Adjusting wastewater treatment effluent standards to protect the receiving waters: the case of low-flow rivers in central Spain

2020 ◽  
Vol 79 (19) ◽  
Author(s):  
Antonio Bolinches ◽  
Lucia De Stefano ◽  
Javier Paredes-Arquiola
1993 ◽  
Vol 27 (12) ◽  
pp. 205-208
Author(s):  
Dirk-Th Kollatsch

For upgrading the urban drainage system (UDS) the reduction of pollution impacts is the priority task concerning the environmental protection of the receiving waters. With simulation models the interactions between surface, sewer systems, overflow structures and treatment facilities within the UDS can be shown. Models to simulate the pollutant impacts, transport and the effects on the receiving waters are available. In a first step a pollutant transport model of sewer systems and a model to simulate the wastewater treatment processes are connected. With these models the efficiency of upgrading measures can be checked in all parts of urban drainage systems.


1998 ◽  
Vol 38 (3) ◽  
pp. 127-134
Author(s):  
Jaap H. J. M. van der Graaf ◽  
Arjen F. van Nieuwenhuijzen

As yet, filtration of wastewater treatment effluent has not been practised in the Netherlands. The main objections were the expected high costs. In order to gain practical experience an investigation programme studied the applicability and optimization of effluent filtration. Especially multi-layer filtration with the addition of ironchloride seemed to be very effective. Very low concentrations of suspended solids and phosphorus were achieved, even at high filtration rates (up to 30 m/h). This leads to an impressive reduction of expected costs, down to Dfl. 0.02/m3 (treated water).


2000 ◽  
Vol 41 (9) ◽  
pp. 89-95 ◽  
Author(s):  
G. Ladiges ◽  
N-P. Bertram ◽  
R. Otterpohl

The Hamburger Stadtentwässerung (HSE) is planning to take on a further approximately 250,000 PE in addition to the 1.85 m PE already served by its combined wastewater treatment plants at Köhlbrandhöft/Dradenau. To cope with the increased load, a concept for the extension of the plants had to be developed. Various concepts were compared and evaluated using a dynamic computer simulation. The very wide-ranging simulation study showed that the required effluent standards can still be achieved after the volume of the sludge liquor storage capacity has been increased. As many concepts had been assessed in detail, the final solution chosen was considerably less expensive than if the wastewater treatment plants had been extended in a traditional manner.


2021 ◽  
Author(s):  
Adamo R. Petosa ◽  
Monica Nowierski ◽  
Viviane Yargeau

Abstract Bioanalytical tools, namely in vitro bioassays, can be employed in tandem with chemical analyses to assess the efficacy of wastewater treatment and the potential for adverse effects from the discharges of wastewater into receiving waters. In the present study, samples of untreated wastewater (i.e. influent) and treated wastewater (i.e. effluent) were collected from two wastewater treatment plants and a wastewater treatment lagoon serving municipalities in southern Ontario, Canada. In addition, grab samples of surface water were collected downstream of the lagoon discharge. After solid phase extraction (SPE) using ion-exchange columns for basic/neutral and acidic compounds, respectively, the extracts were analyzed for a suite of 16 indicator compounds. The two SPE extracts were combined for analysis of biological responses in four in vitro cell-based bioassays. The concentrations of several indicator compounds, including the estrogens, 17β-estradiol and 17α-ethinylestradiol, were below the limits of detection. However, androstenedione and estrone were detected in several influent samples. The concentrations of these steroid hormones and some of the other indicator compounds declined during treatment but acesulfame K, carbamazepine, trimethoprim and DEET persisted in the effluent. The MTS- CellTiter 96® AQueous One Solution Cell Proliferation Assay (MTS) indicated that cell viability was not affected by exposure to the extracts. The Qiagen Nuclear Receptors 10-Pathway Reporter Array indicated that several cellular pathways were upregulated, with the greatest upregulation observed with the estrogen receptor (i.e. induction ratios 12 to 47) and the liver X receptor (i.e. induction ratios 10 to 45). The ERα CALUX assay indicated that estrogenic activity was lower in effluents compared to influents, with the greatest estrogenic activity observed for grab samples of influent from the lagoon (i.e. 56-215 ng L-1 17β-estradiol equivalents). Finally, the results of the Nrf2 Luciferase Luminescence Assay indicated a lower oxidative stress in the effluent samples. Overall, the present study demonstrates that chemical analyses are limited in their ability to predict or explain reductions in the toxicity of treated wastewater. There are thus advantages to using a combination of chemical analyses and in vitro bioassays to monitor the treatment efficiency of wastewater treatment plants and to predict the potential impacts of wastewater discharges into receiving waters.


