The Effect of Wind Velocity and Night Natural Ventilation on the Inside Air Temperature in Passive Cooling Ventilation in Arid Zones

Author(s):  
H. Bencheikh
2012 ◽  
Vol 433-440 ◽  
pp. 1194-1201
Author(s):  
Lu Hong Huang ◽  
En Shen Long ◽  
Zi Yun Wang ◽  
Bo Zhou ◽  
Lu Hong Huang ◽  
...  

In the summer of 2010, we performed some on-site measurements to investigate the outdoor air temperature and wind velocity of Happy Homeland, a typical post-earthquake transition settlement of Sichuan. With the results of the measurements we found some problems in the existing planning and design of the settlements and proposed improvement which can make the transition settlements have larger volume fraction and better ventilation environment. The CFD simulation results show that the improvement can enhance the outdoor wind velocity by 19.4% and 16.7% respectively, and can raise the air changes per hour by 44.4% and 63.7% respectively, compared with the present condition.


2020 ◽  
Vol 13 (1) ◽  
pp. 201
Author(s):  
Pau Chung Leng ◽  
Gabriel Hoh Teck Ling ◽  
Mohd Hamdan Ahmad ◽  
Dilshan Remaz Ossen ◽  
Eeydzah Aminudin ◽  
...  

The provision requirement of 10% openings of the total floor area stated in the Uniform Building By-Law 1984 Malaysia is essential for natural lighting and ventilation purposes. However, focusing on natural ventilation, the effectiveness of thermal performance in landed residential buildings has never been empirically measured and proven, as most of the research emphasized simulation modeling lacking sufficient empirical validation. Therefore, this paper drawing on field measurement investigates natural ventilation performance in terraced housing with an air-well system. The key concern as to what extent the current air-well system serving as a ventilator is effective to provide better thermal performance is to be addressed. By adopting an existing single-story air-welled terrace house, indoor environmental conditions and thermal performance were monitored and measured using HOBO U12 air temperature and humidity, the HOBO U12 anemometer, and the Delta Ohm HD32.3 Wet Bulb Globe Temperature meter for a six-month duration. The results show that the air temperature of the air well ranged from 27.48 °C to 30.92 °C, with a mean relative humidity of 72.67% to 79.25%. The mean air temperature for a test room (single-sided ventilation room) ranged from 28.04 °C to 30.92 °C, with a relative humidity of 70.16% to 76.00%. These empirical findings are of importance, offering novel policy insights and suggestions. Since the minimum provision of 10% openings has been revealed to be less effective to provide desirable thermal performance and comfort, mandatory compliance with and the necessity of the bylaw requirement should be revisited.


2021 ◽  
pp. 1420326X2110160
Author(s):  
Kai Yip Lee ◽  
Cheuk Ming Mak

This study investigated effects of incident wind angles on wind velocity distributions in wakes of two generic building configurations, namely, ‘T’- and ‘+’-shaped, and the air pressure distributions along their leeward walls by using computational fluid dynamics simulations. Results show that when the wind approaches laterally (90°) (vs. when the wind is direct (0°)), the downwind length and maximum bilateral width of the low-wind velocity zone in the wake of ‘T’-shaped building decrease by 11.5% and 37.9%, respectively. When the incident wind is oblique (45°) (vs. when it is direct), the length and width of this low-wind velocity zone in the wake of ‘+’-shaped building decrease by 15.0% and 30.9%, respectively. Furthermore, results show that the air pressure on the leeward walls of the ‘T’- and ‘+’-shaped buildings gradually decreases along with the building height. The resulting low-wind conditions on upper floors of buildings reduce the fresh air intake of their leeward units utilizing natural ventilation. It is particularly apparent in the case of direct approaching wind. Thus, the appropriate selection of building configurations and their orientations allows for the most effective use of wind to enhance ventilation in indoor and urban environments.


