Testing Speech Perception with Cochlear Implants Through Digital Audio Streaming in a Virtual Sound Booth: A Feasibility Study

Author(s):  
Chen Chen ◽  
Amy L. Stein ◽  
Michelle L. Hughes ◽  
Hayley R. Morris ◽  
Leonid M. Litvak ◽  
...  

Abstract Objective For patients who have received cochlear implants (CIs), speech-perception testing requires specialized equipment. This limits locations where these services can be provided, which can introduce barriers for provision of care. Providing speech test stimuli directly to the CI via wireless digital audio streaming (DAS) or wired direct audio input (DAI) allows for testing without the need for a sound booth (SB). A few studies have investigated the use of DAI for testing speech perception in CIs, but none have evaluated DAS. The goal of this study was to compare speech perception testing in CI users via DAS versus a traditional SB to determine if differences exist between the two presentation modes. We also sought to determine whether pre-processing the DAS signal with room acoustics (reverberation and noise floor) to emulate the SB environment would affect performance differences between the SB and DAS. Design In Experiment 1, speech perception was measured for monosyllabic words in quiet and sentences in quiet and in noise. Scores were obtained in a SB and compared to those obtained via DAS with unprocessed speech (DAS-U) for 11 adult CI users (12 ears). In Experiment 2, speech perception was measured for sentences in noise, where both the speech and noise stimuli were pre-processed to emulate the SB environment. Scores were obtained for 11 adult CI users (12 ears) in the SB, via DAS-U, and via DAS with the processed speech (DAS-P). Results For Experiment 1, there was no significant difference between SB and DAS-U conditions for words or sentences in quiet. However, DAS-U scores were significantly better than SB scores for sentences in noise. For Experiment 2, there was no significant difference between the SB and DAS-P conditions. Similar to Experiment 1, DAS-U scores were significantly better than SB or DAS-P scores. Conclusions By pre-processing the test materials to emulate the noise and reverberation characteristics of a traditional SB, we can account for differences in speech-perception scores between those obtained via DAS and in a SB.

1981 ◽  
Vol 24 (4) ◽  
pp. 520-525 ◽  
Author(s):  
Bruce L. Plakke ◽  
Daniel J. Orchik ◽  
Daniel S. Beasley

Binaural auditory fusion of 108 children (4, 6, and 8 years old) was studied using three lists of monosyllabic words (WIPI) presented at two sensation levels (30 and 40 dB). The words were processed to produce three bandwidth conditions (100, 300, 600 Hz) and were administered via three presentation modes (binaural fusion 1, diotic, binaural fusion 2). Results showed improved discrimination scores with increasing age, sensation level, and filter bandwidth. Diotic scores were better than binaural fusion scores for the narrower bandwidth conditions, but the diotic enhancement effect was seriously compromised in the widest bandwidth (600 Hz) condition. The results confirmed the contention that prior research results were equivocal due, in large measure, to procedural variability. Methods for reducing such variability and enhancing the clinical viability of binaural fusion tasks are suggested.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


Author(s):  
Shani Dettman ◽  
Dawn Choo ◽  
Agnes Au ◽  
Amy Luu ◽  
Richard Dowell

Purpose This retrospective study aimed to amass large data sets to enable statistical comparisons of communication outcomes for infants receiving cochlear implants (CIs) before 9 months of age compared to groups who received their first CI between 9 months and 3.5 years of age. Method Speech perception scores and experienced clinicians' observations were used to refine the Categories of Auditory Performance Index (CAPI), thus creating its revised version, namely, the CAPI-Revised (CAPI-R). Standardized and criterion-referenced language data were used to create the novel Categories of Linguistic Performance (CLIP). The association between CAPI-R and CLIP data at two time points post implant (at 2 years of device experience and at 5 years of age) was examined in a large unselected cohort stratified for age at first implant: before 9 months (Group 1), between 9 and 12 months (Group 2), between 13 and 18 months (Group 3), between 19 and 24 months (Group 4), between 25 and 30 months (Group 5), between 31 and 36 months (Group 6), and between 37 and 42 months (Group 7). Results CAPI-R medians were 5 at 2 years of device experience, and 6 at 5 years of age. At 2 years of device experience, there was no significant difference in CAPI-R medians for children who received their first CI before 9 months compared to all other age-at-implant groups. At 5 years of age, a significantly better CAPI-R median was demonstrated by Group 1 (CI before 9 months) compared to Groups 4, 5, 6, and 7. CLIP medians were 3 at 2 years of device experience, and at 5 years of age. At 2 years device experience, and at 5 years of age, the Group 1 CLIP medians were significantly better than later age-at-implant groups. Conclusion Median CAPI-R outcomes supported access to CIs before 18 months of age for speech perception, and median CLIP outcomes supported access to CIs before 9 months of age for optimum language development.


