scholarly journals A software-based approach in designing a rooftop bifacial PV system for the North Hall of Residence, IUT

Clean Energy ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 403-422
Author(s):  
Abdullah Al Mehadi ◽  
Misbahul Alam Chowdhury ◽  
Mirza Muntasir Nishat ◽  
Fahim Faisal ◽  
Md Minhajul Islam

Abstract Bifacial rooftop photovoltaic panels appear to be an excellent means of power generation in this era of urbanization, especially for land-limited countries like Bangladesh. This paper presents a software-based approach to design and simulate a bifacial solar-panel-based energy model on the rooftop of the North Hall of Residence of the Islamic University of Technology, Gazipur. This vertically mounted model investigates the feasibility and applicability of such an energy model in a university residence, situated in a load-shedding-prone area. Hence, three prominent software platforms, namely PVSOL, PVsyst and System Advisor Model (SAM), are brought into action and rigorous simulations are performed for three different orientations; promising outcomes are observed in terms of annual energy yield, bifacial gain (BG) and consumption coverage of the grid and PV model. The annual energy demand of the North Hall is ~444 733.5 kWh. The three orientations can generate annually 92 508.62, 94 643.48 and 86 758.94 kWh, respectively. Hence, it is evident that the proposed orientations can supply almost 19–21% of the site’s annual demand. Monthly BG analysis shows an overall increase in energy gain of 13%, 15.6% and 6% for Orientation-1, Orientation-2 and Orientation-3, respectively. A rigorous comparative analysis and deviation analysis among the software results has been accomplished to gain more insight into the feasibility of the proposed system. Thus, we have focused on a detailed software-based estimation of energy production for different orientations of the PV panels, considering several factors, which will provide prior knowledge and assessment before going for hardware implementation in the future.

2020 ◽  
Vol 27 (3) ◽  
pp. 335-346
Author(s):  
Ewa Klugmann-Radziemska ◽  
Małgorzata Rudnicka

AbstractIn the recent years photovoltaic (PV) industry has experienced a major growth, caused by the ever present annual decrease in module production prices and the expanding awareness of the general public in terms of renewable energy. There are numerous ways to implement PV modules as an additional energy source for a building, be it mounted on the rooftop, or building integrated (BIPV). An analysis of BIPV consisting of 8 modules with the power of 250 Wp each was carried out for the building of the Chemistry Faculty of Gdansk University of Technology (GUT). It included monthly irradiance and energy generation values and compared them to data obtained by the means of PV-GIS system, after inserting site specific coordinates. Additional research on the same type of a single module with the power of 270 Wp was conducted to provide more insight in this matter. A comprehensible analysis allows for defining a final conclusion for the decrease in energy yield for GUT BIPV installation. Data outputs are lower than expected based on PV-GIS values, as for the most time the facade mounted PV system experiences partial soft shading from the nearby park. Furthermore, it is not located directly facing south, but rather south-east which does not prompt ideal working conditions.


Electronics ◽  
2021 ◽  
Vol 10 (9) ◽  
pp. 1121
Author(s):  
Kamran Ali Khan Niazi ◽  
Yongheng Yang ◽  
Tamas Kerekes ◽  
Dezso Sera

A reconfiguration technique using a switched-capacitor (SC)-based voltage equalizer differential power processing (DPP) concept is proposed in this paper for photovoltaic (PV) systems at a cell/subpanel/panel-level. The proposed active diffusion charge redistribution (ADCR) architecture increases the energy yield during mismatch and adds a voltage boosting capability to the PV system under no mismatch by connected the available PV cells/panels in series. The technique performs a reconfiguration by measuring the PV cell/panel voltages and their irradiances. The power balancing is achieved by charge redistribution through SC under mismatch conditions, e.g., partial shading. Moreover, PV cells/panels remain in series under no mismatch. Overall, this paper analyzes, simulates, and evaluates the effectiveness of the proposed DPP architecture through a simulation-based model prepared in PSIM. Additionally, the effectiveness is also demonstrated by comparing it with existing conventional DPP and traditional bypass diode architecture.