2022 ◽  
pp. 1420326X2110564
Author(s):  
Chuanmin Tai ◽  
Guansan Tian ◽  
Wenjun Lei

Condensation is a major issue in the safe operation of utility tunnels. To address the condensation problem, the indoor air temperature, relative humidity (RH) and surface temperature in an urban utility tunnel in Jining were continuously measured, and the condensation conditions were surveyed and analysed. The results indicated that under natural ventilation conditions, the air temperature in the comprehensive cabin varied from 23.4°C to 24.5°C, the RH fluctuated between 86.4% and 95.3%, and the corresponding air dew point temperature (DPT) remained in the range of 22.2°C–22.9°C. The surface temperature of the water supply pipeline ranged from 17.8°C to 18.5°C, which was far lower than the DPT in the tunnel, resulting in serious condensation. A water supply pipeline with an anti-condensation design was developed based on environmental test data. A 25-mm-thick rubber plastic sponge insulation layer was used to thermally insulate the water supply pipeline, preventing further dew condensation. Furthermore, mechanical ventilation had little effect on reducing the RH in the tunnel and may actually cause dew condensation; therefore, a ventilation control mode was proposed in this study. These results are expected to provide basic data for further research and reference for the safe management of utility tunnels.


2011 ◽  
Vol 374-377 ◽  
pp. 268-272
Author(s):  
Hai Yun Wang ◽  
Jing Shi

In this essay, the cooling method design was discussed from the perspective of architecture design using passive design based on the climate and geological environment of Shenzhen city. It concluded that shading and natural ventilation should be the major cooling method for this area, and design recommendations were put forward based on analysis from the perspective of plan layout, shape design, space form and detailed construction design.


Author(s):  
D.V. Tarasevych ◽  
◽  
O.V. Bogdan ◽  

When choosing architectural and planning solutions, such climatic factors as air temperature and humidity, having scalar quantities, as well as solar radiation, wind and precipitation having vector characteristics, must be taken into account. The calculated climatic parameters for the design of building enclosing structures, heat loss calculations and heat supply regulation are provided in the current documentation on norms and standards. The practical exploitation of various buildings demonstrates that in terms of initial climatic data, the choice of design parameters is not always efficiently justified; hence, the influence of the environment on the heating regime of the structures is insufficient in the estimations and sometimes erroneous. The wind is one of such climatic parameters. Its velocity and repeatability impact the heat exchange of the building structure with the environment as well as the alteration in temperature regime. The wind current towards the building creates additional pressure on the facade of the construction from the wind side direction. This leads, firstly, to air infiltration via the enclosing structures, and secondly, to the rise of heat exchange from the outer surface of the wall on the windward side. Based on estimated and analytical research, the values of the change in wind velocity depending on the altitude were analyzed, and its influence on the heat loss during heating of multi-storey buildings was assessed. The alterations in the wind velocity depending on the altitude were analyzed in the conditions of dense (urban) and broad construction. Besides, the authors presented the dependence of the convective component of the heat transfer coefficient of the outer surface of the structure on the values of the wind velocity. Based on the performed and presented calculations, it can be noticed that the heat transfer of the external structure will be much higher for multi-storey buildings than for mid-rise constructions. Thus, the convective component of the heat transfer coefficient of the outer surface rises by 36 % when the wind velocity increases from 5 m/s to 7 m/s. If not taking into consideration this dependence in the design, it can significantly influence the estimation of heat loss and energy efficiency of buildings, especially when it is about the increased percentage of facades glazing. The authors of the article assessed the heat loss for heating the windward and leeward facades at average values of the outside air temperature during the heating season in Ukraine. Hence, for constructions higher than 70 m with a calculated wind velocity of 5 m/s, heat losses increase from 10 % to 19 %. Such great difference in heat loss between the windward and leeward walls of the building requires increased thermal protection from the prevailing winter winds. Therefore, when designing multi-storey buildings, it is necessary to take into account changes in wind velocity according to the altitude. The obtained results can be useful both for choosing architectural and planning solutions, like the materials for external enclosing structures and for the objective assessment of the wind protection degree of individual buildings and territories.


