A Biomechanical Comparison of Composite Fixation and Veterinary Acetabular Plates for Stabilization of Acetabular Osteotomies in Dogs Loaded in Three-Point-Bending Fashion

1998 ◽  
Vol 11 (03) ◽  
pp. 152-157 ◽  
Author(s):  
D. D. Lewis ◽  
J. B. Madison ◽  
L. L. Blaeser ◽  
O. I. Ianz

SummaryAn in vitro study comparing the biomechanical performance and accuracy of reduction for two methods of acetabular osteotomy repair in the dog is presented. Pelves were harvested from five adult mixed breed dogs weighing 25-30 kg. On e hemipelvis from each dog was repaired with the composite fixation and the contralateral hemipelvis was repaired with a 2.0 mm six hole veterinary acetabular plate. Eac h hemipelvis was loaded in a threepoint- bending fashion at a rate of 5 mm/min. An extensometer was placed over the dorso-medial surface of the acetabular osteotomy during loading. Reduction was significantly better for hemipelves stabilized with the composite fixation when compared to hemipelves stabilized with the 2.0 mm six hole veterinary acetabular plate. There was not a significant difference in bending stiffness, distractional stiffness, yield point and maximum load between repair groups.An in vitro comparison was made between a composite fixation method and acetabular plates for the stabilisation of acetabular osteotomies.

2016 ◽  
Vol 7 (3) ◽  
pp. 119-122
Author(s):  
K Pradeep ◽  
MA Kuttappa ◽  
Adarsh Kudva ◽  
Roshni Butula

ABSTRACT Objectives The objective of this study is to measure and compare the compressive strength of two bulk-fill posterior composites (Smart dentin replacement or SDR and Filtek bulk fill) with universal nanohybrid composite (Filtek Z 250XT). Materials and methods In this in vitro study, three different types of posterior composites are used as follows: Group 1 – SDR (Dentsply, Konstanz, Germany); group 2 – Filtek bulk-fill (3M ESPE, St. Paul, MN, USA); group 3 – Filtek Z-250XT (3M ESPE, St. Paul, MN, USA). Ten cylindrical samples of 6 mm height and 4 mm diameter in each group were made using a split brass mold. The composites filled in the brass mold were photopolymerized using light-emitting diode (LED) light-curing unit and the cured samples were stored in water at 37°C for 48 hours before testing. The compressive strength of the stored samples was tested using universal testing machine (Instron 3366, UK) at a cross-head speed of 0.5 mm/minute. The compressive strength was calculated by dividing the maximum load with area of the samples. Results Results are statistically analyzed using one-way analysis of variance (ANOVA) with Tukey's post hoc test. Analysis showed that SDR and Filtek bulk-fill have greater compressive strength than Filtek Z-250 (p < 0.05). However, there is no statistical difference between compressive strength of SDR and Filtek bulk-fill composites (p > 0.05). How to cite this article Pradeep K, Ginjupalli K, Kuttappa MA, Kudva A, Butula R. In vitro Comparison of Compressive Strength of Bulk-fill Composites and Nanohybrid Composite. World J Dent 2016;7(3):119-122.


Author(s):  
Rathika Rai ◽  
M. A. Easwaran ◽  
K. T. Dhivya

Aim: To evaluate the surface detail reproduction of dental stone this is immersed in different disinfectant solution and studied under stereomicroscope. Methodology: Total number of 30 specimens of dental stone (Type III) were made with measurements of 1.5cm diameter and 1cm height .This samples are divided in to 3 groups group A,B,C. were A is immersed in Distilled water which was taken as control group ;B is immersed in 2% Glutaraldehyde and C is immersed in 5%sodium hypochlorite. Each specimen were immersed in the disinfectant solution for 15 minutes and dried under room temperature for 24 hrs. After 24 hrs each specimens are studied under stereomicroscope for surface details. Result: The results showed no significant difference in the surface irregularities and porosities for a group 1 and group 2 except group 3 which showed significant increase in the porosities, surface irregularities and erosions after disinfection with 5% NaHOCl by immersion method. Conclusion: The surface detail reproduction capacity of die stone was adversely affected when 5% Sodium hypochlorite was used as disinfectant solution when compare d to control group and 2% Glutaraldehyde


2021 ◽  
Vol 6 ◽  
pp. 247275122110192
Author(s):  
Karel Kuik ◽  
Jean Pierre T. F. Ho ◽  
Cornelis Klop ◽  
Maurits H. T. de Ruiter ◽  
Cornelis J. Kleverlaan ◽  
...  

