Flow rate variability from electronic infusion devices

1988 ◽  
Vol 16 (9) ◽  
pp. 888-891 ◽  
Author(s):  
JILL C. STULL ◽  
ALLEN ERENBERG ◽  
RICHARD D. LEFF
Keyword(s):  
1995 ◽  
Vol 8 (2) ◽  
pp. 32-33
Author(s):  
Susanne L. Lewer ◽  
Ian C. Baldwin ◽  
Dennis O. Rafter ◽  
Graeme K. Hart

Author(s):  
Andjar Pudji Pudji ◽  
Anita Miftahul Maghfiroh ◽  
Nuntachai Thongpance

Infusion devices are the basis for primary health care, that is to provide medicine, nutrition, and hydration to patients. One of the infusion devices is a syringe pump and an infusion pump. This device is very important to assist the volume and flow that enters the patient's body, especially in situations related to neonatology or cancer treatment. Therefore, a comparison tool is needed to see whether the equipment is used or not. The purpose of this research is to make an infusion device analyzer (IDA) design with a flow rate parameter. The contribution of this research is that the tool can calculate the correct value of the flow rate that comes out of the infusion pump and syringe pump. The water released by the infusion pump or syringe pump will be converted into droplets which are then detected by the sensor. This tool uses an infrared sensor and a photodiode. The results obtained by the sensor will come by Arduino nano and code it to the 16x2 Character Liquid Crystal Display (LCD) and can be stored on an SD Card so that it can be analyzed further. In setting the flow rate for the syringe pump of 100 mL / hour, the error value is 3.9, 50 ml / hour 0.02, 20 mL / hour 0.378, 10 mL / hour 0.048, and 5 mL / hour 0.01. The results show that the average error of the syringe pump performance read by the module is 0.87. The results obtained from this study can be implemented for the calibration of the infusion pump and the syringe pump so that it can be determined whether the device is suitable or not


1988 ◽  
Vol 22 (9) ◽  
pp. 687-690 ◽  
Author(s):  
Elizabeth A. Farrington ◽  
Jill C. Stull ◽  
Richard D. Leff

Alterations in response to pharmacological agents have been attributed to flow rate variation produced by intravenous infusion devices during drug delivery. A wide range of variation has been shown to occur with large-volume infusion devices. The intent of this investigation was to examine flow variation resulting from the use of selected small-volume syringe and mobile infusion devices and determine whether these devices have greater flow continuity than large-volume infusion pumps. Each syringe and mobile infusion device delivered iv fluid at three flow rates (1, 5, and 10 ml/h). The effusate was collected in a tared beaker and serial weights were measured every ten seconds using a computerized, gravimetric technique. Accuracy, continuity, and pattern of flow were determined for each of the syringe and mobile infusion devices. All of the devices produced accurate flow, within ± 10 percent of the desired 5 and 10 ml/h rates. However, the actual iv flow rate ranged from 53 to 93 percent for the 1 ml/h rate. Continuity and pattern of flow resulting from each device were diverse. When compared with large-volume, microrate infusion devices, no significant differences could be observed. Therefore, no clear advantage to delivering drug solutions on a continuous basis can be expected from the use of small-volume devices. Specific infusion devices may be preferable for certain clinical applications; flow continuity data may be valuable when selecting an infusion device.


Author(s):  
A. Engel ◽  
A. Holzenburg ◽  
K. Stauffer ◽  
J. Rosenbusch ◽  
U. Aebi

Reconstitution of solubilized and purified membrane proteins in the presence of phospholipids into vesicles allows their functions to be studied by simple bulk measurements (e.g. diffusion of differently sized solutes) or by conductance measurements after transformation into planar membranes. On the other hand, reconstitution into regular protein-lipid arrays, usually forming at a specific lipid-to-protein ratio, provides the basis for determining the 3-dimensional structure of membrane proteins employing the tools of electron crystallography.To refine reconstitution conditions for reproducibly inducing formation of large and highly ordered protein-lipid membranes that are suitable for both electron crystallography and patch clamping experiments aimed at their functional characterization, we built a flow-dialysis device that allows precise control of temperature and flow-rate (Fig. 1). The flow rate is generated by a peristaltic pump and can be adjusted from 1 to 500 ml/h. The dialysis buffer is brought to a preselected temperature during its travel through a meandering path before it enters the dialysis reservoir. A Z-80 based computer controls a Peltier element allowing the temperature profile to be programmed as function of time.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