2007 ◽  
Vol 580 ◽  
pp. 3-29 ◽  
Author(s):  
J. M. HOLFORD ◽  
A. W. WOODS

In this paper we examine the role of thermal mass in buffering the interior temperature of a naturally ventilated building from the diurnal fluctuations in the environment. First, we show that the effective thermal mass which is in good thermal contact with the air is limited by the diffusion distance into the thermal mass over one diurnal temperature cycle. We also show that this effective thermal mass may be modelled as an isothermal mass. Temperature fluctuations in the effective thermal mass are attenuated and phase-shifted from those of the interior air, and therefore heat is exchanged with the interior air. The evolution of the interior air temperature is then controlled by the relative magnitudes of (i) the time for the heat exchange between the effective thermal mass and the air; (ii) the time for the natural ventilation to replace the air in the space with air from the environment; and (iii) the period of the diurnal oscillations of the environment. Through analysis and numerical solution of the governing equations, we characterize a number of different limiting cases. If the ventilation rate is very small, then the thermal mass buffers the interior air temperature from fluctuations in the environment, creating a near-isothermal interior. If the ventilation rate increases, so that there are many air changes over the course of a day, but if there is little heat exchange between the thermal mass and interior air, then the interior air temperature locks on to the environment temperature. If there is rapid thermal equilibration of the thermal mass and interior air, and a high ventilation rate, then both the thermal mass and the interior air temperatures lock on to the environment temperature. However, in many buildings, the more usual case is that in which the time for thermal equilibration is comparable to the period of diurnal fluctuations, and in which ventilation rates are moderate. In this case, the fluctuations of the temperature of the thermal mass lag those of the interior air, which in turn lag those of the environment. We consider the implications of these results for the use of thermal mass in naturally ventilated buildings.


Author(s):  
Devendra Dandotiya ◽  
Nitin D. Banker

The power output of a gas turbine plant decreases with the increase in ambient temperature. Moreover, the ambient temperature fluctuates about 15–20°C in a day. Hence, cooling of intake air makes a noticeable improvement to the gas turbine performance. In this regard, various active cooling techniques such as vapor compression refrigeration, vapor absorption refrigeration, vapor adsorption refrigeration and evaporative cooling are applied for the cooling of intake air. This paper presents a new passive cooling technique where the intake air temperature is reduced by incorporating phase change material (PCM) based heat exchanger parallel to conventional air intake line. During the daytime, the air is passed through the PCM which has melting temperature lower than the peak ambient temperature. This will reduce the ambient air temperature before taking to the compressor. Once the PCM melts completely, the required ambient air would be drawn from the ambient through conventional air intake arrangement. During the night, when there is lower ambient temperature, PCM converts from liquid to solid. The selected PCM has a melting temperature less than the peak ambient temperature and higher than the minimum ambient temperature. It is observed from the numerical modeling of the PCM that about four hours are required for the melting of PCM and within this time, the intake air can also be cooled by 5°C. The thermodynamic analysis of the results showed about 5.2% and 5.2% improvement in net power output and thermal efficiency, respectively for four hours at an ambient temperature of 45°C.


1915 ◽  
Vol 35 ◽  
pp. 203-216
Author(s):  
R. C. Mossman

In the course of a large inquiry on the inter-relations between the meteorological conditions in Antarctica and the Southern Ocean, on the one hand, and those prevailing in the southern continents, more especially South America, on the other, there has come to light an interesting see-saw between the barometric pressure, air temperature, and wind velocity in the Weddell and the Boss Seas. The above inquiry, which I hope to lay before this Society shortly, refers to the eight-year period 1902–09; and since the present paper deals with the years 1902, 1903, 1911, and 1912, I have thought it better to make it the subject of a separate communication. The positions of these stations and others where observations have been made are shown on the accompanying map, for which I am indebted to Dr H. R. Mill. The figures within the rings give the number of years covered by the records at the various places.