Study Design: Biomechanical in vitro study. Mandibular advancement after sagittal split ramus osteotomy (SSRO) is a common procedure in orthognathic surgery. Several fixation methods are used for stabilization of SSRO. Objective: The aim of this study was to compare a new fixation method (gridplate) with more contemporary applied methods of fixation. Material and Methods: In this study, 50 polyurethane hemimandibles with a prefabricated SSRO were used as specimens. All hemimandibles were advanced by 8 mm and divided into 5 groups with different fixation methods: (A) one 4-hole miniplate with 4 monocortical screws; (B) two 4-hole miniplates with 8 monocortical screws; (C) one 4-hole miniplate with 4 monocortical screws and 1 bicortical screw in the retromolar area (hybrid method); (D) 3 bicortical screws in an inverted-L pattern; and (E) one 8-hole gridplate with 8 monocortical screws. Loads in newtons were recorded at displacements of the mandibular incisive edge at 1 mm, 3 mm and 5 mm. Results: Fixation with 3 bicortical screws and the gridplate presented the most stability, followed by two 4-hole miniplates. Fixation with the hybrid method or the single miniplate showed the least stability. Conclusion: According to the results of this study, the 8-hole gridplate design appears a sufficient fixation method regarding stabilization of SSRO with larger mandibular advancement.


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2009 ◽  
Vol 38 (1) ◽  
pp. 40-48 ◽  
Author(s):  
PAUL A. KLOC ◽  
MICHAEL P. KOWALESKI ◽  
ALAN S. LITSKY ◽  
NANCY O. BROWN ◽  
KENNETH A. JOHNSON

2015 ◽  
Vol 85 (6) ◽  
pp. 920-926 ◽  
Author(s):  
Ricardo Carvalho Bueno ◽  
Roberta Tarkany Basting

ABSTRACT Objective:  To evaluate the proliferation and morphology of human osteoblasts cultured on two brands of mini-implants after 24, 48, and 72 hours, in addition to the chemical composition found on their surface. Materials and Methods:  Two brands of mini-implant (Morelli and Neodent) were evaluated; polystyrene was used as a control group (n  =  3). Osteoblasts were cultured on the surface of sterilized mini-implants in a CO2 incubator at different time periods (24, 48, and 72 hours). Osteoblast proliferation was quantified by scanning electron microscopy using up to 5000× magnification, and cell morphology was analyzed by a single observer. For the chemical analysis, spectroscopy X-ray fluorescence was used to identify and quantify chemical components on the surface of the mini-implants. Results:  Two-way ANOVA showed no significant interaction between the factors studied (P  =  0.686). A Tukey test revealed no significant difference in osteoblast proliferation between the mini-implants at all studied periods; however, a difference in cell proliferation was detected between the Neodent and the control group (P  =  .025). For all groups, time had a direct and positive effect on osteoblast proliferation (P &lt; .001). The significant elements present in both brands of mini-implants were titanium, aluminum, vanadium, and iron. Conclusions:  Osteoblast proliferation was present on the mini-implants studied, which increased over time; however, no significant difference between brands was observed. No difference was seen between the mini-implants evaluated in terms of chemical composition. Cell adhesion after 72 hours suggests that areas of bone remodeling can be achieved, thus initiating the process of mini-implant anchorage.


2021 ◽  
pp. 159101992110573
Author(s):  
Naoki Kaneko ◽  
Ariel Takayanagi ◽  
Hamidreza Saber ◽  
Lea Guo ◽  
Satoshi Tateshima

Objective Neuroendovascular procedures rely on successful navigation and stable access to the target vessel. The Stabilizer is a 300 cm long exchange wire with a 0.014 diameter and a soft, flexible stent at the distal end designed to assist with navigation and device delivery. This study aims to assess the efficacy of the Stabilizer for navigation in a variety of challenging environments. Methods The efficacy of the Stabilizer was evaluated using three challenging vascular models: a giant aneurysm model, a severe tortuosity model, and an M1 stenosis model. The Stabilizer was compared with a conventional wire during navigation in each model. Results In the giant aneurysm model, there was no significant difference of success during straightening of a looped wire and significantly higher success rates when advancing an intermediate catheter with the Stabilizer beyond the aneurysm neck compared to a conventional guidewire. The Stabilizer also significantly increased success rates when advancing an intermediate catheter through a model with severe tortuosity compared to a conventional guidewire, as well as exchange maneuver for intracranial stenting in a stenosis model compared to an exchange wire. Conclusions In our experimental model, the Stabilizer significantly improved navigation and device delivery in a variety of challenging settings compared to conventional wires.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Blerim Kamberi ◽  
Donika Bajrami ◽  
Miranda Stavileci ◽  
Shuhreta Omeragiq ◽  
Fatmir Dragidella ◽  
...  

