scholarly journals Electrochemical properties of 316L stainless steel with culturing L929 fibroblasts

2005 ◽  
Vol 3 (9) ◽  
pp. 495-505 ◽  
Author(s):  
Sachiko Hiromoto ◽  
Takao Hanawa

Potentiodynamic polarization and impedance tests were carried out on 316L stainless steel with culturing murine fibroblast L929 cells to elucidate the corrosion behaviour of 316L steel with L929 cells and to understand the electrochemical interface between 316L steel and cells, respectively. Potential step test was carried out on 316L steel with type I collagen coating and culturing L929 cells to compare the effects of collagen and L929 cells. The open-circuit potential of 316L steel slightly shifted in a negative manner and passive current density increased with cells, indicating a decrease in the protective ability of passive oxide film. The pitting potential decreased with cells, indicating a decrease in the pitting corrosion resistance. In addition, a decrease in diffusivity at the interface was indicated from the decrease in the cathodic current density and the increase in the diffusion resistance parameter in the impedance test. The anodic peak current in the potential step test decreased with cells and collagen. Consequently, the corrosion resistance of 316L steel decreases with L929 cells. In addition, collagen coating would provide an environment for anodic reaction similar to that with culturing cells.

2022 ◽  
Vol 60 (1) ◽  
pp. 46-52
Author(s):  
Young Woo Seo ◽  
Chan Yang Kim ◽  
Bo Kyung Seo ◽  
Won Sub Chung

This study evaluated changes in delta-ferrite content depending on the preheating of AISI 316L stainless steel. We also determined the reasons for the variation in delta-ferrite content, which affects corrosion resistance. Changes in delta-ferrite content after preheating was confirmed using a Feritscope, and the microstructure was analyzed using optical microscopy (OM). We found that the delta-ferrite microstructure size decreased when preheating time was increased at 1295 oC, and that the delta-ferrite content could be controlled through preheating. Potentiodynamic polarization test were carried out in NaCl (0.5 M) + H2SO4 (0.5 M) solution, and it was found that higher delta-ferrite content resulted in less corrosion potential and passive potential. To determine the cause, an analysis was conducted using energy-dispersive spectroscopy (EDS), which confirmed that higher delta-ferrite content led to weaker corrosion resistance, due to Cr degradation at the delta-ferrite and austenite boundaries. The degradation of Cr on the boundaries between austenite and delta-ferrite can be explained by the difference in the diffusion coefficient of Cr in the ferrite and austenite. A scanning electron microscopy (SEM) analysis of material used for actual semiconductor piping confirmed that corrosion begins at the delta-ferrite and austenite boundaries. These results confirm the need to control delta-ferrite content in AISI 316L stainless steel used for semiconductor piping.


2007 ◽  
Vol 561-565 ◽  
pp. 1459-1462 ◽  
Author(s):  
Sachiko Hiromoto

Understanding of interaction reactions between materials and tissue in the body is necessary for the success of implant devices. Impedance and polarisation properties at the interface on 316L stainless steel and pure Ti under cell culture environment of fibroblast L929 or with collagen coating were examined. Limitation of mass diffusion at the interface by cell bodies and extracellular matrix is probably a corrosion factor of the presence of cells, which causes the decrease of protectiveness of passive film on 316L steel. Surface composition of 316L steel and Ti formed with L929 was compared with that formed in human body. Similar elements were detected on the surface formed in both the environments. The precipitated sulphur on the surface formed under cell culture and in the human body appears to be originated from proteins that might be produced by cells.


2019 ◽  
Vol 25 (3) ◽  
pp. 566-580 ◽  
Author(s):  
Edyta Lyczkowska-Widlak ◽  
Pawel Lochynski ◽  
Ginter Nawrat ◽  
Edward Chlebus

