scholarly journals High resolution of colour vision, but low contrast sensitivity in a diurnal raptor

2018 ◽  
Vol 285 (1885) ◽  
pp. 20181036 ◽  
Author(s):  
Simon Potier ◽  
Mindaugas Mitkus ◽  
Almut Kelber

Animals are thought to use achromatic signals to detect small (or distant) objects and chromatic signals for large (or nearby) objects. While the spatial resolution of the achromatic channel has been widely studied, the spatial resolution of the chromatic channel has rarely been estimated. Using an operant conditioning method, we determined (i) the achromatic contrast sensitivity function and (ii) the spatial resolution of the chromatic channel of a diurnal raptor, the Harris's hawk Parabuteo unicinctus . The maximal spatial resolution for achromatic gratings was 62.3 c deg −1 , but the contrast sensitivity was relatively low (10.8–12.7). The spatial resolution for isoluminant red-green gratings was 21.6 c deg −1 —lower than that of the achromatic channel, but the highest found in the animal kingdom to date. Our study reveals that Harris's hawks have high spatial resolving power for both achromatic and chromatic vision, suggesting the importance of colour vision for foraging. By contrast, similar to other bird species, Harris's hawks have low contrast sensitivity possibly suggesting a trade-off with chromatic sensitivity. The result is interesting in the light of the recent finding that double cones—thought to mediate high-resolution vision in birds—are absent in the central fovea of raptors.

Sensors ◽  
2020 ◽  
Vol 20 (22) ◽  
pp. 6416
Author(s):  
Sunghoon Choi ◽  
Chang-Woo Seo ◽  
Bo Kyung Cha

In this study, the effect of filter schemes on several low-contrast materials was compared using standard and ultra-high-resolution (UHR) cone-beam computed tomography (CBCT) imaging. The performance of the UHR-CBCT was quantified by measuring the modulation transfer function (MTF) and the noise power spectrum (NPS). The MTF was measured at the radial location around the cylindrical phantom, whereas the NPS was measured in the eight different homogeneous regions of interest. Six different filter schemes were designed and implemented in the CT sinogram from each imaging configuration. The experimental results indicated that the filter with smaller smoothing window preserved the MTF up to the highest spatial frequency, but larger NPS. In addition, the UHR imaging protocol provided 1.77 times better spatial resolution than the standard acquisition by comparing the specific spatial frequency (f50) under the same conditions. The f50s with the flat-top window in UHR mode was 1.86, 0.94, 2.52, 2.05, and 1.86 lp/mm for Polyethylene (Material 1, M1), Polystyrene (M2), Nylon (M3), Acrylic (M4), and Polycarbonate (M5), respectively. The smoothing window in the UHR protocol showed a clearer performance in the MTF according to the low-contrast objects, showing agreement with the relative contrast of materials in order of M3, M4, M1, M5, and M2. In conclusion, although the UHR-CBCT showed the disadvantages of acquisition time and radiation dose, it could provide greater spatial resolution with smaller noise property compared to standard imaging; moreover, the optimal window function should be considered in advance for the best UHR performance.


Author(s):  
Graham R. Martin

Vision is the primary source of information about the environments in which birds live. But vision is not ‘all-seeing’; it is subject to many constraints, trade-offs, and compromises. Furthermore, the basic components of eyes (optics, image analysing systems, and eye positions) have been subject to intense and persistent natural selection which has resulted in eyes whose capacities are tuned in many and subtle ways to the perceptual challenges posed by life in different environments. Colour vision, spatial resolution, contrast sensitivity, absolute sensitivity, and visual fields all differ markedly between species. Even two birds with eyes that appear very similar may have quite different bird’s eye views, and all birds have a different world view from our own. Knowledge of these differences is vital for understanding the behaviours of birds. While vision provides key information only rarely is it sufficient to guide behaviour, information from other senses must come into play.


2021 ◽  
Author(s):  
Alison R Irwin ◽  
Suzanne T Williams ◽  
Daniel I Speiser ◽  
Nicholas W Roberts

All species within the conch snail family Strombidae possess large camera-type eyes that are surprisingly well-developed compared to those found in most other gastropods. Although these eyes are known to be structurally complex, very little research on their visual function has been conducted. Here, we use isoluminant expanding visual stimuli to measure the spatial resolution and contrast sensitivity of a strombid, Conomurex luhuanus. Using these stimuli, we show that this species responds to objects as small as 1.06° in its visual field. We also show that C. luhuanus responds to Michelson contrasts of 0.07, a low contrast sensitivity between object and background. The defensive withdrawal response elicited by visual stimuli of such small angular size and low contrast suggests that conch snails may use spatial vision for the early detection of potential predators. We support these findings with morphological estimations of spatial resolution of 1.04 ± 0.14°. These anatomical data therefore agree with the behavioural measures and highlight the benefits of integrating morphological and behavioural approaches in animal vision studies. Furthermore, using contemporary imaging techniques including serial block-face scanning electron microscopy (SBF-SEM), in conjunction with transmission electron microscopy (TEM), we found that C. luhuanus have more complex retinas, in terms of cell type diversity, than previous studies of the group have discovered using TEM alone. We found the C. luhuanus retina is comprised of six cell types, including a newly identified ganglion cell and accessory photoreceptor, rather than the previously described four cell types.


