scholarly journals Diabetes classification application with efficient missing and outliers data handling algorithms

Author(s):  
Hanaa Torkey ◽  
Elhossiny Ibrahim ◽  
EZZ El-Din Hemdan ◽  
Ayman El-Sayed ◽  
Marwa A. Shouman

AbstractCommunication between sensors spread everywhere in healthcare systems may cause some missing in the transferred features. Repairing the data problems of sensing devices by artificial intelligence technologies have facilitated the Medical Internet of Things (MIoT) and its emerging applications in Healthcare. MIoT has great potential to affect the patient's life. Data collected from smart wearable devices size dramatically increases with data collected from millions of patients who are suffering from diseases such as diabetes. However, sensors or human errors lead to missing some values of the data. The major challenge of this problem is how to predict this value to maintain the data analysis model performance within a good range. In this paper, a complete healthcare system for diabetics has been used, as well as two new algorithms are developed to handle the crucial problem of missed data from MIoT wearable sensors. The proposed work is based on the integration of Random Forest, mean, class' mean, interquartile range (IQR), and Deep Learning to produce a clean and complete dataset. Which can enhance any machine learning model performance. Moreover, the outliers repair technique is proposed based on dataset class detection, then repair it by Deep Learning (DL). The final model accuracy with the two steps of imputation and outliers repair is 97.41% and 99.71% Area Under Curve (AUC). The used healthcare system is a web-based diabetes classification application using flask to be used in hospitals and healthcare centers for the patient diagnosed with an effective fashion.

2020 ◽  
Vol 24 (7) ◽  
pp. 1261-1265
Author(s):  
E.P. Idoga ◽  
A.I. Adamu

In the field of health care management, smart wearable devices and its supporting technologies have tremendously made a name all around the globe. Smart watches and other sensor trackers are practically being used by various people and its usage has shown to be accompanied with lots  of benefits. This technology was envisaged to play a vital role in the healthcare needs of people; especially with applications in the healthcare sector. The objective of this study, therefore, is to evaluate the technological impact of wearable sensors in human health and fitness (HHF). A web based survey was used for data collection for the period of one month. Emails were sent to registered members of a particular gym who uses any of the smart wearable sensors in keeping fit. The study findings indicate that among the smart wearable devices examined, smart wristwatches (45.6%) appears to be the most commonly used wearable sensor device followed by smart wrist bands (34.7%), smart textiles (10.7%) and smart rings (9.1%). This signifies that a large number of people can effortlessly use SWSs and devices and are optimistic about its support in their daily  healthcare/fitness needs. Users are positive on the technological prospects of SWSs and devices; although there is a gap between personal  motivation to use wearable devices and trust in the confidentiality and privacy of data generated. Keywords: Devices, Health, Fitness, Wearable, Sensors


Processes ◽  
2020 ◽  
Vol 8 (5) ◽  
pp. 518
Author(s):  
Kexin Bi ◽  
Tong Qiu ◽  
Yizhen Huang

During the development of innovative products, consumer preferences are the essential factors for yogurt producers to improve their market share. A high-performance prediction method will be beneficial to understand the intrinsic relevance between preferences and sensory attributes. In this study, a novel deep learning method is proposed that uses an autoencoder to extract product features from the sensory attributes scored by experts, and the sensory features acquired are regressed on consumer preferences with support vector machine analysis. Model performance analysis, hedonic contour mapping, and feature clustering were implemented to validate the overall learning process. The results showed that the deep learning model can vouch an acceptable level of accuracy, and the hedonic mapping reflected could supply a great help for producers’ product design or modification. Finally, hierarchical clustering analysis revealed that for all three brands of yogurts, low temperature (4 °C) storage for no more than 4 weeks can promise the highest consumer preferences.


2017 ◽  
Vol 4 (2) ◽  
pp. 63-81
Author(s):  
Stefanus Oliver ◽  
Abdullah Muzi Marpaung ◽  
Maulahikmah Galinium

Food sensory analysis is the terms from the field of Food Technology that has a meaning which means sensory evaluation of food that is conducted by the food sensory evaluators. Currently, food sensory analysis is conductedmanually. It can caus e human errors and consume much ti me. The objective of this research is to build a web based application that is specific for food sensory analysis using PHP programming language. This research followsfour first steps of waterfall software engineering mod el which are user requirements ana lysis (user software and requirements analysis), system design (activity, use cases, architecture, and entity relationship diagram),implementation (software development), and testing (software unit, functionality, validit y, and user acceptance testing). T he software result is well built. It is also acceptable for users and all functionality features can run well after going through those four software testing. The existence of the software brings easiness to deal with the manual food sensory analysis exper iment. It is considered also for the future it has business value by having open source and premium features.


