The energy dissipation behaviors of magneto-sensitive polymer gel under cyclic shear loading

2015 ◽  
Vol 158 ◽  
pp. 406-408 ◽  
Author(s):  
Yangguang Xu ◽  
Taixiang Liu ◽  
Qiang Wan ◽  
Xinglong Gong ◽  
Shouhu Xuan
Buildings ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 41
Author(s):  
Moo-Won Hur ◽  
Yonghun Lee ◽  
Min-Jun Jeon ◽  
Sang-Hyun Lee

In this study, the Kagome truss damper, a metallic wire structures, was introduced and its mechanical properties were investigated through theoretical analyses and experimental tests. The yield strength of the Kagome damper is dependent on the geometric shape and diameter of the metallic wire. The Kagome damper has higher resistance to plastic buckling as well as lower anisotropy. Cyclic shear loading tests were conducted to investigate the energy dissipation capacity and stiffness/strength degradation by repeated loadings. The hysteretic properties obtained from the tests suggest that a modification of the ideal truss model with a hinged connection could be used to predict the yield strength and stiffness of the damper. For seismic retrofitting of a low-rise RC moment frame system, a wall-type Kagome damping system (WKDS) was proposed. The effectiveness of the proposed system was verified by conducting cyclic loading tests using a RC frame with/without the WKDS (story drift ratio limit 1.0%). The test results indicated that both the strength and stiffness of the RC frame increased to the target level and that its energy dissipation capacity was significantly enhanced. Nonlinear static and dynamic analyses were carried out to validate that the existing building structure can be effectively retrofitted using the proposed WKDS.


PCI Journal ◽  
1996 ◽  
Vol 41 (3) ◽  
pp. 64-80 ◽  
Author(s):  
Khaled A. Soudki ◽  
Jeffrey S. West ◽  
Sami H. Rizkalla ◽  
Bruce Blackett

2013 ◽  
Vol 12 (4) ◽  
pp. 1615-1638 ◽  
Author(s):  
Georgia D. Kremmyda ◽  
Yasin M. Fahjan ◽  
Spyros G. Tsoukantas

2018 ◽  
Vol 199 ◽  
pp. 09008
Author(s):  
Philipp Mahrenholtz ◽  
Jae-Yeol Cho ◽  
Ja-Min Park ◽  
Rolf Eligehausen

A critical performance aspect of FRP retrofitted concrete elements is the bonding of the FRP sheet to the concrete surface. In general, the performance is limited by the debonding of the loaded FRP sheets from the concrete surface. One method to delay debonding and enhance the capacity is the use of FRP anchors which interlock the FRP sheet to the concrete body. FRP anchors are made of rolled FRP fibres epoxied into in predrilled boreholes. There are a considerable number of studies on FRP strengthening methods available, and also FRP anchors attract more attention of the research community recently. However, to date FRP anchors were tested in a system together with the FRP sheet attached to the concrete, inhibiting the development of general design models. Moreover, the anchor behaviour was never tested for cyclic loads, though most applications are for seismic retrofitting schemes and cyclic shear loading generally results in reduced load capacity due to fatigue failure. To overcome the deficit in knowledge, shear tests on various FRP anchors were carried out. For these tests, FRP anchors were installed in concrete specimens on a separating steel section. The FRP anchor was then directly loaded to determine the capacity of the isolated component. This paper describes the testing approach and procedure. Details on the experimental results for static tests are presented and an outlook on seismic tests is given.


2015 ◽  
Vol 1125 ◽  
pp. 121-125 ◽  
Author(s):  
Muhammad A'imullah Abdullah ◽  
Mohammad Reza Arjmandi ◽  
Seyed Saeid Rahimian Koloor ◽  
King Jye Wong ◽  
Mohd Nasir Tamin

This paper provides quantitative description of interlaminar damage process in CFRP composite laminates under cyclic shear loading. Quasi-static end-notched flexural (ENF) test on 16-ply CFRP composite laminate beam, [0]16 and its complementary validated FE model provide the reference “no-interlaminar damage” condition. Two identical ENF samples were fatigue to 50000 cycles, but at different load amplitude of 90 and 180 N, respectively (Load ratio, R = 0.1) to induce selectively property degradation at the interface crack front region. Subsequent quasi-static ENF tests establish the characteristic of the interlaminar damage degradation. The residual peak load for the fatigued ENF samples is measured at 1048 and 914 N for the load amplitude of 90 and 180 N, respectively. Cyclic interlaminar shear damage is represented by a linear degradation of the residual critical energy release rate, GIIC with the accumulated damage. Reasonably close comparisons of the predicted residual load-displacement responses with measured curves serve to verify the suitability of the assumed bilinear traction-separation law for the cyclic cohesive zone model (CCZM) used.


2000 ◽  
Vol 1740 (1) ◽  
pp. 143-150 ◽  
Author(s):  
Erin P. Donovan ◽  
Imad L. Al-Qadi ◽  
Amara Loulizi

One of the critical components of the U.S. civil infrastructure, bridges, has rapidly deteriorated in the past two decades and is in need of maintenance and rehabilitation. Geosynthetics may have the potential to provide a long-term solution to some of the problems that are present in these bridges, mainly, chloride intrusion into bridge decks. When installed properly, geosynthetics can act as both a moisture barrier and a stress absorption layer. However, the tack coat application rate is critical, as an excessive amount can cause eventual slippage, whereas too little may result in debonding. A new geocomposite membrane that comprises a low-modulus polyvinyl chloride layer sandwiched between two layers of nonwoven geotextile has recently been introduced for use in highway systems for water impermeation and strain energy absorption. A laboratory testing program was conducted to determine the optimum asphalt binder tack coat application rate that needs to be applied in the field. To accomplish this, a fixture was designed to allow the application of cyclic shear loading at the geocomposite membrane interface when used as an interlayer simulating a concrete bridge deck overlaid with the geocomposite membrane and a hot-mix asphalt (HMA) overlay. The study concluded that 1.75 kg of PG 64-22 binder per m2 is an optimum value to achieve excellent bonding and minimum slippage potential. For the upper surface in contact with a wearing surface mix, a tack coat application rate of 1.5 kg/m2 may be used. When the geocomposite membrane was included between concrete and HMA, failure occurred after a much larger number of applied loading cycles than the number of loading cycles to failure when the geocomposite was absent. In addition, the slope of shear stress versus the number of loading cycles at failure was much greater when the geocomposite was absent.


2005 ◽  
Vol 21 (4) ◽  
pp. 1093-1112 ◽  
Author(s):  
Thomas T. C. Hsu ◽  
Mohamad Y. Mansour

A new Cyclic Softened Membrane Model (CSMM) was recently developed to predict the stiffness, ductility, and energy dissipation of reinforced concrete (RC) elements subjected to reversed cyclic shear. Using the nonlinear finite element analysis, we can integrate these responses of elements to predict the behavior of a whole structure, such as a low-rise shear wall, subjected to earthquake action. This study of CSMM summarizes systematically the effects of the two primary variables: the steel bar angle with respect to the direction of the applied principal stresses and the steel percentage. The results clearly show that RC structures under cyclic shear stresses could be designed to be very ductile, have large stiffness, and possess high energy-dissipation capacities (just like flexural-dominated elements), if the steel bars are properly oriented in the directions of principal stresses and if the steel percentages are kept within certain limits.


Sign in / Sign up

Export Citation Format

Share Document