
Andreas Brotzer ◽  
Felix Bernauer ◽  
Karl Ulrich Schreiber ◽  
Joachim Wassermann ◽  
Heiner Igel

In seismology, an increased effort to observe all 12 degrees of freedom of seismic ground motion by complementing translational ground motion observations with measurements of strain and rotational motions could be witnessed in recent decades, aiming at an enhanced probing and understanding of Earth and other planetary bodies. The evolution of optical instrumentation, in particular large-scale ring laser installations, such as G-ring and ROMY (ROtational Motion in seismologY), and their geoscientific application have contributed significantly to the emergence of this scientific field. The currently most advanced, large-scale ring laser array is ROMY, which is unprecedented in scale and design. As a heterolithic structure, ROMY’s ring laser components are subject to optical frequency drifts. Such Sagnac interferometers require new considerations and approaches concerning data acquisition, processing and quality assessment, compared to conventional, mechanical instrumentation. We present an automated approach to assess the data quality and the performance of a ring laser, based on characteristics of the interferometric Sagnac signal. The developed scheme is applied to ROMY data to detect compromised operation states and assign quality flags. When ROMY’s database becomes publicly accessible, this assessment will be employed to provide a quality control feature for data requests.


1995 ◽  
Vol 284 ◽  
pp. 171-216 ◽  
Author(s):  
N. T. Clemens ◽  
M. G. Mungal

Experiments were conducted in a two-stream planar mixing layer at convective Mach numbers,Mc, of 0.28, 0.42, 0.50, 0.62 and 0.79. Planar laser Mie scattering (PLMS) from a condensed alcohol fog and planar laser-induced fluorescence (PLIF) of nitric oxide were used for flow visualization in the side, plan and end views. The PLIF signals were also used to characterize the turbulent mixture fraction fluctuations.Visualizations using PLMS indicate a transition in the turbulent structure from quasi-two-dimensionality at low convective Mach number, to more random three-dimensionality for$M_c\geqslant 0.62$. A transition is also observed in the core and braid regions of the spanwise rollers as the convective Mach number increases from 0.28 to 0.62. A change in the entrainment mechanism with increasing compressibility is also indicated by signal intensity profiles and perspective views of the PLMS and PLIF images. These show that atMc= 0.28 the instantaneous mixture fraction field typically exhibits a gradient in the streamwise direction, but is more uniform in the cross-stream direction. AtMc= 0.62 and 0.79, however, the mixture fraction field is more streamwise uniform and with a gradient in the cross-stream direction. This change in the composition of the structures is indicative of different entrainment motions at the different compressibility conditions. The statistical results are consistent with the qualitative observations and suggest that compressibility acts to reduce the magnitude of the mixture fraction fluctuations, particularly on the high-speed edge of the layer.


2013 ◽  
Vol 16 ◽  
Author(s):  
Mónica Teresa González-Ramírez ◽  
María Noel Rodríguez-Ayán ◽  
René Landero Hernández

AbstractOne of the most widely used scales for the evaluation of stress is the Perceived Stress Scale (PSS), and it has been adapted into different languages. However, few studies have presented normative data from large samples, and there do not appear to be any studies of the PSS that provide normative data based on large samples for Mexico. Thus, the goal of this study was to provide normative data regarding gender and different age groups for a sample of 1990 Mexican subjects to validate the factor structure of the construct for this sample. The analysis of the 10- and 14-item versions of the PSS revealed that the scale had adequate reliability and that the factor structure was consistent with previous studies. With respect to the normative data, the means of the different groups ranged from 20.93 to 25.63 for the PSS14 and from 14.52 to 17.73 for the PSS10. We propose that scores within one standard deviation of these means be used as reference values for each group.


2014 ◽  
Vol 496-500 ◽  
pp. 1643-1647
Author(s):  
Ying Feng Wu ◽  
Gang Yan Li

IR-based large scale volume localization system (LSVLS) can localize the mobile robot working in large volume, which is constituted referring to the MSCMS-II. Hundreds cameras in LSVLS must be connected to the control station (PC) through network. Synchronization of cameras which are mounted on different control stations is significant, because the image acquisition of the target must be synchronous to ensure that the target is localized precisely. Software synchronization method is adopted to ensure the synchronization of camera. The mean value of standard deviation of eight cameras mounted on two workstations is 12.53ms, the localization performance of LSVLS is enhanced.


2021 ◽  
Author(s):  
Lin Huang ◽  
Kun Qian

Abstract Early cancer detection greatly increases the chances for successful treatment, but available diagnostics for some tumours, including lung adenocarcinoma (LA), are limited. An ideal early-stage diagnosis of LA for large-scale clinical use must address quick detection, low invasiveness, and high performance. Here, we conduct machine learning of serum metabolic patterns to detect early-stage LA. We extract direct metabolic patterns by the optimized ferric particle-assisted laser desorption/ionization mass spectrometry within 1 second using only 50 nL of serum. We define a metabolic range of 100-400 Da with 143 m/z features. We diagnose early-stage LA with sensitivity~70-90% and specificity~90-93% through the sparse regression machine learning of patterns. We identify a biomarker panel of seven metabolites and relevant pathways to distinguish early-stage LA from controls (p < 0.05). Our approach advances the design of metabolic analysis for early cancer detection and holds promise as an efficient test for low-cost rollout to clinics.


Sign in / Sign up

Export Citation Format

Share Document