scholarly journals Rehabilitation of Shear-Damaged Reinforced Concrete Beams Using Self-Compacting Concrete Jacketing

2012 ◽  
Vol 2012 ◽  
pp. 1-12 ◽  
Author(s):  
Constantin E. Chalioris ◽  
Constantin N. Pourzitidis

The application of a reinforced self-compacting concrete jacket for the structural rehabilitation of shear damaged reinforced concrete beams is experimentally investigated. Five beams were constructed and subjected to monotonic loading in order to exhibit shear failure. The damaged specimens were restored using relatively thin reinforced jackets and retested by the same four-point bending loading. The self-compacting concrete jacket applied, encasing the bottom width and both vertical sides of the initially tested beams (U-formed jacketing), has a small thickness (25 mm) and includes small (5) steel bars and U-formed stirrups. Test results and comparisons between the experimental behaviour of the beams indicated that the examined jacketing technique is a reliable rehabilitation method since the capacity of the retrofitted beams was fully restored or ameliorated with respect to the initial specimens. Discussion of the ability of the applied jacket to enhance the overall structural performance of the examined beams and, potentially, to alter their failure mode to a more ductile one is also included. Calculations of the flexural and shear strength of the tested beams and evaluation of the monolithic factors for the capacity at yield and at ultimate of the jacketed beams were also performed and are commented on.

2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Constantin E. Chalioris ◽  
Constantin P. Papadopoulos ◽  
Constantin N. Pourzitidis ◽  
Dimitrios Fotis ◽  
Kosmas K. Sideris

This paper presents the findings of an experimental study on the application of a reinforced self-compacting concrete jacketing technique in damaged reinforced concrete beams. Test results of 12 specimens subjected to monotonic loading up to failure or under repeated loading steps prior to total failure are included. First, 6 beams were designed to be shear dominated, constructed by commonly used concrete, were initially tested, damaged, and failed in a brittle manner. Afterwards, the shear-damaged beams were retrofitted using a self-compacting concrete U-formed jacket that consisted of small diameter steel bars and U-formed stirrups in order to increase their shear resistance and potentially to alter their initially observed shear response to a more ductile one. The jacketed beams were retested under the same loading. Test results indicated that the application of reinforced self-compacting concrete jacketing in damaged reinforced concrete beams is a promising rehabilitation technique. All the jacketed beams showed enhanced overall structural response and 35% to 50% increased load bearing capacities. The ultimate shear load of the jacketed beams varied from 39.7 to 42.0 kN, whereas the capacity of the original beams was approximately 30% lower. Further, all the retrofitted specimens exhibited typical flexural response with high values of deflection ductility.


2021 ◽  
Vol 11 (4) ◽  
pp. 56-69
Author(s):  
Retno Anggraini ◽  
Tavio Tavio ◽  
Gusti Putu Raka ◽  
Agustiar Agustiar

High-strength steel bars have different characteristics from normal-strength steel bars. Thus, the use of high-strength steel bars still needs to be investigated further before it can be used confidently in concrete structures. In the design, a reinforced concrete beam should also have enough ductility besides its loading capacity. One of the indicators identifies that a structure has sufficient ductility is its ability to maintain the load steadily due to progressive deformation. This paper presents the test results of three reinforced concrete beams designed with concrete strength (fc) of 30 MPa. Two different yield strengths (fy) of longitudinal and transverse reinforcements were used, namely, 420 and 550 MPa. The cross-sectional dimensions of the beams were 200  300 mm with a total span of 2000 mm and a rigid stub at the midspan. The beams were simply supported by double rollers at their tops and bottoms. These special supports were located at both ends of the beams. The load applied at the midspan of the beam through the rigid stub with the displacement control. The loading pattern protocol by the drift was set from 0 to 5.5 percent. Based on the test results, it can be seen that the beams with high-strength steel bars could achieve a higher load capacity than the beams with normal-strength steel bars. On the other hand, the beams with high-strength steel bars produced lower deflection than the beams with normal-strength steel bars. Furthermore, it can be concluded that all the beams could withstand the minimum required of 3.5 percent. None of the beams indicated brittle failures. All of the beams could survived until the end of the cycles at a drift of 5.5 percent. This condition indicates that the reinforced concrete beams with higher-strength reinforcement (fy of 550 MPa) could also maintain their load capacities under large deformation beyond the first yielding of the longitudinal steel bars.


2020 ◽  
pp. 136943322095061
Author(s):  
Akhtar Gul ◽  
Bashir Alam ◽  
Wisal Ahmed ◽  
Nauman Wahab ◽  
Khan Shahzada ◽  
...  

Strengthening of structural members is a common practice around the world that may arise due to deterioration of concrete with age or upgradation of design code. This paper aims to elucidate a technique used for strengthening of the reinforced concrete beam for flexural capacity by using externally welded steel angles and steel bars. For this motive, three beams were strengthened with external steel angles and three with external steel bars. The external strengthening steel elements were attached at the bottom of the beam with shear reinforcement. Control samples without external steel angles and steel bars for comparison purposes were also prepared. All reinforced concrete beams were first constructed using a concrete ratio of 1:2:4, and then external steel elements were added to existing flexural reinforcement by using a fillet weld with tee joints having thickness and length of 5/16" (7.9 mm) and 6" (152.4 mm), respectively. Fourth point loading criteria were used to investigate the flexural capacity of beams in positive bending. All beams were designed strong enough in shear, to resist the ultimate loads without shear failure. Test results indicated that beams strengthened with this technique have an average increase of 238% with steel angles and 106% with steel bars, in load-carrying capacity than control samples. Strengthened beams showed a uniform crack pattern. Moreover, the concrete cover made a good bond with existing concrete and was strong enough to withstand ultimate loads. Conclusively, the steel angles and steel bars can be used as an external strengthening material, to enhance the flexural capacity of reinforced concrete beams.


