Energy monitoring of high dose ion implantation in semiconductors via photocurrent measurement

2015 ◽  
Vol 55 (9-10) ◽  
pp. 1369-1372
Author(s):  
C. Eichenseer ◽  
G. Poeppel ◽  
T. Mikolajick
Author(s):  
N. Lewis ◽  
E. L. Hall ◽  
A. Mogro-Campero ◽  
R. P. Love

The formation of buried oxide structures in single crystal silicon by high-dose oxygen ion implantation has received considerable attention recently for applications in advanced electronic device fabrication. This process is performed in a vacuum, and under the proper implantation conditions results in a silicon-on-insulator (SOI) structure with a top single crystal silicon layer on an amorphous silicon dioxide layer. The top Si layer has the same orientation as the silicon substrate. The quality of the outermost portion of the Si top layer is important in device fabrication since it either can be used directly to build devices, or epitaxial Si may be grown on this layer. Therefore, careful characterization of the results of the ion implantation process is essential.


Author(s):  
A. De Veirman ◽  
J. Van Landuyt ◽  
K.J. Reeson ◽  
R. Gwilliam ◽  
C. Jeynes ◽  
...  

In analogy to the formation of SIMOX (Separation by IMplanted OXygen) material which is presently the most promising silicon-on-insulator technology, high-dose ion implantation of cobalt in silicon is used to synthesise buried CoSi2 layers. So far, for high-dose ion implantation of Co in Si, only formation of CoSi2 is reported. In this paper it will be shown that CoSi inclusions occur when the stoichiometric Co concentration is exceeded at the peak of the Co distribution. 350 keV Co+ ions are implanted into (001) Si wafers to doses of 2, 4 and 7×l017 per cm2. During the implantation the wafer is kept at ≈ 550°C, using beam heating. The subsequent annealing treatment was performed in a conventional nitrogen flow furnace at 1000°C for 5 to 30 minutes (FA) or in a dual graphite strip annealer where isochronal 5s anneals at temperatures between 800°C and 1200°C (RTA) were performed. The implanted samples have been studied by means of Rutherford Backscattering Spectroscopy (RBS) and cross-section Transmission Electron Microscopy (XTEM).


1983 ◽  
Vol 27 ◽  
Author(s):  
J.C. Soares ◽  
A.A. Melo ◽  
M.F. DA Silva ◽  
E.J. Alves ◽  
K. Freitag ◽  
...  

ABSTRACTLow and high dose hafnium imolanted beryllium samoles have been prepared at room temperature by ion implantation of beryllium commercial foils and single crystals. These samples have been studied before and after annealing with the time differential perturbed angular correlation method (TDPAC) and with Rutherford backscattering and channeling techniques. A new metastable system has been discovered in TDPAC-measurements in a low dose hafnium implanted beryllium foil annealed at 500°C. Channeling measurements show that the hafnium atoms after annealing, are in the regular tetrahedral sites but dislocated from the previous position occupied after implantation. The formation of this system is connected with the redistribution of oxygen in a thin layer under the surface. This effect does not take place precisely at the same temperature in foils and in single crystals.


1994 ◽  
Vol 66 (1-3) ◽  
pp. 398-402 ◽  
Author(s):  
Lynann Clapham ◽  
J.L. Whitton ◽  
J.A. Jackman ◽  
M.C. Ridgway

2000 ◽  
Vol 128-129 ◽  
pp. 43-50 ◽  
Author(s):  
T Cabioc’h ◽  
M Jaouen ◽  
E Thune ◽  
P Guérin ◽  
C Fayoux ◽  
...  

1994 ◽  
Vol 9 (11) ◽  
pp. 2823-2838 ◽  
Author(s):  
B.K. Gupta ◽  
Bharat Bhushan ◽  
C. Capp ◽  
J.V. Coe

In previous studies, sublimed C60-rich fullerene films on silicon, when slid against a 52100 steel ball under dry conditions, have exhibited low coefficient of friction (∼0.12). Films with different purities can be produced by sublimation at different substrate temperatures. In this paper, effects of purity of fullerene films and ion implantation of the films with Ar ions on the friction and wear properties of sublimed fullerene films are reported. C60-rich films (called here films with high purity) exhibit low macroscale friction. An increased amount of C70 and impurities in the fullerene film determined using Raman and Fourier transform infrared (FTIR), increases its coefficient of friction. Microscale friction measurements using friction force microscopy also exhibited similar trends. Low coefficient of friction of sublimed C60-rich films on silicon is probably due to the formation of a tenacious transfer film of C60 molecules on the mating 52100 steel ball surface. Based on scanning tunneling microscopy (STM), transmission electron microscopy (TEM), and high resolution TEM (HRTEM), we found that fullerene films primarily consisted of C60 molecules in a fcc lattice structure. Nanoindenter was used to measure hardness and elastic modulus of the as-deposited films. Ion-implantation with 1 × 1016 Ar+ cm−2 reduced macroscale friction down to about 0.10 from 0.12 with an increase in wear life by a factor of 4; however, doses of 5 × 1016 ions cm−2 gave three times higher friction and poorer wear life; higher doses disintegrated the C60 molecules. Based on STM, TEM, Raman, FTIR, and laser desorption Fourier-transform ion cyclotron resonance mass spectrometer (LD/FT/ICR) studies, we found that the ion implantation with a dose of 1 × 1016 Ar+ cm−2 resulted in smoothening of the fullerene film surface probably by compacting clusters, but without disintegrating the C60 molecules. However, a high dose of 5 × 1016 Ar+ cm−2 damaged the C60 molecules, converting it to an amorphous carbon. Nanoindentation studies show that ion implantation with a dose of 1 × 1016 Ar+ cm−2 resulted in an increase in the hardness from about 1.2 to 4.0 GPa and in elastic modulus from about 70 to 75 GPa and modified the elastic-plastic deformation behavior.


1980 ◽  
Vol 1 ◽  
Author(s):  
S.W. Chiang ◽  
Y.S. Liu ◽  
R.F. Reihl

ABSTRACTHigh-dose ion implantation (1017 ions-cm−2) of C+, N+, and O+ at 50 KeV into silicon followed by pulsed laser annealing at 1.06 μm was studied. Formation of SiC, Si3N4, and SiO2 has been observed and investigated using Transmission Electron Microscopy (TEM) and Differential Fourier-Transform Infrared (FT-IR) Spectroscopy. Furthermore, in N+-implanted and laser-annealed silicon samples, we have observed a cell-like structure which has been identified to be spheroidal polycrystalline silicon formed by the rapid laser irradiation.


1986 ◽  
Vol 97 (3-4) ◽  
pp. 191-197 ◽  
Author(s):  
D. Scholten ◽  
A. J. Burggraaf

2002 ◽  
Vol 716 ◽  
Author(s):  
Takaaki Amada ◽  
Nobuhide Maeda ◽  
Kentaro Shibahara

AbstractAn Mo gate work function control technique which uses annealing or N+ ion implantation has been reported by Ranade et al. We have fabricated Mo-gate MOS diodes, based on their report, with 5-20 nm SiO2 and found that the gate leakage current was increased as the N+ implantation dose and implantation energy were increased. Although a work function shift was observed in the C-V characteristics, a hump caused by high-density interface states was found for high-dose specimens. Nevertheless, a work function shift larger than -1V was achieved. However, nitrogen concentration at the Si surface was about 1x1020 cm-3 for the specimen with a large work function shift.


Sign in / Sign up

Export Citation Format

Share Document