Particle Induced X-ray Emission at Mercury and the Moon.

Author(s):  
Manuel Grande ◽  
Rose Cooper

<p>Mercury and the Moon are examples of terrestrial bodies which lack an atmosphere and therefore have surfaces which interact directly with the space environment. Thus the surfaces can be reprocessed by plasma impact, and in the process can emit X-rays via the Particle Induced X-ray Emission (PIXE) process. We will present and review existing measurements, particularly from SMART-1 and Chandrayaan at the Moon, and Messenger and Mercury, in order to predict opportunities for new science at Mercury by BepiColumbo. We will present predictions of PIXE signals from different regions of the Mercury surface, and examine the possibility of using the signal for direct diagnosis of particle interactions with the surface. These include the auroral signatures of substorm like behaviour, and interactions with coronal mass ejections.</p>

1994 ◽  
Vol 144 ◽  
pp. 82
Author(s):  
E. Hildner

AbstractOver the last twenty years, orbiting coronagraphs have vastly increased the amount of observational material for the whitelight corona. Spanning almost two solar cycles, and augmented by ground-based K-coronameter, emission-line, and eclipse observations, these data allow us to assess,inter alia: the typical and atypical behavior of the corona; how the corona evolves on time scales from minutes to a decade; and (in some respects) the relation between photospheric, coronal, and interplanetary features. This talk will review recent results on these three topics. A remark or two will attempt to relate the whitelight corona between 1.5 and 6 R⊙to the corona seen at lower altitudes in soft X-rays (e.g., with Yohkoh). The whitelight emission depends only on integrated electron density independent of temperature, whereas the soft X-ray emission depends upon the integral of electron density squared times a temperature function. The properties of coronal mass ejections (CMEs) will be reviewed briefly and their relationships to other solar and interplanetary phenomena will be noted.


2018 ◽  
Vol 8 ◽  
pp. A47 ◽  
Author(s):  
Stephen W. Kahler ◽  
Alan. G. Ling

Solar flare X-ray peak fluxes and fluences in the 0.1–0.8 nm band are often used in models to forecast solar energetic particle (SEP) events. Garcia (2004) [Forecasting methods for occurrence and magnitude of proton storms with solar soft X rays, Space Weather, 2, S02002, 2004] used ratios of the 0.05–0.4 and 0.1–0.8 nm bands of the X-ray instrument on the GOES spacecraft to plot inferred peak flare temperatures versus peak 0.1–0.8 nm fluxes for flares from 1988 to 2002. Flares associated with E > 10 MeV SEP events of >10 proton flux units (pfu) had statistically lower peak temperatures than those without SEP events and therefore offered a possible empirical forecasting tool for SEP events. We review the soft and hard X-ray flare spectral variations as SEP event forecast tools and repeat Garcia’s work for the period 1998–2016, comparing both the peak ratios and the ratios of the preceding 0.05–0.4 nm peak fluxes to the later 0.1–0.8 nm peak fluxes of flares >M3 to the occurrence of associated SEP events. We divide the events into eastern and western hemisphere sources and compare both small (1.2–10 pfu) and large (≥300 pfu) SEP events with those of >10 pfu. In the western hemisphere X-ray peak ratios are statistically lower for >10 pfu SEP events than for non-SEP events and are even lower for the large (>300 pfu) events. The small SEP events, however, are not distinguished from the non-SEP events. We discuss the possible connections between the flare X-ray peak ratios and associated coronal mass ejections that are presumed to be the sources of the SEPs.


2020 ◽  
Author(s):  
Sae Aizawa ◽  
Nicolas André ◽  
Ronan Modolo ◽  
François Leblanc ◽  
Elisabeth Werner ◽  
...  

<p><span lang="EN-US">The highly compressed magnetosphere (HCM) events at Mercury observed by the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft have been investigated using the global hybrid simulation LatHyS. The HCM events occur due to the interactions with coronal mass ejections (CMEs) or high-speed streams (HSSs) and previous studies indicate that not only the reconnection-driven erosion but also the induced currents in the inner core have an important role in the variation of the dayside magnetosphere of Mercury. However, the effects of the presence of planetary ions on Mercury’s system have not been well discussed. In this study, we mainly focus on the presence of planetary ions that are self-consistently produced from the exosphere by several ionization processes under extreme solar wind conditions and discuss their role on the structure and dynamics of Mercury’s magnetosphere.</span></p>


2020 ◽  
Vol 216 (8) ◽  
Author(s):  
Emma J. Bunce ◽  
Adrian Martindale ◽  
Simon Lindsay ◽  
Karri Muinonen ◽  
David A. Rothery ◽  
...  

AbstractThe Mercury Imaging X-ray Spectrometer is a highly novel instrument that is designed to map Mercury’s elemental composition from orbit at two angular resolutions. By observing the fluorescence X-rays generated when solar-coronal X-rays and charged particles interact with the surface regolith, MIXS will be able to measure the atomic composition of the upper ∼10-20 μm of Mercury’s surface on the day-side. Through precipitating particles on the night-side, MIXS will also determine the dynamic interaction of the planet’s surface with the surrounding space environment.MIXS is composed of two complementary elements: MIXS-C is a collimated instrument which will achieve global coverage at a similar spatial resolution to that achieved (in the northern hemisphere only – i.e. ∼ 50 – 100 km) by MESSENGER; MIXS-T is the first ever X-ray telescope to be sent to another planet and will, during periods of high solar activity (or intense precipitation of charged particles), reveal the X-ray flux from Mercury at better than 10 km resolution. The design, performance, scientific goals and operations plans of the instrument are discussed, including the initial results from commissioning in space.


