A method for rapid detection and evaluation of position errors of patterns of small holes on complex curved and freeform surfaces

Author(s):  
Xiaomei Chen ◽  
Andrew Longstaff ◽  
Simon Parkinson ◽  
Alan Myers
2014 ◽  
Vol 53 (10) ◽  
pp. 2246
Author(s):  
Xiaomei Chen ◽  
Andrew Longstaff ◽  
Simon Fletcher ◽  
Alan Myers

Author(s):  
L. Andrew Staehelin

Freeze-etched membranes usually appear as relatively smooth surfaces covered with numerous small particles and a few small holes (Fig. 1). In 1966 Branton (1“) suggested that these surfaces represent split inner mem¬brane faces and not true external membrane surfaces. His theory has now gained wide acceptance partly due to new information obtained from double replicas of freeze-cleaved specimens (2,3) and from freeze-etch experi¬ments with surface labeled membranes (4). While theses studies have fur¬ther substantiated the basic idea of membrane splitting and have shown clearly which membrane faces are complementary to each other, they have left the question open, why the replicated membrane faces usually exhibit con¬siderably fewer holes than particles. According to Branton's theory the number of holes should on the average equal the number of particles. The absence of these holes can be explained in either of two ways: a) it is possible that no holes are formed during the cleaving process e.g. due to plastic deformation (5); b) holes may arise during the cleaving process but remain undetected because of inadequate replication and microscope techniques.


Author(s):  
O. E. Bradfute

Electron microscopy is frequently used in preliminary diagnosis of plant virus diseases by surveying negatively stained preparations of crude extracts of leaf samples. A major limitation of this method is the time required to survey grids when the concentration of virus particles (VPs) is low. A rapid survey of grids for VPs is reported here; the method employs a low magnification, out-of-focus Search Mode similar to that used for low dose electron microscopy of radiation sensitive specimens. A higher magnification, in-focus Confirm Mode is used to photograph or confirm the detection of VPs. Setting up the Search Mode by obtaining an out-of-focus image of the specimen in diffraction (K. H. Downing and W. Chiu, private communications) and pre-aligning the image in Search Mode with the image in Confirm Mode facilitates rapid switching between Modes.


Author(s):  
C.D. Humphrey ◽  
T.L. Cromeans ◽  
E.H. Cook ◽  
D.W. Bradley

There is a variety of methods available for the rapid detection and identification of viruses by electron microscopy as described in several reviews. The predominant techniques are classified as direct electron microscopy (DEM), immune electron microscopy (IEM), liquid phase immune electron microscopy (LPIEM) and solid phase immune electron microscopy (SPIEM). Each technique has inherent strengths and weaknesses. However, in recent years, the most progress for identifying viruses has been realized by the utilization of SPIEM.


2012 ◽  
Vol 6 (1) ◽  
pp. 11-13
Author(s):  
Sushmita Roy ◽  
S.M. Shamsuzzaman ◽  
K.Z. Mamun

Rotavirus is one of the leading causes of pediatric diarrhea globally. Accurate and rapid diagnosis of Rotavirus diarrhea should reduce unnecessary use of antibiotics and ultimately reduce drug resistance. Study was designed for rapid diagnosis of Rotavirus antigen in stool sample by ICT (Immunochromatographic test) as well as to observe the seasonal variation of rotavirus infection. This cross sectional study was carried out in the department of Microbiology, Dhaka Medical College from January 2011 to December 2011. Eighty stool samples were collected from Dhaka Shishu Hospital and Dhaka Medical College Hospital. All samples were tested for rotavirus antigen by ICT. Among 80 patients, 42 (52.5%) samples were positive for rotavirus antigen. Among these 42 positive samples, 30 (71.43%) were from 0-12 months of age group, 10 (23.81%) from 13 to 24 months of age group and rest 2 (4.76%) from 25 to 36 months of age group. Rotavirus Ag was detected in stool samples from January to April and another peak episode from October to December. Considering the importance of Rotavirus associated diarrhea, rapid detection of Rotavirus infection in human is substantially needed and should be routinely practiced.DOI: http://dx.doi.org/10.3329/bjmm.v6i1.19354 Bangladesh J Med Microbiol 2012; 06(01): 11-13


2014 ◽  
Vol 17 (2) ◽  
pp. 367-369 ◽  
Author(s):  
K. Rypula ◽  
A. Kumala ◽  
P. Lis ◽  
K. Niemczuk ◽  
K. Płoneczka-Janeczko ◽  
...  

Abstract The study was carried out in seven reproductive herds of pigs. In three of them reproductive disorders were observed. Three herds consisted of 10-50 and four consisted of 120-500 adult sows and they were called small and medium, respectively. Fifty-seven adult sows were randomly selected from herds. Serum samples were tested using the complement fixation test and swabs from both eyes and from the vaginal vestibule were examined using real-time PCR. All serum samples were negative. Infected sows were present in each of the study herds. In total, there were 28 positive samples (53%, 28/48) in real-time PCR in sows with reproductive disorders and 35 (53%, 35/66) in sows selected from herds without problems in reproduction. One isolate proved to be Chlamydophila pecorum, whereas all the remaining were Chamydia suis


Sign in / Sign up

Export Citation Format

Share Document