average percentage deviation
Recently Published Documents


TOTAL DOCUMENTS

7
(FIVE YEARS 4)

H-INDEX

1
(FIVE YEARS 0)

Author(s):  
Jéssica L. O. Brasileiro ◽  
Rossana M. F. de Figueirêdo ◽  
Alexandre J. de M. Queiroz ◽  
Regilane M. Feitosa

ABSTRACT Fruit pulps undergo temperature variations during processing, leading to viscosity changes. This study aimed to analyse the rheological behaviour of macaíba pulp at different temperatures (10 to 50 ºC, with 5 ºC increments) and speeds (2.5 to 200 rpm, totalling 17 speeds). Experimental measurements were performed in a Brookfield viscometer, fitting the Ostwald-de-Waele, Mizrahi-Berk, Herschel-Bulkley, and Casson models to the experimental data of shear stress as a function of shear rate. Among the models used, the Mizrahi-Berk model (R² > 0.9656 and average percentage deviation - P ≤ 4.1%) was found to best fit the rheogram data. Macaíba pulp exhibited a non-newtonian behaviour and was characterised as pseudoplastic. It showed fluid behaviour indexes below unity under the studied conditions, with decreases in apparent viscosity as temperature and shear rate increased. Such behaviour could be described by the Arrhenius equation. The Mizrahi-Berk and Falguera-Ibarz models (R² > 0.99 and P ≤ 10%) best fitted the data and were used to represent the viscosity behaviour of macaíba pulp. The activation energy values of macaíba pulp ranged between 17.53 and 25.37 kJ mol-1, showing a rheological behaviour like other fruit pulps.


Fuels ◽  
2021 ◽  
Vol 2 (1) ◽  
pp. 37-47
Author(s):  
Suzanna A. D’Souza ◽  
Shubhadeep Banik ◽  
Hari B. Vuthaluru ◽  
Sarma V. Pisupati

The viscosity of slag from an operating integrated gasification combined cycle (IGCC) plant utilising petroleum coke and a synthetic petcoke slag with the same composition made from chemical grade oxides in a reducing environment for gasification application were investigated in this study. A high temperature rotating bob-type viscometer was used to measure viscosity between temperatures of 1250–1375 °C. Natural and synthetic ash had similar viscosities above 1300 °C in this study. The viscosity was predicted by using FactSage, a thermodynamic modelling software, in conjunction with different viscosity models, available in the open literature. Percentage deviations of predicted viscosities from different models with experimentally measured values ranged from about 41 to 151%. Crystallisation of the slag was noted in SEM-EDS (scanning electron microscopy– energy dispersive spectroscopy) and FactSage results. Solid phases from FactSage predictions were used to modify the Kalmanovitch–Frank model with the Roscoe method. It predicted the viscosity of the slag accurately between 1250 and 1375 °C. Average percentage deviation from measured natural ash viscosity was about 11%.


2019 ◽  
Vol 70 (2) ◽  
pp. 475-482
Author(s):  
Cristian Catalin Gavat ◽  
Leonard Vasile Vasilescu ◽  
Afrodita Doina Marculescu

The aim of this research was to exactly quantify pure sodium metamizole from tablets , using a spectrophotometric analysis in Visible range. The method applied has been subjected to a validation protocal which consisted in analyzing the following parameters: linearity of the method, detection limit (LD) , quantitation limit (LQ), Sandell�s sensitivity, interference of excipients, stability of prepared solutions, method and system precision, accuracy of the method. Following actual dosing, pure sodium metamizole amount in tablet of pharmaceutical was found to be 477.477 mg assigned to a percentage content of 95.495 %, very close to official declared amount (500 mg), with an maximum average percentage deviation of only 4.505 % from the official declared active substance content. This value was situated below the maximum admissible percentage deviation from stated active substance content (� 5%), established by Romanian Pharmacopoeia, X-th Edition rules.