Author(s):  
R. H. Duff

A material irradiated with electrons emits x-rays having energies characteristic of the elements present. Chemical combination between elements results in a small shift of the peak energies of these characteristic x-rays because chemical bonds between different elements have different energies. The energy differences of the characteristic x-rays resulting from valence electron transitions can be used to identify the chemical species present and to obtain information about the chemical bond itself. Although these peak-energy shifts have been well known for a number of years, their use for chemical-species identification in small volumes of material was not realized until the development of the electron microprobe.


Author(s):  
E. A. Kenik ◽  
J. Bentley

Cliff and Lorimer (1) have proposed a simple approach to thin foil x-ray analy sis based on the ratio of x-ray peak intensities. However, there are several experimental pitfalls which must be recognized in obtaining the desired x-ray intensities. Undesirable x-ray induced fluorescence of the specimen can result from various mechanisms and leads to x-ray intensities not characteristic of electron excitation and further results in incorrect intensity ratios.In measuring the x-ray intensity ratio for NiAl as a function of foil thickness, Zaluzec and Fraser (2) found the ratio was not constant for thicknesses where absorption could be neglected. They demonstrated that this effect originated from x-ray induced fluorescence by blocking the beam with lead foil. The primary x-rays arise in the illumination system and result in varying intensity ratios and a finite x-ray spectrum even when the specimen is not intercepting the electron beam, an ‘in-hole’ spectrum. We have developed a second technique for detecting x-ray induced fluorescence based on the magnitude of the ‘in-hole’ spectrum with different filament emission currents and condenser apertures.


Author(s):  
W. Brünger

Reconstructive tomography is a new technique in diagnostic radiology for imaging cross-sectional planes of the human body /1/. A collimated beam of X-rays is scanned through a thin slice of the body and the transmitted intensity is recorded by a detector giving a linear shadow graph or projection (see fig. 1). Many of these projections at different angles are used to reconstruct the body-layer, usually with the aid of a computer. The picture element size of present tomographic scanners is approximately 1.1 mm2.Micro tomography can be realized using the very fine X-ray source generated by the focused electron beam of a scanning electron microscope (see fig. 2). The translation of the X-ray source is done by a line scan of the electron beam on a polished target surface /2/. Projections at different angles are produced by rotating the object.During the registration of a single scan the electron beam is deflected in one direction only, while both deflections are operating in the display tube.


Author(s):  
L. T. Germinario

Understanding the role of metal cluster composition in determining catalytic selectivity and activity is of major interest in heterogeneous catalysis. The electron microscope is well established as a powerful tool for ultrastructural and compositional characterization of support and catalyst. Because the spatial resolution of x-ray microanalysis is defined by the smallest beam diameter into which the required number of electrons can be focused, the dedicated STEM with FEG is the instrument of choice. The main sources of errors in energy dispersive x-ray analysis (EDS) are: (1) beam-induced changes in specimen composition, (2) specimen drift, (3) instrumental factors which produce background radiation, and (4) basic statistical limitations which result in the detection of a finite number of x-ray photons. Digital beam techniques have been described for supported single-element metal clusters with spatial resolutions of about 10 nm. However, the detection of spurious characteristic x-rays away from catalyst particles produced images requiring several image processing steps.


Author(s):  
W. Z. Chang ◽  
D. B. Wittry

Since Du Mond and Kirkpatrick first discussed the principle of a bent crystal spectrograph in 1930, curved single crystals have been widely utilized as spectrometric monochromators as well as diffractors for focusing x rays diverging from a point. Curved crystal diffraction theory predicts that the diffraction parameters - the rocking curve width w, and the peak reflection coefficient r of curved crystals will certainly deviate from those of their flat form. Due to a lack of curved crystal parameter data in current literature and the need for optimizing the choice of diffraction geometry and crystal materials for various applications, we have continued the investigation of our technique presented at the last conference. In the present abstract, we describe a more rigorous and quantitative procedure for measuring the parameters of curved crystals.The diffraction image of a singly bent crystal under study can be obtained by using the Johann geometry with an x-ray point source.


Author(s):  
Shawn Williams ◽  
Xiaodong Zhang ◽  
Susan Lamm ◽  
Jack Van’t Hof

The Scanning Transmission X-ray Microscope (STXM) is well suited for investigating metaphase chromosome structure. The absorption cross-section of soft x-rays having energies between the carbon and oxygen K edges (284 - 531 eV) is 6 - 9.5 times greater for organic specimens than for water, which permits one to examine unstained, wet biological specimens with resolution superior to that attainable using visible light. The attenuation length of the x-rays is suitable for imaging micron thick specimens without sectioning. This large difference in cross-section yields good specimen contrast, so that fewer soft x-rays than electrons are required to image wet biological specimens at a given resolution. But most imaging techniques delivering better resolution than visible light produce radiation damage. Soft x-rays are known to be very effective in damaging biological specimens. The STXM is constructed to minimize specimen dose, but it is important to measure the actual damage induced as a function of dose in order to determine the dose range within which radiation damage does not compromise image quality.


Sign in / Sign up

Export Citation Format

Share Document