scholarly journals Graduation technique for vibration flow device for grain mass moisture control

2021 ◽  
Vol 37 ◽  
pp. 00099
Author(s):  
Alexander Ivashina ◽  
Andrey Adoshev ◽  
Sergey Antonov ◽  
Valery Zhdanov

The article shows that sampling of grain while controlling the moisture content is carried out in accordance with the current recommendations and standards. The mass of a sample should be sufficient to form 10-15 samples with uniformly distributed moisture values with an interval of no more than 3-4% in the measurement range of a vibration-flow moisture meter. Determination of grain moisture is carried out by the thermogravimetric method using a drying oven as a standard in the following sequence. Measurements with a moisture meter are taken at least three times. For the final measurement result, the average value α of the moisture meter readings from a series of successive measurements is taken. The range in a series of measurements should not exceed 0.05α; otherwise the measurements are repeated. The moisture measurement results and the corresponding readings of the device are entered in the appropriate table. When constructing graduation curves, a correlation-regression analysis of the measurement results is carried out, which is as follows. A correlation field is constructed - a graphical representation of the relationship between the moisture values of the material Wi and the readings of the moisture meter αi. If the analysis is performed correctly, the theoretical regression line plotted on the correlation field should be located as close as possible to the experimental measurement points. The basic error of the vibration-flow moisture meter, obtained as a result of the calculation, should not exceed the permissible value. Otherwise, the graduation of the moisture meter is repeated.

Nukleonika ◽  
2019 ◽  
Vol 64 (3) ◽  
pp. 103-109
Author(s):  
Zeki U. Yumun ◽  
Erol Kam

Abstract In this study, the heavy metal and radioactive properties of Iznik Lake were investigated. Concentration values of the first (Ag, Bi, Mo, Sn, Se, Zn, As, B, Cd, Co, Cr, Cu, Ni, Pb, Pt and Sb) and second (Na, Mg, K, Ca, P, S, Fe, Al and Mn) group of elements in borehole 1 (BH-1) drilling did not show much variation from the top to the bottom of the drilling. Concentration values of the first group of elements in borehole 2 (BH-2) drill samples decreased at higher levels of drilling. In addition, natural and anthropogenic radionuclides were measured by gamma spectrometry, and the results of environmental natural radioactivity of Iznik Lake and its surroundings were determined. In the measurement results, Ra-226 was found to be below the world average value at all locations. It is assumed that the determination of K-40 values above the average values was due to agricultural activities carried out intensively in the study area. Th-232 values were found to be below the world average value in drilling samples; Cs-137 values were below the background level in all samples. According to these results, the study area does not contain any unnatural radioactivity.


2020 ◽  
pp. 3-8
Author(s):  
L.F. Vitushkin ◽  
F.F. Karpeshin ◽  
E.P. Krivtsov ◽  
P.P. Krolitsky ◽  
V.V. Nalivaev ◽  
...  

The State special primary acceleration measurement standard for gravimetry (GET 190-2019), its composition, principle of operation and basic metrological characteristics are presented. This standard is on the upper level of reference for free-fall acceleration measurements. Its accuracy and reliability were improved as a result of optimisation of the adjustment procedures for measurement systems and its integration within the upgraded systems, units and modern hardware components. A special attention was given to adjusting the corrections applied to measurement results with respect to procedural, physical and technical limitations. The used investigation methods made it possibled to confirm the measurement range of GET 190-2019 and to determine the contributions of main sources of errors and the total value of these errors. The measurement characteristics and GET 90-2019 were confirmed by the results obtained from measurements of the absolute value of the free fall acceleration at the gravimetrical site “Lomonosov-1” and by their collation with the data of different dates obtained from measurements by high-precision foreign and domestic gravimeters. Topicality of such measurements ensues from the requirements to handle the applied problems that need data on parameters of the Earth gravitational field, to be adequately faced. Geophysics and navigation are the main fields of application for high-precision measurements in this field.


2005 ◽  
Vol 1 (1) ◽  
pp. 77-93
Author(s):  
Bíborka Gillay ◽  
David B. Funk

The price paid for corn is usually based on 15.0 or 15.5 percent moisture content. However, corn must be dried below 13 percent moisture to ensure safe storage for a year or more. In the U.S., such stored corn cannot be directly remoistened before selling it, but it can be mixed with moist new-crop corn. Accurate moisture measurement of mixtures of dry and moist corn is important to permit adjustment of blending ratios to maximize profitability, but grain moisture meters are less accurate for mixtures of wet and dry grain. This research evaluated the differences between dielectric-type moisture meter results for mixed and equilibrated corn samples at different moisture levels and different measurement frequencies. Equilibrated grain samples tended to give lower moisture results than recently mixed grain samples - especially in the 1 to 10 MHz region. These differences permitted detection of mixtures by using moisture measurements at two frequencies.


1968 ◽  
Vol 51 (4) ◽  
pp. 752-755
Author(s):  
Edward L Pratt ◽  
Morris E Auerbach

Abstract Raceophenidol in feed at concentration levels intended for growth promotion of poultry can be estimated by a curvature inversion measurement related to the ultraviolet spectrum of derived p-methylsulfonylbenzaldehyde. The drug can be accurately measured at the 0.0005% level. Collaborative studies on the method showed an average value of 94 ± 10% of claim. The method is recommended for adoption as official, first action.


2015 ◽  
Vol 72 (2) ◽  
pp. 123-131 ◽  
Author(s):  
Marko Igic ◽  
Nebojsa Krunic ◽  
Ljiljana Aleksov ◽  
Milena Kostic ◽  
Aleksandra Igic ◽  
...  

