scholarly journals Theoretical and experimental analysis on environmental pollution with exhaust gases at the mechanical dislocation of rocks, located in a protected nature environment

2022 ◽  
Vol 354 ◽  
pp. 00067
Author(s):  
Marin Silviu Nan ◽  
Daniel Cosmin Vitan ◽  
Sorina Daniela Anotoiu ◽  
Cristian Aron

The paper approaches the theoretical and experimental analysis of the level of exhaust gas pollution in a protected nature environmental, located in the mountain area, for excavation a trench. Due to the legislative provisions prohibiting the use of explosives in the nature reservation or other protected nature environmental areas, the mechanized excavation solution remains the only viable option. Excavation the trench through the mechanized solution must be carried out, taking into account the maximum level of pollution with exhaust gases provided in the legislative norms. According to the geotechnical data, the rock composition to be excavated on the route will be of different hardness, which involves impactors of various powers to displace the rock, on the one hand, and on the other, different excavators and bulldozers for the handling the material resulted from excavation. The theoretical research required to solve the problem has several stages, of which we mention: choosing the correct mechanization solution for displacing the hard and very hard rock; determination of fuel consumption, and energy consumption, respectively, transformation of the energy consumed in the liquid fuel necessary for the tool driving engines, and which generate exhaust gases.

2013 ◽  
Vol 2013 ◽  
pp. 1-10 ◽  
Author(s):  
Małgorzata Szewczyńska ◽  
Małgorzata Pośniak ◽  
Elżbieta Dobrzyńska

In order to characterize PAHs emissions of diesel engine fuelled with diesel and its blend (B20, B40). In the particle phase, PAHs in engine exhausts were collected by fiberglass filters using Electrical Low Pressure Impactor (ELPI) and then determined by a high performance liquid chromatography with a fluorimetric detector (HPLC-FL). The main content in exhaust gases from diesel engine, regardless the type of applied fuel, is constituted by the particles fraction of diameter <0.25 μm. Particles sized <0.25 μm constituted on average approximately 68% of particles in diesel exhaust gases and approx. 50% of particles emitted by biodiesel B20 and B40. When the B100 bioester additive was applied, the total emission of particles was reduced thus the volume of toxic substances adsorbed on them was lower. The analysis of chemical composition of <0.25 μm exhaust gas fraction showed that there were mainly 3- and 4-ring aromatic hydrocarbons in the exhaust gas of diesel fuel while in B40 single PAHs with the number of rings of 4 and 5 were detected. An application of ELPI permitted a further separation of <0.25 μm particle’s fraction and a real-time determination of interalia number, mass, and surface concentrations.


1967 ◽  
Vol 18 (01/02) ◽  
pp. 198-210 ◽  
Author(s):  
Ronald S Reno ◽  
Walter H Seegers

SummaryA two-stage assay procedure was developed for the determination of the autoprothrombin C titre which can be developed from prothrombin or autoprothrombin III containing solutions. The proenzyme is activated by Russell’s viper venom and the autoprothrombin C activity that appears is measured by its ability to shorten the partial thromboplastin time of bovine plasma.Using the assay, the autoprothrombin C titre was determined in the plasma of several species, as well as the percentage of it remaining in the serum from blood clotted in glass test tubes. Much autoprothrombin III remains in human serum. With sufficient thromboplastin it was completely utilized. Plasma from selected patients with coagulation disorders was assayed and only Stuart plasma was abnormal. In so-called factor VII, IX, and P.T.A. deficiency the autoprothrombin C titre and thrombin titre that could be developed was normal. In one case (prethrombin irregularity) practically no thrombin titre developed but the amount of autoprothrombin C which generated was in the normal range.Dogs were treated with Dicumarol and the autoprothrombin C titre that could be developed from their plasmas decreased until only traces could be detected. This coincided with a lowering of the thrombin titre that could be developed and a prolongation of the one-stage prothrombin time. While the Dicumarol was acting, the dogs were given an infusion of purified bovine prothrombin and the levels of autoprothrombin C, thrombin and one-stage prothrombin time were followed for several hours. The tests became normal immediately after the infusion and then went back to preinfusion levels over a period of 24 hrs.In other dogs the effect of Dicumarol was reversed by giving vitamin K1 intravenously. The effect of the vitamin was noticed as early as 20 min after administration.In response to vitamin K the most pronounced increase was with that portion of the prothrombin molecule which yields thrombin. The proportion of that protein with respect to the precursor of autoprothrombin C increased during the first hour and then started to go down and after 3 hrs was equal to the proportion normally found in plasma.