Environments ◽  
2018 ◽  
Vol 5 (11) ◽  
pp. 119 ◽  
Author(s):  
Alessia Arteconi ◽  
Luca Del Zotto ◽  
Roberto Tascioni ◽  
Khamid Mahkamov ◽  
Chris Underwood ◽  
...  

In this paper, the smart management of buildings energy use by means of an innovative renewable micro-cogeneration system is investigated. The system consists of a concentrated linear Fresnel reflectors solar field coupled with a phase change material thermal energy storage tank and a 2 kWe/18 kWth organic Rankine cycle (ORC) system. The microsolar ORC was designed to supply both electricity and thermal energy demand to residential dwellings to reduce their primary energy use. In this analysis, the achievable energy and operational cost savings through the proposed plant with respect to traditional technologies (i.e., condensing boilers and electricity grid) were assessed by means of simulations. The influence of the climate and latitude of the installation was taken into account to assess the performance and the potential of such system across Europe and specifically in Spain, Italy, France, Germany, U.K., and Sweden. Results show that the proposed plant can satisfy about 80% of the overall energy demand of a 100 m2 dwelling in southern Europe, while the energy demand coverage drops to 34% in the worst scenario in northern Europe. The corresponding operational cost savings amount to 87% for a dwelling in the south and at 33% for one in the north.


2018 ◽  
Vol 49 ◽  
pp. 00024
Author(s):  
Szymon Firląg

The aim of this paper is to present the results of measurements, on the quality of internal and external environment, carried out during the cruise of the tall ship STS Fryderyk Chopin. The cruise took place between 16th and 30th September 2017 as part of the scientific seminar of the Warsaw University of Technology (WUT) on the Wave, addressed to students of the WTU. After leaving the port of Edinburgh, crossing the North Sea, the Danish straits, stops in Copenhagen and Kołobrzeg, the tall ship reached Szczecin after two weeks. The measurements carried out on the deck included the temperature and relative humidity of the indoor air in three cabins and the men’s bathroom. In two cabins, the CO2 concentration was measured additionally. The outdoor temperature, relative humidity and concentration of PM 1.0, PM 2.5 and PM 10 were also measured. The obtained results allowed to assess the quality of the internal environment in accordance with the standards and to analyze the effectiveness of the mechanical ventilation system. Measurements of particulate matter have shown significant differences between outdoor air quality in the open sea and in ports or near major shipping routes. It turned out that the impact of emissions from passing ships using diesel engines is clearly visible.


2015 ◽  
Vol 46 (2) ◽  
pp. 62
Author(s):  
Remo Alessio Malagnino

Electric production from renewable resources, such as solar photovoltaic (PV), is playing an increasingly essential role in the agricultural industry because of the progressive increase in the energy price from fossil fuels and the simultaneous decrease in the income deriving from farming activities. A central issue in the sustainable diffusion of PV technologies is represented by the actual energy efficiency of a PV system. For these reasons, a performance analysis has been carried out in order to assess the potentials offered by different PV plants within a defined geographical context with the aim of investigating the impact of each component has on the PV generator global efficiency and defining the main technical parameters that allow to maximise the annual specific electric energy yield of an architectonically integrated plant, installed in a dairy house, compared to a ground-mounted plant. The annual performances of three grid connected PV plants installed in the same dairy cattle farm have been analysed: two are architectonically integrated plants - <em>i.e.</em>, a rooftop unidirectional and a multi-field systems (both 99 kW<sub>p</sub>) - and the other is a ground-mounted plant (480 kW<sub>p</sub>). Furthermore, the electrical performances, estimated by the photovoltaic geographical information system (PVGIS), developed by the EU Joint Research Centre, and by an analytical estimation procedure (AEP), developed on the basis of a meteo-climatic database related to the records of the nearest weather station and integrated by the components’ technical specifications, have been compared with the actual yields. The best annual performance has been given by the ground-mounted PV system, with an actual increase of 26% and in the range of 6÷12% according to different estimations, compared to the integrated systems, which were globally less efficient (average total loss of 26÷27% compared to 24% of the ground-mounted system). The AEP and PVGIS software estimates showed a good level of reliability for mean deviations between the annual actual and estimated electrical power yields have been equal to 11.5% for each PV system given the actual irradiation’ s uncertainty during the examined year. The main technical parameters, crucial to maximise the energy yield from a ground-mounted PV system to an integrated one, have been identified in the Tilt and Azimuth angles. Indeed, once a variance of 3÷4% in the global efficiency has been confirmed when the type of PV system is changed, in the case of the unidirectional integrated PV plant, the high roof pitch and the almost South orientation guarantee a solar energy increase up to 18% higher than that obtainable on the horizontal plane and similar to the increase estimated for the ground-mounted generator (+20%). Hence, integrated PV systems, besides reaching the same levels of energy efficiency as those ground-mounted, are also more <em>sustainable</em> than the latter. This is true providing that there are both a suitable orientation and an accurate design, especially to prevent the PV panels’ warming during summer, on an already available surface that is, however, functional to the roof’s architecture.