2003 ◽  
Vol 14 (10) ◽  
pp. 582-591 ◽  
Author(s):  
Alexandra Weatherby ◽  
Katherine R. Henshall ◽  
Colette M. McKay

The aim of this study was to investigate the effects on speech perception of manipulating filter gains in a cochlear implant speech processor. Five implantees, who use the CI22 implant and Spectra processor manufactured by Cochlear Ltd, participated. Four experimental maps were created that were identical to their clinical map except for the profile of gains across the filters. Experimental gain profiles had rising or falling gains across the frequency range, or emphasized or de-emphasized the middle frequencies, relative to the clinical map. Perception of CNC (consonant-vowel-consonant) words at 70 dB SPL was significantly better with the clinical map than with all experimental maps, whereas at the lower level (60 dB SPL) there was minimal difference between the maps, with the low-frequency emphasis map giving significantly better scores than the high-frequency emphasis map. Perception of sentences at 70 dB SPL with a signal-to-noise ratio of +10 dB was better with the high-frequency emphasis map than with the low-frequency emphasis map. None of these best-conditions, however, were statistically better than the clinical map. The results highlighted the importance of signal audibility for speech perception with cochlear implants.


2003 ◽  
Vol 12 (2) ◽  
pp. 114-124 ◽  
Author(s):  
Lisa Lucks Mendel ◽  
Richard A. Roberts ◽  
Julie H. Walton

The effects of sound field FM amplification (SFA) on speech perception performance were investigated in this 2-year study. Kindergarten children with normal hearing were randomly assigned to a treatment group, which comprised 7 classrooms that had SFA systems installed in them, and to a control group, which comprised another 7 classrooms that did not have any amplification available. The children were followed from the beginning of kindergarten through the end of first grade. Improvements in speech perception performance were measured for both groups, with the treatment group demonstrating progress much sooner than the control group. However, this difference was not apparent by the end of the study. The only significant difference measured between the treatment and control groups was that the treatment group performed significantly better than the control group when the stimuli were presented with SFA for the treatment group and without SFA for the control group. The teachers who used SFA enjoyed using amplification in their classrooms and felt that their students enjoyed using it as well.


Author(s):  
B Demir ◽  
M Yüksel ◽  
A Atılgan ◽  
A Ciprut ◽  
C Batman

Abstract Objective To evaluate the spectral resolution achieved with a cochlear implant in users who were implanted using round window route electrode insertion versus a traditional cochleostomy technique. Methods Twenty-six patients were classified into two groups according to the surgical approach: one group (n = 13) underwent cochlear implantation via the round window technique and the other group (n = 13) underwent surgery via cochleostomy. Results A statistically significant difference was found in spectral ripple discrimination scores between the round window and cochleostomy groups. The round window group performed almost two times better than the cochleostomy group. Differences between Turkish matrix sentence test scores were not statistically significant. Conclusion The spectral ripple discrimination scores of patients who had undergone round window cochlear implant electrode insertion were superior to those of patients whose cochlear implants were inserted using a classical cochleostomy technique.


2019 ◽  
Vol 28 (4) ◽  
pp. 986-992 ◽  
Author(s):  
Lisa R. Park ◽  
Erika B. Gagnon ◽  
Erin Thompson ◽  
Kevin D. Brown

Purpose The aims of this study were to (a) determine a metric for describing full-time use (FTU), (b) establish whether age at FTU in children with cochlear implants (CIs) predicts language at 3 years of age better than age at surgery, and (c) describe the extent of FTU and length of time it took to establish FTU in this population. Method This retrospective analysis examined receptive and expressive language outcomes at 3 years of age for 40 children with CIs. Multiple linear regression analyses were run with age at surgery and age at FTU as predictor variables. FTU definitions included 8 hr of device use and 80% of average waking hours for a typically developing child. Descriptive statistics were used to describe the establishment and degree of FTU. Results Although 8 hr of daily wear is typically considered FTU in the literature, the 80% hearing hours percentage metric accounts for more variability in outcomes. For both receptive and expressive language, age at FTU was found to be a better predictor of outcomes than age at surgery. It took an average of 17 months for children in this cohort to establish FTU, and only 52.5% reached this milestone by the time they were 3 years old. Conclusions Children with normal hearing can access spoken language whenever they are awake, and the amount of time young children are awake increases with age. A metric that incorporates the percentage of time that children with CIs have access to sound as compared to their same-aged peers with normal hearing accounts for more variability in outcomes than using an arbitrary number of hours. Although early FTU is not possible without surgery occurring at a young age, device placement does not guarantee use and does not predict language outcomes as well as age at FTU.