1969 ◽  
Vol 61 (2) ◽  
pp. 219-231 ◽  
Author(s):  
V. H. Asfeldt

ABSTRACT This is an investigation of the practical clinical value of the one mg dexamethasone suppression test of Nugent et al. (1963). The results, evaluated from the decrease in fluorimetrically determined plasma corticosteroids in normal subjects, as well as in cases of exogenous obesity, hirsutism and in Cushing's syndrome, confirm the findings reported in previous studies. Plasma corticosteroid reduction after one mg of dexamethasone in cases of stable diabetes was not significantly different from that observed in control subjects, but in one third of the insulin-treated diabetics only a partial response was observed, indicating a slight hypercorticism in these patients. An insufficient decrease in plasma corticosteroids was observed in certain other conditions (anorexia nervosa, pituitary adenoma, patients receiving contraceptive or anticonvulsive treatment) with no hypercorticism. The physiological significance of these findings is discussed. It is concluded that the test, together with a determination of the basal urinary 17-ketogenic steroid excretion, is suitable as the first diagnostic test in patients in whom Cushing's syndrome is suspected. In cases of insufficient suppression of plasma corticosteroids, further studies, including the suppression test of Liddle (1960), must be carried out.


2013 ◽  
Vol 12 (7) ◽  
pp. 451-459
Author(s):  
Ashraf Yehia El-Naggar ◽  
Mohamed A. Ebiad

Gasoline come primarily from petroleum cuts, it is the preferred liquid fuel in our lives. Two gasoline samples of octane numbers 91 and 95 from Saudi Arabia petrol stations were studied. This study was achieved at three different temperatures 20oC, 30oC and 50oC representing the change in temperatures of the different seasons of the year. Both the evaporated gases of light aromatic hydrocarbons (BTEX) of gasoline samples inside the tank were subjected to analyze qualitatively and quantitatively via capillary gas chromatography. The detailed hydrocarbon composition and the octane number of the studied gasoline samples were determined using detailed hydrocarbon analyzer. The idea of research is indicating the impact of light aromatic compounds in gasoline on the toxic effect of human and environment on the one hand, and on octane number of gasoline on the other hand. Although the value of octane number will be reduced but this will have a positive impact on the environment as a way to produce clean fuel.


2020 ◽  
Vol 17 ◽  
Author(s):  
Houli Li ◽  
Di Zhang ◽  
Xiaoliang Cheng ◽  
Qiaowei Zheng ◽  
Kai Cheng ◽  
...  