2019 ◽  
Vol 70 (1) ◽  
pp. 259-262
Author(s):  
Afrodita Doina Marculescu ◽  
Cristian-Catalin Gavat ◽  
Aurel Nechita ◽  
Gabi Topor ◽  
Leonard Vasile Vasilescu ◽  
...  

The aim of this research was to exactly quantify pure sodium metamizole from tablets , using a spectrophotometric analysis in Visible range. The method applied has been subjected to a validation protocal which consisted in analyzing the following parameters: linearity of the method, detection limit (LD) , quantitation limit (LQ). Following actual dosing, pure sodium metamizole amount in tablet of pharmaceutical was found to be 477.477 mg assigned to a percentage content of 95.495 %, very close to official declared amount (500 mg), with an maximum average percentage deviation of only 4.505 % from the official declared active substance content. This value was situated below the maximum admissible percentage deviation from stated active substance content (� 5%), established by Romanian Pharmacopoeia, X-th Edition rules.


2018 ◽  
Vol 2018 ◽  
pp. 1-11 ◽  
Author(s):  
Bei Zhou ◽  
Zongzhi Li ◽  
Shengrui Zhang

A hit-and-run (HR) crash occurs when the driver of the offending vehicle flees the crash scene without reporting it or aiding the victims. The current study aimed at contributing to existing literatures by comparing factors which might affect the crash severity in HR and non-hit-and-run (NHR) crashes. The data was extracted from the police-reported crash data from September 2017 to August 2018 within the City of Chicago. Two multinomial logistic regression models were established for the HR and NHR crash data, respectively. The odds ratio (OR) of each variable was used to quantify the impact of this variable on the crash severity. In both models, the property damage only (PDO) crash was selected as the reference group, and the injury and fatal crash were chosen as the comparison group. When the injury crash was taken as the comparison group, it was found that 12 variables contributed to the crash severities in both HR and NHR model. The average percentage deviation of OR for these 12 variables was 34%, indicating that compared with property damage, HR crashes were 34% more likely to result in injuries than NHR crashes on average. When fatal crashes were chosen as the comparison group, 2 variables were found to be statistically significant in both the HR and the NHR model. The average percentage deviation of OR for these 2 variables was 127%, indicating that compared with property damage, HR crashes were 127% more likely to result in fatalities than NHR crashes on average.


2016 ◽  
Vol 4 (2) ◽  
pp. 48
Author(s):  
Abdelhakim Latreche ◽  
Salah Daoud

In their recent work, Bahadur and Mishra proposed a new simple formula between the high-frequency refractive index and optical elec-tronegativity difference, which has been established for large number of ANB8-N type binary semiconductors (groups: I-VII, II-VI, III-V and IV-VI.). In the present work, we have improved their expression by addition a correction term in their proposed formula. The minimum average percentage deviation in the present approach reveals that the modified Bahadur relation proves its identity and soundness compared to that of Bahadur’s and others authors' relations.


2014 ◽  
Vol 2014 ◽  
pp. 1-4
Author(s):  
T. Muhammad ◽  
A. Uzairu ◽  
M. S. Sallau ◽  
M. O. A. Oladipo

The Nigerian Research Reactor-1 was employed in the analysis of iodine in local food samples at an operating flux of 5.0×1011 ncm−2 s−1. Preconcentration neutron activation analysis (PCNAA) was compared against the most common spectroscopic (Sandell-Kolthoff reaction) technique, giving a concentration range of 0.295 to 2.960 mg/Kg and 0.264 to 2.725 mg/Kg, respectively, with an average percentage deviation of 11.34% and a positive correlation between the methods at 0.89. PCNAA and Sandell-Kolthoff spectroscopy of NIST 1548a reported values of 0.759±0.06 mg/Kg and 0.751±0.05 with Student’s t-test score of 1 and 0.95 and percentage standard deviation of 0 and 1.12%, respectively.


Sign in / Sign up

Export Citation Format

Share Document