Aim. The purpose of this in vitro study was to assess the antimicrobial efficacy of Biopure MTAD against E. faecalis in contaminated root canals. Materials and Methods. Forty-two single rooted extracted human teeth were inoculated with E. faecalis and incubated for four weeks. The samples were divided in two control and five experimental groups irrigated with 1.5% sodium hypochlorite solution (NaOCl); 3% NaOCl; BioPure MTAD; 1.5% NaOCl/17% EDTA; or 3% NaOCl/17% EDTA. After a one-week incubation, complete disinfection was confirmed by the absence of turbidity in the incubation media. Dentin shavings were taken from samples with no turbidity to verify whether E. faecalis was present in dentin tubules. Results were analyzed statistically using Fisher's exact test, with the level of significance set at . Results. Statistical analysis of the data obtained at Day 7 and after dentin shaving analysis showed that BioPure MTAD had significantly greater antibacterial activity than 1.5% NaOCl, 1.5% NaOCl/17% EDTA and 3% NaOCl/17% EDTA. No significant difference was detected between MTAD and 3% NaOCl. Conclusions. These findings suggest that BioPure MTAD possesses superior bactericidal activity compared with NaOCl and EDTA against E. faecalis.


2016 ◽  
Vol 17 (12) ◽  
pp. 997-1002 ◽  
Author(s):  
Fahad I Alkhudhairy ◽  
Zeeshan H Ahmad

ABSTRACT Introduction Various bulk-fill materials depending on their composition, viscosity, and flow ability have different physical and mechanical properties. The aim of this in vitro study was to determine and compare the shear bond strength and microleakage properties of activa restorative with other bulk-fill restorative materials surefil (SDR), Biodentine, ever X posterior. Materials and methods Forty permanent premolars were selected for shear bond strength, and 20 permanent premolars were selected with class II cavities on mesial and distal side for microleakage. Universal testing device was used to assess the shear bond strength. Microleakage was checked using dye penetration method under a stereomicroscope. Mean and standard deviation values were calculated from the recorded values. Intergroup comparison was done by one-way analysis of variance (ANOVA) followed by pairwise comparison using Tukey honestly significant difference (HSD) post hoc test. Results The mean shear bond strength was highest for SDR surefil followed by Ever X posterior, Bioactive restorative, and Biodentine respectively. In this study, SDR (surefil) showed better shear bond strength and better microleakage properties compared with the other test materials (F = 186.7157, p < 0.05). Conclusion The result of this study showed that flowable and fiber-reinforced composites have better shear bond strength and microleakage properties. Clinical significance Flowable bulk-fill composite resins can be used as dentin substitutes because of its superior properties. How to cite this article Alkhudhairy FI, Ahmad ZH. Comparison of Shear Bond Strength and Microleakage of Various Bulk-fill Bioactive Dentin substitutes: An in vitro study. J Contemp Dent Pract 2016;17(12):997-1002.


2020 ◽  
Vol 11 (2) ◽  
pp. 160-166
Author(s):  
Mohammad Javad Moghaddas ◽  
Horieh Moosavi ◽  
Sara Yaghoubirad ◽  
Nasim Chiniforush

Introduction: The purpose of this study was to compare the effect of the bioactive glass, the glass ionomer, and the Erbium YAG laser as liners on the remineralization of the affected dentin. Methods: The present study was conducted on 64 healthy extracted human molars divided into 4 groups, 1 control group and 3 experimental groups. After artificially inducing dentinal caries lesions, each of the experimental groups was applied to the cavity floor and then restored with a composite. The samples were stored after thermocycling in an incubator for two months. Finally, the hardness of the cavity floor was measured at 3 depths of 20, 50 and 100 μm by the Vickers microhardness tester. The dentin conditions underneath the liners were also evaluated with FESEM. Statistical analysis was performed by two-way ANOVA and the post-hoc Games-Howell test (P<0.05). Results: Among the groups, the lowest microhardness value was in the control group (P<0.05) except at a depth of 100 μm; therefore, there was no significant difference between the control group and the bioactive glass (P>0.05). The laser group had the highest microhardness value, which was significantly different from the control group (P<0.05). There was a significant difference between the laser and bioactive glass (P<0.05), except at a depth of 20 μm. The laser and glass ionomer had only a significant difference at a depth of 100 μm (P<0.05). The microhardness value induced by glass ionomer was higher than bioactive glass, which in no depth was significant (P>0.05). Partial dentinal tubule occlusion was observed with FESEM in each of the experimental groups as compared to the control group. Conclusion: The microhardness values were higher in all groups than in the control group. The laser might be more successful in remineralization than the other ones.


Sign in / Sign up

Export Citation Format

Share Document