2021 ◽  
Vol 13 (0) ◽  
pp. 1-6
Author(s):  
Rasa Džiugaitė-Tumėnienė ◽  
Domas Madeikis

The high share of global energy costs to create an indoor climate has been of increasing interest to the global community for several decades and is increasingly the focus of policy. This paper analyses the energy performance gap between actual energy consumption and energy demand obtained during the dynamic energy simulation and building certification. To identify the energy performance gap, an existing office of energy efficiency class B was selected as a case study. The simulation program IDA Indoor Climate and Energy was used to create a dynamic energy model, based on the designed documentation and the actual indoor climate parameters recorded by the building management system. The results of the case study showed that the accuracy and reliability of the results presented by the dynamic energy model of the building directly depend on the assumptions. The correct values of the internal heat gains, indoor climate parameters, human behavior, air quality levels at different times of the day and season, HVAC system operation parameters and operation modes, specific fan powers of ventilation systems, the seasonal energy efficiency of cooling equipment and characteristics of sun protection measures have to be selected.


2017 ◽  
Vol 31 (2) ◽  
pp. 209-219 ◽  
Author(s):  
Ronggo Sadono ◽  
Hartono Hartono ◽  
Mochammad Maksum Machfoedz ◽  
Setiaji Setiaji

Volcanic eruption is one of the natural factors that affect land cover changes. This study aimed to monitor land cover changes using a remote sensing approach in Cangkringan Sub-district, Yogyakarta, Indonesia, one of the areas most vulnerable to Mount Merapi eruption. Three satellite images, dating from 2001, 2006 and 2011, were used as main data for land cover classification based on a supervised classification approach. The land cover detection analysis was undertaken by overlaying the classification results from those images. The results show that the dominant land cover class is annual crops, covering 40% of the study area, while the remaining 60% consists of forest cover types, dryland farming, paddy fields, settlements, and bare land. The forests were distributed in the north, and the annual crops in the middle of the study area, while the villages and the rice fields were generally located in the south. In the 2001–2011 period, forests were the most increased land cover type, while annual crops decreased the most, as a result of the eruption of Mount Merapi in 2010. Such data and information are important for the local government or related institutions to formulate Detailed Spatial Plans (RDTR) in the Disaster-Prone Areas (KRB).


2010 ◽  
Vol 16 (3) ◽  
pp. 345-351 ◽  
Author(s):  
Violeta Motuzienė ◽  
Egidijus Saulius Juodis