Background: The trough concentration (Cmin) of Imatinib (IM) is closely related to the treatment outcomes and adverse reactions of patients with gastrointestinal stromal tumors (GIST). However, the drug plasma level has great interand intra-individual variability, and therapeutic drug monitoring (TDM) is highly recommended. Objective: To develop a novel, simple, and economical two-dimensional liquid chromatography method with ultraviolet detector (2D-LC-UV) for simultaneous determination of IM and its major active metabolite, N-demethyl imatinib (NDIM) in human plasma, and then apply the method for TDM of the drug. Method: Sample was processed by simple protein precipitation. Two target analytes were separated on the one-dimension column, captured on the middle column, and then transferred to the two-dimension column for further analysis. The detection was performed at 264 nm. The column temperature was maintained at 40˚C and the injection volume was 500 μL. Totally 32 plasma samples were obtained from patients with GIST who were receiving IM. Method: Sample was processed by simple protein precipitation. Two target analytes were separated on the one-dimension column, captured on the middle column, and then transferred to the two-dimension column for further analysis. The detection was performed at 264 nm. The column temperature was maintained at 40˚C and the injection volume was 500 μL. Totally 32 plasma samples were obtained from patients with GIST who were receiving IM. Conclusion: The novel 2D-LC-UV method is simple, stable, highly automated and independent of specialized technicians, which greatly increases the real-time capability of routine TDM for IM in hospital.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4842
Author(s):  
Waldemar Kamiński

Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the controlled points (CPs). The reference sensor is the one that is placed at the point that (in theoretical assumptions) is not a subject to vertical displacements and the displacements of controlled points are determined according to its height. The hydrostatic levelling rule comes from the Bernoulli’s law. While using the Bernoulli’s principle in hydrostatic levelling, the following components have to be taken into account: atmospheric pressure, force of gravity, density of liquid used in sensors places at CPs. The parameters mentioned above are determined with some mean errors that influence on the accuracy assessment of vertical displacements. In the subject’s literature, there are some works describing the individual accuracy analyses of the components mentioned above. In this paper, the author proposes the concept of comprehensive determination of mean error of vertical displacement (of each CPs), calculated from the mean errors’ values of components dedicated for specific HLS. The formulas of covariances’ matrix were derived and they enable to make the accuracy assessment of the calculations’ results. The author also presented the subject of modelling of vertical displacements’ gained values. The dependences, enabling to conduct the statistic tests of received model’s parameters, were implemented. The conducted tests make it possible to verify the correctness of used theoretical models of the examined object treated as the rigid body. The practical analyses were conducted for two simulated variants of sensors’ connections in HLS. Variant no. I is the sensors’ serial connection. Variant no. II relies on the connection of each CPs with the reference sensor. The calculations’ results show that more detailed value estimations of the vertical displacements can be obtained using variant no. II.


1975 ◽  
Vol 68 ◽  
pp. 239-241
Author(s):  
John C. Brown ◽  
H. F. Van Beek

SummaryThe importance and difficulties of determining the height of hard X-ray sources in the solar atmosphere, in order to distinguish source models, have been discussed by Brown and McClymont (1974) and also in this Symposium (Brown, 1975; Datlowe, 1975). Theoretical predictions of this height, h, range between and 105 km above the photosphere for different models (Brown and McClymont, 1974; McClymont and Brown, 1974). Equally diverse values have been inferred from observations of synchronous chromospheric EUV bursts (Kane and Donnelly, 1971) on the one hand and from apparently behind-the-limb events (e.g. Datlowe, 1975) on the other.


2009 ◽  
Vol 39 (1) ◽  
pp. 339-370 ◽  
Author(s):  
Robert J. Thomson ◽  
Dmitri V. Gott

AbstractIn this paper, a long-term equilibrium model of a local market is developed. Subject to minor qualifications, the model is arbitrage-free. The variables modelled are the prices of risk-free zero-coupon bonds – both index-linked and conventional – and of equities, as well as the inflation rate. The model is developed in discrete (nominally annual) time, but allowance is made for processes in continuous time subject to continuous rebalancing. It is based on a model of the market portfolio comprising all the above-mentioned asset categories. The risk-free asset is taken to be the one-year index-linked bond. It is assumed that, conditionally upon information at the beginning of a year, market participants have homogeneous expectations with regard to the forthcoming year and make their decisions in mean-variance space. For the purposes of illustration, a descriptive version of the model is developed with reference to UK data. The parameters produced by that process may be used to inform the determination of those required for the use of the model as a predictive model. Illustrative results of simulations of the model are given.