Daily writing carbon ink: Novel application on humidity sensor with wide detection range, low detection limit and high detection resolution

2021 ◽  
Vol 339 ◽  
pp. 129884
Author(s):  
Zaihua Duan ◽  
Yadong Jiang ◽  
Qiuni Zhao ◽  
Qi Huang ◽  
Si Wang ◽  
...  
2021 ◽  
Author(s):  
Siddesh Umapathi ◽  
Harish Singh ◽  
Jahangir Masud ◽  
Manashi Nath

CuSe nanostructures exhibit high-efficiency for glucose detection with high sensitivity (19.419 mA mM−1 cm−2) and selectivity at low applied potential (0.15 V vs. Ag|AgCl), low detection limit (0.196 μM) and linear detection range (100 nM to 40 μM).


2021 ◽  
Vol 13 (15) ◽  
pp. 1832-1838
Author(s):  
Jiaxi Cheng ◽  
Fenghua Jiang ◽  
Siqi Zhang

We develop a label-free, sensitive and selective nanochannel sensing platform for detection of TC. The nanosensor provided a low detection limit, a wide detection range and excellent recovery rate in different water samples.


2020 ◽  
Vol 13 (1) ◽  
Author(s):  
Fang Xin Hu ◽  
Tao Hu ◽  
Shihong Chen ◽  
Dongping Wang ◽  
Qianghai Rao ◽  
...  

Abstract Uric acid (UA) detection is essential in diagnosis of arthritis, preeclampsia, renal disorder, and cardiovascular diseases, but it is very challenging to realize the required wide detection range and low detection limit. We present here a single-atom catalyst consisting of Co(II) atoms coordinated by an average of 3.4 N atoms on an N-doped graphene matrix (A–Co–NG) to build an electrochemical biomimetic sensor for UA detection. The A–Co–NG sensor achieves a wide detection range over 0.4–41,950 μM and an extremely low detection limit of 33.3 ± 0.024 nM, which are much better than previously reported sensors based on various nanostructured materials. Besides, the A–Co–NG sensor also demonstrates its accurate serum diagnosis for UA for its practical application. Combination of experimental and theoretical calculation discovers that the catalytic process of the A–Co–NG toward UA starts from the oxidation of Co species to form a Co3+–OH–UA*, followed by the generation of Co3+–OH + *UA_H, eventually leading to N–H bond dissociation for the formation of oxidized UA molecule and reduction of oxidized Co3+ to Co2+ for the regenerated A–Co–NG. This work provides a promising material to realize UA detection with wide detection range and low detection limit to meet the practical diagnosis requirements, and the proposed sensing mechanism sheds light on fundamental insights for guiding exploration of other biosensing processes.


Author(s):  
Chin-Yih Hong ◽  
Shieh-Yueh Yang ◽  
K. W. Huang ◽  
Herng-Er Horng ◽  
Hong-Chang Yang

The popular bio-marker for colon cancer is carcinoembryonic antigen (CEA). By conjugating anti-CEA onto magnetic nanoparticles, CEA can be specially labeled and detected by measuring magnetic signals via immunomagnetic reduction (IMR). The low detection limit and detection range of IMR on CEA are investigated. The results are compared with those by using the existing assay, such as enzyme-linked immunosorbent assay (ELISA). It is evidenced that IMR has sensitivity much higher than that of ELISA. The low detection limit is below the normal level of CEA concentration of clinic practice and is suitable for early-stage in-vitro diagnosis for colon cancer. Furthermore, the dynamic range of detection for the CEA concentration using IMR extends well above the threshold of high risk level of colorectal carcinoma in current diagnosing practice. Therefore, IMR is also suitable in other stages diagnosis for colon cancer development.


2016 ◽  
Vol 45 (13) ◽  
pp. 5833-5840 ◽  
Author(s):  
Mohit Saraf ◽  
Kaushik Natarajan ◽  
Shaikh M. Mobin

An enzymeless glucose sensor (MCSPE) based on copper oxide microspheres (CMS) prepared by hydrothermal reaction of copper nitrate and sucrose, can sense glucose in a wide linear detection range with good sensitivity and low detection limit.


RSC Advances ◽  
2019 ◽  
Vol 9 (15) ◽  
pp. 8628-8637 ◽  
Author(s):  
Maisyn Picard ◽  
Suman Thakur ◽  
Manjusri Misra ◽  
Amar K. Mohanty

Fluorescent carbon dots for the selective and sensitive detection of Fe3+ ions with a wide detection range and very low detection limit.


Author(s):  
J. J. Domanski ◽  
P. L. Haire ◽  
T.J. Sheets

AbstractAverage residue Ievels of DDT + TDE in flue-cured tobacco decreased from 6.1 ppm in 1970 to 0.85 ppm in 1972. DDT + TDE residues in Burley also dropped sharply from previous levels. In 1972 one sample from Kentucky contained 8.17 ppm; all other Burley samples were less than 0.25 ppm. DDT + TDE residues also declined in fire-cured and air-cured types; of these samples Tennessee dark air-cured tobacco contained the highest average residue (3.5 ppm of DDT + TDE). In 1972 over 90 % of the flue-cured samples were positive for toxaphene. Since each of our samples was a composite of tobacco from 10 farmers, we cannot conclude from this result that 90 % of the individual piles contained toxaphene. Significant amounts of toxaphene were found in other types also; for example, 50 % of the 1972 Burley samples had toxaphene concentrations greater than 0.5 ppm. Average endosulfan levels decreased between 1970 and 1972 in flue-cured and Burley tobaccos. However, in all of the dark air and dark fire-cured samples from Tennessee endosulfan residues exceeded 5 ppm. Average endrin residues were at or near the low detection limit in alI samples except fire-cured and dark air-cured tobacco from Tennessee; these averaged 0.26 and 0.17 ppm, respectively.


2021 ◽  
Author(s):  
Bo Liu ◽  
Luanying Yang ◽  
Gang Wang ◽  
Sha He ◽  
Xiaobo Wang ◽  
...  

A simple and low-cost electrochemical CEA immunosensor was investigated via the self-polymerization of dopamine and a dithiol compound spacer for the covalent immobilization of antibodies. The designed CEA immunosensor exhibited a linear response and a low detection limit.


Author(s):  
Ziyu Wang ◽  
Meiyun Xu ◽  
Nan Zhang ◽  
Jian-Bin Pan ◽  
Xinqi Wu ◽  
...  

A mechanism of co-reactive group poisoning (CGP) was discovered for designing efficient I2 vapor sensors for early warning of a nuclear emergency, which give an ultra-low detection limit of 0.13 ppt as well as high selectivity.


2016 ◽  
Vol 18 (34) ◽  
pp. 23795-23802 ◽  
Author(s):  
Xiaolong Wang ◽  
Lu Zhou ◽  
Wei Lai ◽  
Tao Jiang ◽  
Jun Zhou

We present a recyclable SERS-based immunoassay for CA19-9 with a low detection limit of 5 U mL−1. The linking between TiO2-NTs and 4MBA was destroyed by catalyzing 4MBA into 4-sulfobenzoate upon UV irradiation, which was clarified by UPLC/ESI-tqMS and density functional theory.