The number of office buildings with highly fenestrated facades is currently increasing in Lithuania and neighboring countries. Highly fenestrated facades reduce energy consumption for lighting and simultaneously increase energy consumption for heating, cooling, air conveying and may cause thermal and visual discomfort. Pursuing to reduce negative effects of the highly glazed facade, special glasses are frequently used. However, such windows usually increase demand for lighting energy. Therefore, when making early decisions about glazing the building, it is important to have a complex evaluation of energy demand related to the specific case. The paper presents the results of analysis made using energy simulation tools. The obtained results have shown that when shading is not applied, the north is the most energy efficient orientation to glazing for an air conditioned office building in cool climate zones like Lithuania. The most energy efficient window‐to‐wall ratios (WWR) for the south, east and west oriented façade are 20%, whereas for the north it makes 20–40%. However, such WWR values do not satisfy standard requirements for day lighting. Santrauka Pastaraisiais metais Lietuvoje ir kaimyninese šalyse daugeja administracines paskirties pastatu, kuriu dauguma išoriniu atitvaru yra skaidrios. Didesnis istiklinimo plotas lemia mažesnius energijos poreikius apšvietimui, tačiau didina šildymo ir vesinimo sistemu energijos poreikius, sukelia šilumini bei vizualini diskomforta. Neigiamai dideliu skaidriu atitvaru itakai sumažinti naudojami tamsinti ir kitu specialiu charakteristiku stiklai, tačiau tai savo ruožtu didina energijos poreiki apšvietimui. Todel, priimant sprendimus del pastato istiklinimo, svarbu prieš tai kompleksiškai išnagrineti konkretaus sprendimo itaka pastato energijos poreikiams. Straipsnyje pateikiama modeliuojant gautu rezultatu analize. Rezultatai parode, kad vesaus klimato šalyse, kurioms priklauso ir Lietuva, kondicionuojamu administraciniu pastatu fasadu, kai nenaudojamos apsaugos nuo saules priemones, energiškai efektyviausias istiklinimas yra i šiaures puse. Energiškai efektyviausias santykinis fasado istiklinimo plotas pietines, rytines ir vakarines orientacijos fasadams yra 20 %, o šiaurines ‐ 20–40 %. Tačiau tokie istiklinimo plotai neatitinka norminiu natūralaus apšvietimo reikalavimu.


2021 ◽  
Vol 3 (1) ◽  
pp. 45-49
Author(s):  
Muhammad Umar Maqbool ◽  
Arslan Dawood Butt ◽  
Abdul Rauf Bhatti ◽  
Yawar Ali Sheikh ◽  
Muhammad Waleed Asif

This work performs a quantitative assessment of the impact of rooftop PV installation on building’s net energy demand using model of roof structure and steady state thermal simulations. For this purpose, roof structure typically used in Faisalabad, Pakistan is modeled with and without the shading effect due to a 395 W commercial rooftop PV setup. The simulated parameters include the impact of PV module’s dimensions, mounting position/angle alongside roof size and ambient conditions on heat load of air-conditioning system to maintain a temperature of 25 °C within building’s top floor. During the daylight hours of July, the heat load added by the roof on average reduces from 150.87 BTU/h/m2 without PV to 118.16 BTU/h/m2 with PV structure. This 20.05% reduction in energy demand has been achieved with July’s maximum daytime solar and infrared irradiances of 792.2 W/m2 and 466 W/m2 recorded at an average ambient temperature of 35.5 °C and wind speed of 2.75 m/s. This study provides valuable data on optimization of roof layer structure during building’s construction in anticipation of PV system installation at a later stage. Also developed techniques/methods to reduce building’s energy budget due to PV installation, can be valuable input for construction industry as well.


Author(s):  
Megashnee Munsamy ◽  
Arnesh Telukdarie ◽  
Pavitra Dhamija

Logistics activities are significant energy consumers and known contributors to GHG emissions, hence optimisation of logistics energy demand is of critical importance. The onset of the fourth Industrial revolution delivers significant technological opportunities for logistics optimisation with additional benefits in logistics energy optimisation. This research propositions a business process centric logistics model based on Industry 4.0. A Logistics 4.0 architecture is developed comprising Industry 4.0 technologies and associated enablers. The Industry 4.0 architecture components are validated by conducting a Systematic Literature Review on Industry 4.0 and logistics. Applying the validated Logistics 4.0 architecture to a cyber physical logistics energy model, based on the digitalisation of business processes, a comprehensive simulation is developed identified as the Logistic 4.0 Energy Model. The model simulates the technological impact of Industry 4.0 on a logistics network. The model generates energy and CO2 emission values for “as-is” and “to-be” Industry 4.0 scenarios.


Sign in / Sign up

Export Citation Format

Share Document