Micromachines ◽  
2021 ◽  
Vol 12 (4) ◽  
pp. 352
Author(s):  
Ruonan Li ◽  
Xuelian Wei ◽  
Jiahui Xu ◽  
Junhuan Chen ◽  
Bin Li ◽  
...  

Accurate monitoring of motion and sleep states is critical for human health assessment, especially for a healthy life, early diagnosis of diseases, and medical care. In this work, a smart wearable sensor (SWS) based on a dual-channel triboelectric nanogenerator was presented for a real-time health monitoring system. The SWS can be worn on wrists, ankles, shoes, or other parts of the body and cloth, converting mechanical triggers into electrical output. By analyzing these signals, the SWS can precisely and constantly monitor and distinguish various motion states, including stepping, walking, running, and jumping. Based on the SWS, a fall-down alarm system and a sleep quality assessment system were constructed to provide personal healthcare monitoring and alert family members or doctors via communication devices. It is important for the healthy growth of the young and special patient groups, as well as for the health monitoring and medical care of the elderly and recovered patients. This work aimed to broaden the paths for remote biological movement status analysis and provide diversified perspectives for true-time and long-term health monitoring, simultaneously.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Young-Gon Kim ◽  
Sungchul Kim ◽  
Cristina Eunbee Cho ◽  
In Hye Song ◽  
Hee Jin Lee ◽  
...  

AbstractFast and accurate confirmation of metastasis on the frozen tissue section of intraoperative sentinel lymph node biopsy is an essential tool for critical surgical decisions. However, accurate diagnosis by pathologists is difficult within the time limitations. Training a robust and accurate deep learning model is also difficult owing to the limited number of frozen datasets with high quality labels. To overcome these issues, we validated the effectiveness of transfer learning from CAMELYON16 to improve performance of the convolutional neural network (CNN)-based classification model on our frozen dataset (N = 297) from Asan Medical Center (AMC). Among the 297 whole slide images (WSIs), 157 and 40 WSIs were used to train deep learning models with different dataset ratios at 2, 4, 8, 20, 40, and 100%. The remaining, i.e., 100 WSIs, were used to validate model performance in terms of patch- and slide-level classification. An additional 228 WSIs from Seoul National University Bundang Hospital (SNUBH) were used as an external validation. Three initial weights, i.e., scratch-based (random initialization), ImageNet-based, and CAMELYON16-based models were used to validate their effectiveness in external validation. In the patch-level classification results on the AMC dataset, CAMELYON16-based models trained with a small dataset (up to 40%, i.e., 62 WSIs) showed a significantly higher area under the curve (AUC) of 0.929 than those of the scratch- and ImageNet-based models at 0.897 and 0.919, respectively, while CAMELYON16-based and ImageNet-based models trained with 100% of the training dataset showed comparable AUCs at 0.944 and 0.943, respectively. For the external validation, CAMELYON16-based models showed higher AUCs than those of the scratch- and ImageNet-based models. Model performance for slide feasibility of the transfer learning to enhance model performance was validated in the case of frozen section datasets with limited numbers.


2021 ◽  
Author(s):  
Birgid Schömig-Markiefka ◽  
Alexey Pryalukhin ◽  
Wolfgang Hulla ◽  
Andrey Bychkov ◽  
Junya Fukuoka ◽  
...  

AbstractDigital pathology provides a possibility for computational analysis of histological slides and automatization of routine pathological tasks. Histological slides are very heterogeneous concerning staining, sections’ thickness, and artifacts arising during tissue processing, cutting, staining, and digitization. In this study, we digitally reproduce major types of artifacts. Using six datasets from four different institutions digitized by different scanner systems, we systematically explore artifacts’ influence on the accuracy of the pre-trained, validated, deep learning-based model for prostate cancer detection in histological slides. We provide evidence that any histological artifact dependent on severity can lead to a substantial loss in model performance. Strategies for the prevention of diagnostic model accuracy losses in the context of artifacts are warranted. Stress-testing of diagnostic models using synthetically generated artifacts might be an essential step during clinical validation of deep learning-based algorithms.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shota Ichikawa ◽  
Misaki Hamada ◽  
Hiroyuki Sugimori

AbstractBody weight is an indispensable parameter for determination of contrast medium dose, appropriate drug dosing, or management of radiation dose. However, we cannot always determine the accurate patient body weight at the time of computed tomography (CT) scanning, especially in emergency care. Time-efficient methods to estimate body weight with high accuracy before diagnostic CT scans currently do not exist. In this study, on the basis of 1831 chest and 519 abdominal CT scout images with the corresponding body weights, we developed and evaluated deep-learning models capable of automatically predicting body weight from CT scout images. In the model performance assessment, there were strong correlations between the actual and predicted body weights in both chest (ρ = 0.947, p < 0.001) and abdominal datasets (ρ = 0.869, p < 0.001). The mean absolute errors were 2.75 kg and 4.77 kg for the chest and abdominal datasets, respectively. Our proposed method with deep learning is useful for estimating body weights from CT scout images with clinically acceptable accuracy and potentially could be useful for determining the contrast medium dose and CT dose management in adult patients with unknown body weight.