Purpose This paper aims to present the way of modifying surfaces of 316L stainless steel elements that were manufactured in the selected laser melting (SLM) technology and then subjected to mechanical and electrolytic processing (electropolishing [EP]). The surface of the as-generated and commercial produced parts was modified by grinding and EP, and the results were compared. The authors also present an example of the application of EP for the final processing of a sample technological model – an initial prototype of a 316L steel implant manufactured in the SLM technology. Design/methodology/approach The analyzed properties included surface topography, roughness, resistance to corrosion, microhardness and the chemical composition of the surface before and after EP. The roughness described with the Ra, Rt and Rz was determined before and after EP of samples manufactured from 316L steel with use of traditional methods and additive technologies. Findings EP provides us with the opportunity to process elements with a complex structure, which would not be possible with use of other methods (such as milling or grinding). Depending on the expected final surface of elements after the SLM process, it is possible to reduce the surface roughness with the use of EP (for t = 20 min, Ra = 3.53 ± 0.37 µm and for t = 40 min, Ra = 3.23 ± 0.22 µm) or mechanical processing and EP (for t = 4 min, Ra = 0.13 ± 0.02 µm). The application of the EP method to elements made from 316L steel, in a bath consisting of sulfuric acid (VI), H2SO4 (35 Vol.%), phosphoric acid (V), H3PO4 (60.5 Vol.%) and triethanolamine 99 per cent (4.5 Vol.%), allows us to improve the surface smoothness and to obtain a value of the Ra parameter ranging from 0.11 to 0.15 µm. The application of a current density of 20 A/dm2 and a bath temperature of 55ºC results in an adequate smoothing of the surface (Ra < 0.16 µm) for both cold rolled and SLM elements after grinding. The application of EP, to both cold rolled elements and those after SLM, considerably improves the resistance to corrosion. The results of potentiodynamic corrosion resistance tests (jkor, EKA and Vp) of the 316L stainless steel samples demonstrate that the values of Vp for elements subjected to EP (commercial material: 1.3·10-4 mm/year, SLM material: 3.5·10-4 mm/year) are lower than for samples that were only ground (commercial material: 4.0·10-4 mm/year, SLM material: 9.6·10-4 mm/year). The microhardness was found to be significantly higher in elements manufactured using SLM technology than in those cold rolled and ground. The ground 316L steel samples were characterized by a microhardness of 318 HV (cold rolled) and 411 HV (SLM material), whereas the microhardness of samples subjected to EP was 230 HV (commercial material) and 375 HV (SLM material). Originality/value The 316L samples were built by SLM method. The surface of the SLM samples was modified by EP. Surface morphological changes after EP were studied using optical methods. Potentiodynamic tests enabled to notice changes in the corrosion resistance of 316L. Microhardness results after electropolished 316L stainless steel were shown. The chemical composition of 316L surface samples was presented. The smoothening of the surface amounted to Ra = 0.16 µm.


Alloy Digest ◽  
1995 ◽  
Vol 44 (6) ◽  

Abstract BioDur 316LS stainless steel is a modified version of Type 316L stainless steel to improve corrosion resistance for surgical implant applications. The alloy is vacuum arc remelted. This datasheet provides information on composition, physical properties, hardness, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-596. Producer or source: Carpenter.


Alloy Digest ◽  
2015 ◽  
Vol 64 (7) ◽  

Abstract EnduraMet 316LN stainless is a nitrogen strengthened version of Type 316L stainless steel. This datasheet provides information on composition, physical properties, and tensile properties as well as fracture toughness. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-1219. Producer or source: Carpenter Technology Corporation.


Author(s):  
S. Kuroda ◽  
T. Fukushima ◽  
T. Kodama ◽  
M. Sasaki

Abstract 316L stainless steel and Hastelloy C alloy powders were sprayed by an HVOF apparatus onto mild steel substrates. The microstructure, pore size distribution, composition and corrosion resistance of thus obtained coatings were evaluated experimentally. Corrosion resistance in sea-water was examined by monitoring the impedance and corrosion potential of samples immersed in artificial sea-water at 300 K over a period of more than 3 months and also by polarization measurement. It was found that the stainless coatings composed mainly of plastically deformed particles and some splats which were molten at the impact. By increasing the combustion pressure, the porosity as measured by mercury porosimeter could be reduced to below 1%. In comparison, Hastelloy C deposits sprayed under the standard condition were so dense that its porosity could not be measured by the porosimeter. The polarization curve and the results of impedance monitoring both exemplified that the Hastelloy C coatings possess much superior corrosion resistance to the stainless coatings in sea-water, which was attributed to the higher density and better adhesion of the Ni-base alloy coatings.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6790
Author(s):  
Viera Zatkalíková ◽  
Juraj Halanda ◽  
Dušan Vaňa ◽  
Milan Uhríčik ◽  
Lenka Markovičová ◽  
...  

Plasma immersion ion implantation (PIII) of nitrogen is low-temperature surface technology which enables the improvement of tribological properties without a deterioration of the corrosion behavior of austenitic stainless steels. In this paper the corrosion properties of PIII-treated AISI 316L stainless steel surfaces are evaluated by electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PP) and exposure immersion tests (all carried out in the 0.9 wt. % NaCl solution at 37 ± 0.5 °C) and compared with a non-treated surface. Results of the three performed independent corrosion tests consistently confirmed a significant increase in the corrosion resistance after two doses of PIII nitriding.


1991 ◽  
Vol 49 (1-3) ◽  
pp. 83-86 ◽  
Author(s):  
J.H. Hsieh ◽  
R. Lee ◽  
R.A. Erck ◽  
G.R. Fenske ◽  
Y.Y. Su ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document