Author(s):  
Hanny Tioho ◽  
Maykel A.J Karauwan

The minimum size of coral transplants, Acropora formosa, was assessed to support their survival and growth. For this, 150 coral fragments of different sizes (5, 10, 15 cm) were transplanted close to the donor colony. Their survivorship and growth were observed for 12 months. At the end of the observation time, 90% of 15 cm-transplanted coral fragments survived, while the others (10cm and 5 cm) did 86% and 82% respectively. The average growth rate of 5 cm-coral fragments was 0.860 cm/month, while 10 and 15 cm-fragments were 0.984 cm/month and 1.108 cm/month respectively. One-way ANOVA showed that there was significant difference (p<0.05) among the three (5, 10, 15 cm) transplant initial sizes in which the longest fragment size tended to survive longer than the smaller one.  However, the smaller transplants grew better than the bigger one, 10.318 cm/year (206%) for 5 cm-transplant, 11.803 cm/year (118%) for 10 cm-transplant, and 13.299 cm/year (89%) for 15 cm-transplant, respectively. Ukuran minimal fragmen karang Acropora formosa yang ditransplantasi diduga untuk mendukung ketahanan hidup dan pertumbuhannya. Untuk itu, 150 fragmen karang ditransplantasi ke lokasi yang berdekatan dengan koloni induknya.  Ketahanan hidup dan pertumbuhan semua fragmen karang yang ditransplantasi diamati selama 12 bulan.  Pada akhir pengamatan, 90% dari fragmen karang berukuran 15 cm yang ditransplantasi dapat bertahan hidup, sedangkan yang lainnya (ukuran 10 cm dan 5 cm) masing-masing sebesar 86% dan 82%.  Rata-rata laju pertumbuhan fragmen karang dengan ukuran awal 5 cm adalah 0,860 cm/bulan, sedangkan ukuran fragmen 10 dan 15 cm masing-masing adalah 0,984 cm/bulan and 1,108 cm/bulan. ANOVA satu arah menunjukkan adanya perbedaan yang nyata (p<0.05) antara ketiga ukuran fragmen yang berbeda, di mana ukuran fragmen karang yang lebih panjang cenderung mempunyai ketahanan hidup yang lebih baik. Namun demikian, ukuran transplant yang lebih kecil memiliki pertumbuhan lebih baik dibandingkan dengan ukuran yang lebih besar, yakni10,318 cm/tahun (206%) untuk transplant berukuran 5 cm, 11,803 cm/tahun (118%) untuk 10 cm, dan 13,299 cm/tahun (89%) untuk ukuran 15 cm.


2017 ◽  
Vol 17 (1) ◽  
pp. 93-98
Author(s):  
Zheng Yue ◽  
Zhang Wen-Cheng ◽  
Wu Ze-Yu ◽  
Fu Chuan-Xiang ◽  
Gao Han ◽  
...  

The purpose of this study was to evaluate the anti-fatigue activity of maca hydroalcoholic extract (ME), which mainly contains macamides and polysaccharides. ME was prepared by circumfluence extraction with enzymatic pre-treatment. Anti-fatigue activity of ME was investigated in weight-loaded forced swimming mice, with pure macamides and commercially available maca tablet as positive control. Compared with normal group, pure macamides treatment group could prolong the swimming time to exhaustion, but there was no statistically significant difference (P > 0.05); while ME (middle-dose and high-dose groups) could effectively prolong the swimming durations (P < 0.05). Supplementation with pure macamides significantly decreased blood lactic acid (BLA), whereas ME significantly increased hepatic glycogen (HG), decreased BLA, and blood urea nitrogen (BUN) compared with those in normal control (P < 0.05). The results suggested that the anti-fatigue effect of ME was better than that of pure macamides, which can be explained by the increase of glycogen storage and the reduction of metabolites accumulation.


Sign in / Sign up