2011 ◽  
Vol 243-249 ◽  
pp. 1461-1465
Author(s):  
Chuan Min Zhang ◽  
Chao He Chen ◽  
Ye Fan Chen

The paper makes an analysis of the reinforced concrete beams with exterior FRP Shell in Finite Element, and compares it with the test results. The results show that, by means of this model, mechanical properties of reinforced concrete beams with exterior FRP shell can be predicted better. However, the larger the load, the larger deviation between calculated values and test values. Hence, if more accurate calculation is required, issues of contact interface between the reinforced concrete beams and the FRP shell should be taken into consideration.


Sensors ◽  
2018 ◽  
Vol 18 (10) ◽  
pp. 3255 ◽  
Author(s):  
Fang Yuan ◽  
Mengcheng Chen

Fibre-reinforced polymer (FRP)-reinforced concrete members exhibit low ductility due to the linear-elastic behaviour of FRP materials. Concrete members reinforced by hybrid FRP–steel bars can improve strength and ductility simultaneously. In this study, the plastic hinge problem of hybrid FRP–steel reinforced concrete beams was numerically assessed through finite element analysis (FEA). Firstly, a finite element model was proposed to validate the numerical method by comparing the simulation results with the test results. Then, three plastic hinge regions—the rebar yielding zone, concrete crushing zone, and curvature localisation zone—of the hybrid reinforced concrete beams were analysed in detail. Finally, the effects of the main parameters, including the beam aspect ratio, concrete grade, steel yield strength, steel reinforcement ratio, steel hardening modulus, and FRP elastic modulus on the lengths of the three plastic zones, were systematically evaluated through parametric studies. It is determined that the hybrid reinforcement ratio exerts a significant effect on the plastic hinge lengths. The larger the hybrid reinforcement ratio, the larger is the extent of the rebar yielding zone and curvature localisation zone. It is also determined that the beam aspect ratio, concrete compressive strength, and steel hardening ratio exert significant positive effects on the length of the rebar yielding zone.


2012 ◽  
Vol 535-537 ◽  
pp. 1803-1806
Author(s):  
Shun Bo Zhao ◽  
Peng Bing Hou ◽  
Fu Lai Qu

An experimental study was carried out to examine the non-uniform corrosion of plain steel bars in reinforced concrete beams partially placed in 5% sodium chloride solution under conditions of accelerated corrosion. 4 reinforced concrete beams with different concrete strength were made. The crack distributions of the beams due to pre-loads and expansion of corrosion product, and the sectional corrosion characteristics of plain steel bars are described in detail. The sectional area loss relating to mass loss and change along pure bending length of the beams are discussed. These can be used as the basis of test for further studies to build the numerical models of serviceability of corroded reinforced concrete beams.


2018 ◽  
Vol 149 ◽  
pp. 01022 ◽  
Author(s):  
Khadra Bendjillali ◽  
Mohamed Chemrouk

The valorisation of industrial waste in the field of construction became a very interesting axis of research from scientific, economic and environmental point of view. We have conducted this work to study the effect of the addition of polypropylene fibres waste on the mechanical behaviour of reinforced concrete beams subjected to a simple flexural loading, with and without transversal reinforcement. The used fibres are coming from the waste of the fabrication of domestic brushes and sweeps; they have an average diameter of 0.47 mm and a length between 40 and 60 mm. Two weight dosages of fibres are used, 0.25 and 0.5 %. The experimental results showed that the incorporation of polypropylene fibres waste into the concrete affects negatively its workability, but its flexural and compressive strength are improved. The fibers have presented a significant contribution on the shear behavior and the cracking of beams, particularly in absence of transversal bars. The waste used in this work as fibrous reinforcement has not only increased the ductility of reinforced concrete beams, but it have also provided a perfect cracking distribution on the concrete surface and it has participated in a considerable way in the reduction of cracks number and dimensions, which allows to ensure the material durability and then the structure longevity. The reinforcement of concrete beams with 0.5 % of polypropylene fibers waste with a minimal steel bars can ensure an excellent mechanical behavior in shear, as in flexion.


2010 ◽  
Vol 37 (8) ◽  
pp. 1045-1056 ◽  
Author(s):  
Christopher Suffern ◽  
Ahmed El-Sayed ◽  
Khaled Soudki

This paper reports experimental data on the structural performance of disturbed regions in reinforced concrete beams with corrosion damage to the embedded steel stirrups. A total of 15 reinforced concrete beams were constructed and tested. The test beams were 350 mm deep, 125 mm wide, and 1850 mm long. The beams were tested in three-point bending under a simply supported span of 1500 mm. Nine beams had the embedded stirrups subjected to accelerated corrosion. The test variables were the corrosion damage level and the shear span-to-depth ratio. The test results indicated that the corroded beams exhibited reduced shear strength in comparison to the uncorroded control specimens. The shear strength reduction was up to 53%. Furthermore, the reduction in shear strength due to the corrosion was found to be greater at smaller shear span-to-depth ratios.