2021 ◽  
Vol 11 (4) ◽  
pp. 290
Author(s):  
Luca Pasquini ◽  
Antonio Napolitano ◽  
Emanuela Tagliente ◽  
Francesco Dellepiane ◽  
Martina Lucignani ◽  
...  

Isocitrate dehydrogenase (IDH) mutant and wildtype glioblastoma multiforme (GBM) often show overlapping features on magnetic resonance imaging (MRI), representing a diagnostic challenge. Deep learning showed promising results for IDH identification in mixed low/high grade glioma populations; however, a GBM-specific model is still lacking in the literature. Our aim was to develop a GBM-tailored deep-learning model for IDH prediction by applying convoluted neural networks (CNN) on multiparametric MRI. We selected 100 adult patients with pathologically demonstrated WHO grade IV gliomas and IDH testing. MRI sequences included: MPRAGE, T1, T2, FLAIR, rCBV and ADC. The model consisted of a 4-block 2D CNN, applied to each MRI sequence. Probability of IDH mutation was obtained from the last dense layer of a softmax activation function. Model performance was evaluated in the test cohort considering categorical cross-entropy loss (CCEL) and accuracy. Calculated performance was: rCBV (accuracy 83%, CCEL 0.64), T1 (accuracy 77%, CCEL 1.4), FLAIR (accuracy 77%, CCEL 1.98), T2 (accuracy 67%, CCEL 2.41), MPRAGE (accuracy 66%, CCEL 2.55). Lower performance was achieved on ADC maps. We present a GBM-specific deep-learning model for IDH mutation prediction, with a maximal accuracy of 83% on rCBV maps. Highest predictivity achieved on perfusion images possibly reflects the known link between IDH and neoangiogenesis through the hypoxia inducible factor.


Neurosurgery ◽  
2020 ◽  
Vol 67 (Supplement_1) ◽  
Author(s):  
Syed M Adil ◽  
Lefko T Charalambous ◽  
Kelly R Murphy ◽  
Shervin Rahimpour ◽  
Stephen C Harward ◽  
...  

Abstract INTRODUCTION Opioid misuse persists as a public health crisis affecting approximately one in four Americans.1 Spinal cord stimulation (SCS) is a neuromodulation strategy to treat chronic pain, with one goal being decreased opioid consumption. Accurate prognostication about SCS success is key in optimizing surgical decision making for both physicians and patients. Deep learning, using neural network models such as the multilayer perceptron (MLP), enables accurate prediction of non-linear patterns and has widespread applications in healthcare. METHODS The IBM MarketScan® (IBM) database was queried for all patients ≥ 18 years old undergoing SCS from January 2010 to December 2015. Patients were categorized into opioid dose groups as follows: No Use, ≤ 20 morphine milligram equivalents (MME), 20–50 MME, 50–90 MME, and &gt;90 MME. We defined “opiate weaning” as moving into a lower opioid dose group (or remaining in the No Use group) during the 12 months following permanent SCS implantation. After pre-processing, there were 62 predictors spanning demographics, comorbidities, and pain medication history. We compared an MLP with four hidden layers to the LR model with L1 regularization. Model performance was assessed using area under the receiver operating characteristic curve (AUC) with 5-fold nested cross-validation. RESULTS Ultimately, 6,124 patients were included, of which 77% had used opioids for &gt;90 days within the 1-year pre-SCS and 72% had used &gt;5 types of medications during the 90 days prior to SCS. The mean age was 56 ± 13 years old. Collectively, 2,037 (33%) patients experienced opiate weaning. The AUC was 0.74 for the MLP and 0.73 for the LR model. CONCLUSION To our knowledge, we present the first use of deep learning to predict opioid weaning after SCS. Model performance was slightly better than regularized LR. Future efforts should focus on optimization of neural network architecture and hyperparameters to further improve model performance. Models should also be calibrated and externally validated on an independent dataset. Ultimately, such tools may assist both physicians and patients in predicting opioid dose reduction after SCS.


Sign in / Sign up

Export Citation Format

Share Document