Author(s):  
A. V. Crewe

The high resolution STEM is now a fact of life. I think that we have, in the last few years, demonstrated that this instrument is capable of the same resolving power as a CEM but is sufficiently different in its imaging characteristics to offer some real advantages.It seems possible to prove in a quite general way that only a field emission source can give adequate intensity for the highest resolution^ and at the moment this means operating at ultra high vacuum levels. Our experience, however, is that neither the source nor the vacuum are difficult to manage and indeed are simpler than many other systems and substantially trouble-free.


Author(s):  
Mihir Parikh

It is well known that the resolution of bio-molecules in a high resolution electron microscope depends not just on the physical resolving power of the instrument, but also on the stability of these molecules under the electron beam. Experimentally, the damage to the bio-molecules is commo ly monitored by the decrease in the intensity of the diffraction pattern, or more quantitatively by the decrease in the peaks of an energy loss spectrum. In the latter case the exposure, EC, to decrease the peak intensity from IO to I’O can be related to the molecular dissociation cross-section, σD, by EC = ℓn(IO /I’O) /ℓD. Qu ntitative data on damage cross-sections are just being reported, However, the microscopist needs to know the explicit dependence of damage on: (1) the molecular properties, (2) the density and characteristics of the molecular film and that of the support film, if any, (3) the temperature of the molecular film and (4) certain characteristics of the electron microscope used


Author(s):  
S. Saito ◽  
H. Todokoro ◽  
S. Nomura ◽  
T. Komoda

Field emission scanning electron microscope (FESEM) features extremely high resolution images, and offers many valuable information. But, for a specimen which gives low contrast images, lateral stripes appear in images. These stripes are resulted from signal fluctuations caused by probe current noises. In order to obtain good images without stripes, the fluctuations should be less than 1%, especially for low contrast images. For this purpose, the authors realized a noise compensator, and applied this to the FESEM.Fig. 1 shows an outline of FESEM equipped with a noise compensator. Two apertures are provided gust under the field emission gun.


Author(s):  
Benjamin M. Siegel

The potential advantages of high voltage electron microscopy for extending the limits of resolution and contrast in imaging low contrast objects, such as biomolecular specimens, is very great. The results of computations will be presented showing that at accelerating voltages of 500-1000 kV it should be possible to achieve spacial resolutions of 1 to 1.5 Å and using phase contrast imaging achieve adequate image contrast to observe single atoms of low atomic number.The practical problems associated with the design and utilization of the high voltage instrument are, optimistically, within the range of competence of the state of the art. However, there are some extremely important and critical areas to be systematically investigated before we have achieved this competence. The basic electron optics of the column required is well understood, but before the full potential of an instrument capable of resolutions of better than 1.5 Å are realized some very careful development work will be required. Of great importance for the actual achievement of high resolution with a high voltage electron microscope is the fundamental limitation set by the characteristics of the high voltage electron beam that can be obtained from the accelerator column.


Author(s):  
P. A. Marsh ◽  
T. Mullens ◽  
D. Price

It is possible to exceed the guaranteed resolution on most electron microscopes by careful attention to microscope parameters essential for high resolution work. While our experience is related to a Philips EM-200, we hope that some of these comments will apply to all electron microscopes.The first considerations are vibration and magnetic fields. These are usually measured at the pre-installation survey and must be within specifications. It has been our experience, however, that these factors can be greatly influenced by the new facilities and therefore must be rechecked after the installation is completed. The relationship between the resolving power of an EM-200 and the maximum tolerable low frequency interference fields in milli-Oerstedt is 10 Å - 1.9, 8 Å - 1.4, 6 Å - 0.8.


Author(s):  
Keiichi Tanaka

With the development of scanning electron microscope (SEM) with ultrahigh resolution, SEM became to play an important role in not only cytology but also molecular biology. However, the preparation methods observing tiny specimens with such high resolution SEM are not yet established.Although SEM specimens are usually coated with metals for getting electrical conductivity, it is desirable to avoid the metal coating for high resolution SEM, because the coating seriously affects resolution at this level, unless special coating techniques are used. For avoiding charging effect without metal coating, we previously reported a method in which polished carbon plates were used as substrate. In the case almost all incident electrons penetrate through the specimens and do not accumulate in them, when the specimens are smaller than 10nm. By this technique some biological macromolecules including ribosomes, ferritin, immunoglobulin G were clearly observed.Unfortunately some other molecules such as apoferritin, thyroglobulin and immunoglobulin M were difficult to be observed only by the method, because they had very low contrast and were easily damaged by electron beam.


Sign in / Sign up

Export Citation Format

Share Document