2012 ◽  
Vol 21 (1) ◽  
pp. 15-21
Author(s):  
Merete Bakke ◽  
Allan Bardow ◽  
Eigild Møller

Severe drooling is associated with discomfort and psychosocial problems and may constitute a health risk. A variety of different surgical and non-surgical treatments have been used to diminish drooling, some of them with little or uncertain effect and others more effective but irreversible or with side effects. Based on clinical evidence, injection with botulinum toxin (BTX) into the parotid and submandibular glands is a useful treatment option, because it is local, reversible, and with few side effects, although it has to be repeated. The mechanism of BTX is a local inhibition of acetylcholine release, which diminishes receptor-coupled secretion and results in a flow rate reduction of 25–50% for 2–7 months.


Author(s):  
K. Subramanyam ◽  
Dr. P. Subhash Babu

Obesity has become one of the major health issues in India. WHO defines obesity as “A condition with excessive fat accumulation in the body to the extent that the health and wellbeing are adversely affected”. Obesity results from a complex interaction of genetic, behavioral, environmental and socioeconomic factors causing an imbalance in energy production and expenditure. Peak expiratory flow rate is the maximum rate of airflow that can be generated during forced expiratory manoeuvre starting from total lung capacity. The simplicity of the method is its main advantage. It is measured by using a standard Wright Peak Flow Meter or mini Wright Meter. The aim of the study is to see the effect of body mass index on Peak Expiratory Flow Rate values in young adults. The place of a study was done tertiary health care centre, in India for the period of 6 months. Study was performed on 80 subjects age group 20 -30 years, categorised as normal weight BMI =18.5 -24.99 kg/m2 and overweight BMI =25-29.99 kg/m2. There were 40 normal weight BMI (Group A) and 40 over weight BMI (Group B). BMI affects PEFR. Increase in BMI decreases PEFR. Early identification of risk individuals prior to the onset of disease is imperative in our developing country. Keywords: BMI, PEFR.


Author(s):  
B.S. Soroka ◽  
V.V. Horupa

Natural gas NG consumption in industry and energy of Ukraine, in recent years falls down as a result of the crisis in the country’s economy, to a certain extent due to the introduction of renewable energy sources along with alternative technologies, while in the utility sector the consumption of fuel gas flow rate enhancing because of an increase the number of consumers. The natural gas is mostly using by domestic purpose for heating of premises and for cooking. These items of the gas utilization in Ukraine are already exceeding the NG consumption in industry. Cooking is proceeding directly in the living quarters, those usually do not meet the requirements of the Ukrainian norms DBN for the ventilation procedures. NG use in household gas stoves is of great importance from the standpoint of controlling the emissions of harmful components of combustion products along with maintenance the satisfactory energy efficiency characteristics of NG using. The main environment pollutants when burning the natural gas in gas stoves are including the nitrogen oxides NOx (to a greater extent — highly toxic NO2 component), carbon oxide CO, formaldehyde CH2O as well as hydrocarbons (unburned UHC and polyaromatic PAH). An overview of environmental documents to control CO and NOx emissions in comparison with the proper norms by USA, EU, Russian Federation, Australia and China, has been completed. The modern designs of the burners for gas stoves are considered along with defining the main characteristics: heat power, the natural gas flow rate, diameter of gas orifice, diameter and spacing the firing openings and other parameters. The modern physical and chemical principles of gas combustion by means of atmospheric ejection burners of gas cookers have been analyzed from the standpoints of combustion process stabilization and of ensuring the stability of flares. Among the factors of the firing process destabilization within the framework of analysis above mentioned, the following forms of unstable combustion/flame unstabilities have been considered: flashback, blow out or flame lifting, and the appearance of flame yellow tips. Bibl. 37, Fig. 11, Tab. 7.


Sign in / Sign up

Export Citation Format

Share Document