Background/Aim. The vertical dimension of occlusion is a very important parameter for proper reconstruction of the relationship between the jaws. The literature describes many methods for its finding, from the simple, easily applicable clinically, to quite complicated, with the use of one or more devices for determination. The aim of this study was to examine the possibility of determining the vertical dimension of occlusion using the vocals ?O? and ?E? with the control of values o btained by applying cognitive functions. Methods. This investigation was performed with the two groups of patients. The first group consisted of 50 females and 50 males, aged 18 to 30 years. In this group the distance between the reference points (on top of the nose and chin) was measured in the position of the mandible in the vertical dimension of occlusion, the vertical dimension at rest and the pronunciation of the words ?OLO? and ?ELE?. Checking the correctness of the particular value for the word ?OLO? was also performed by the phonetic method with the application of cognitive exercises when the patients counted from 89 to 80. The obtained difference in the average values i n determining the vertical dimension of occlusion and the ?OLO? and ?ELE? in the first group was used as the reference for determining the vertical dimension of occlusion in the second group of patients. The second group comprised of 31 edentulous persons (14 females and 17 males), aged from 54 to 85 years who had been made a complete denture. Results. The average value obtained for the vertical dimension of rest for the entire sample was 2.16 mm, for the word ?OLO? for the entire sample was 5.51 mm and for the word ?ELE? for the entire sample was 7.47 mm. There was no statistically significant difference between the genders for the value of the vertical dimension at rest, ?ELE? and ?OLO?. There was a statistically significant difference between the values f or the vertical dimension at rest, ?OLO? and ?ELE? for both genders. There was a statistically significant correlation between the value for the vertical dimension at rest, ?OLO? and ?ELE?, for both groups of subjects. Conclusion. Determining the vertical dimension of occlusion requires 5.5 mm subtraction from the position of the mandible in pronunciation of the word ?OLO? or 7.5 mm in pronunciation of the word ?ELE?.


2015 ◽  
Vol 8 (2) ◽  
Author(s):  
Andrew Johnson ◽  
Xianwen Kong ◽  
James Ritchie

The determination of workspace is an essential step in the development of parallel manipulators. By extending the virtual-chain (VC) approach to the type synthesis of parallel manipulators, this technical brief proposes a VC approach to the workspace analysis of parallel manipulators. This method is first outlined before being illustrated by the production of a three-dimensional (3D) computer-aided-design (CAD) model of a 3-RPS parallel manipulator and evaluating it for the workspace of the manipulator. Here, R, P and S denote revolute, prismatic and spherical joints respectively. The VC represents the motion capability of moving platform of a manipulator and is shown to be very useful in the production of a graphical representation of the workspace. Using this approach, the link interferences and certain transmission indices can be easily taken into consideration in determining the workspace of a parallel manipulator.


2011 ◽  
Vol 291-294 ◽  
pp. 1039-1042
Author(s):  
Wei Xie ◽  
Shao Wei Tu ◽  
Qi Qing Huang ◽  
Ya Zhi Li

In the present work, the resistance to crack extension of 2524-T3 aluminum alloy under Mode I loading was studied by using the middle-cracked tension M (T) specimens. The curve, plane-stress fracture toughness and apparent plane-stress fracture toughness were calculated by test data. The average value of measured fracture toughness at room temperature was 161 MPam1/2. The results and conclusions can be referred in airplane skin design.


Author(s):  
A. Ya. Krasil’nikov ◽  
A. A. Krasil’nikov

The article considers the possibility of applying a standard method for calculating the repulsive force for a thick high-coercive permanent magnets from samarium-cobalt alloy in a magnetic system. The results of the research allowed us to introduce correction coefficients in the method of calculating the repulsive force in a magnetic system with such magnets, depending on the air gap between of them. It is shown that the repulsive forces of the North poles of permanent magnets differ from the repulsive forces of the South poles. The research was carried out with magnets manufactured by different enterprises. When calculating the repulsive force, the average value of the repulsive force between the North and South poles of magnets is found.


2011 ◽  
Vol 4 (1) ◽  
pp. 29-35 ◽  
Author(s):  
A. Desmarchelier ◽  
W. Seefelder

It is well known that cereal crops exposed to deoxynivalenol (DON) infection are capable of detoxifying this mycotoxin through the plant metabolism. In this context, one major pathway is the conjugation of DON to a glucose moiety giving rise to 3-β-D-glucopyranosyl-4-deoxynivalenol (D3G). Though no longer toxic for plants, this metabolite may potentially be hydrolysed in the digestive tract of humans and animals, releasing thus the toxic precursor (DON). The co-occurrence of DON and D3G in cereal-based products has already been reported but data about their absolute and relative concentrations are still insufficient. In order to contribute to a better understanding of the significance of D3G, the quantitative determination of DON and D3G has been carried out in 22 cereal samples and 4 malt-based products collected from 9 countries by liquid chromatography-tandem mass spectrometry (LCMS/ MS). DON was detected in all cereal samples (min: 3 µg/kg; max: 2,864 µg/kg; median: 176 µg/kg) but only in 1 malt-based product (16 µg/kg) whereas D3G was detected in 21 cereal samples (min: <1 µg/kg; max: 367 µg/kg; median: 19 µg/kg) and only in 1 malt-based product (6 µg/kg). The proportion of D3G in relation to DON concentration was within a 6-29% range with an average value at 12±7% in the tested samples.


1987 ◽  
Vol 30 (3) ◽  
pp. 0853-0857 ◽  
Author(s):  
Spires Mexas ◽  
G. H. Brusewitz

Sign in / Sign up

Export Citation Format

Share Document