Water ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2618
Author(s):  
Jae Heon Cho ◽  
Jong Ho Lee

In traditional waste load allocation (WLA) decision making, water quality-related constraints must be satisfied. Fuzzy models, however, can be useful for policy makers to make the most reasonable decisions in an ambiguous environment, considering various surrounding environments. We developed a fuzzy WLA model that optimizes the satisfaction level by using fuzzy membership functions and minimizes the water quality management cost for policy decision makers considering given environmental and socioeconomic conditions. The fuzzy optimization problem was formulated using a max–min operator. The fuzzy WLA model was applied to the Yeongsan River basin, which is located in the southwestern part of the Korean Peninsula and Korean TMDLs were applied. The results of the fuzzy model show that the pollutant load reduction should be increased in the Gwangju 1 and Gwangju 2 wastewater treatment plants (WWTPs) and in subcatchments with high pollutant load. In particular, it is necessary to perform advanced wastewater treatment to decrease the load of 932 kg ultimate biochemical oxygen demand (BODu)/day in the large-capacity Gwangju 1 WWTP and reduce the BODu emission concentration from 4.3 to 2.7 mg/L during the low-flow season. The satisfaction level of the fuzzy model is a relatively high at 0.81.


2000 ◽  
Vol 41 (9) ◽  
pp. 7-14
Author(s):  
A. Jobbágy ◽  
B. Literáthy ◽  
F. Farkas ◽  
Gy. Garai ◽  
Gy. Kovács

The treated effluent of the Southpest Wastewater Treatment Plant is discharged into a small, low-flow branch of the Danube susceptible to eutrophication. The first, high-load activated sludge system with a hydraulic retention time of 2.5 hrs in the aerated basins, was installed here in 1966. The paper presents the evolution of the technology by illustrating the effects of the different changes carried out since 1991. Reconfiguration of the existing activated sludge basins connected originally in parallel into an arrangement of tanks in series increased the settleability of the sludge as well as the efficiency of COD removal significantly. Introduction of an anaerobic zone preceding the aerated basins facilitated biological excess phosphorus removal with a consequent release in the thickener and digester. Introducing lime addition into the recycled sludge processing wastes significantly improved the performance of the system. However, since there had been no provision built for eliminating the nitrate content of the recycled sludge, efficiency of phosphorus removal proved to be dependent on the eventually occurring nitrification. In order to achieve both an effective nitrogen and phosphorus removal the current technology established in 1999 applies a nitrification and a denitrification filter following the activated sludge unit and uses precipitation for phosphorus removal.


2019 ◽  
Vol 9 (12) ◽  
pp. 2500 ◽  
Author(s):  
Shun-hwa Lee ◽  
Yeon-jung Cho ◽  
Miran Lee ◽  
Byung-Dae Lee

We surveyed the variation in perfluorinated compound (PFC) concentrations entering urban wastewater treatment plants and then designed an optimal PFCs treatment method based on a pilot test. The PFCs influent concentration was found to be affected by the types of industries and operating rate. The concentration of PFCs in the wastewater treatment effluent was slightly lower than that of the influent. Thus, PFCs had not been adequately removed by the existing biological treatments. The pilot test results showed that about 10% of PFCs was removed by coagulation and precipitation, and the ozone and chlorine test showed that few, if any, PFCs were removed regardless of the oxidant dose. The activated carbon adsorption test showed that the removal significantly increased with empty bed contact time, with about a 60% removal in five minutes and over 90% removal in over 15 minutes. Therefore, a more stable and higher PFCs removal would result from continuous oxidation processes, such as ozone and adsorption processes involving activated carbon, rather than a single biological treatment.


Sign in / Sign up

Export Citation Format

Share Document