scholarly journals Spectroscopic Assessment of Normal Cortical Bone: Differences in Relation to Bone Site and Sex

2010 ◽  
Vol 10 ◽  
pp. 402-412 ◽  
Author(s):  
Nikolaos Kourkoumelis ◽  
Margaret Tzaphlidou

Bone is a highly complex, composite tissue and its properties normally vary with age, type, and disorders. Fourier transform infrared spectroscopy and energy-dispersive X-ray spectroscopy techniques were used to study the effect of bone sites and sex to mineral and matrix content and composition. The results show that in rats, all inorganic phases consist of poorly crystalline B-type carbonated apatite, while overall mineralization and carbonate content is virtually unaffected among samples. Statistically significant differences were detected for the nonapatitic environments of acid phosphate and carbonate content. The mean values for the Ca/P ratio point to an increasing trend from tibia to forearm, and to femoral sections.

2019 ◽  
Vol 70 (8) ◽  
pp. 2747-2752
Author(s):  
Constantin Marutoiu ◽  
Ioan Bratu ◽  
Mircea Gelu Buta ◽  
Olivia Florena Nemes ◽  
Sergiu Petru Timbus(Monk Siluan) ◽  
...  

A two-sided wooden icon from a monastery in Transylvania was submitted for multidisciplinary investigations involving X-Ray Fluorescence, Radiographic Photographyand Fourier Transform Infrared Spectroscopy. The most important part of the icon is St. Nicholas wooden icon, painted over forty years ago. The spectroscopic methods used revealed the painting materials composition, the status of the wooden stage, and the presence of resins as varnish (Fourier Transform Infrared Spectroscopy). On one side, the St Nicholasicon was painted over an old icon, St. Arch. Michael, which was evidenced by X-Ray Photography. The obtained data can serve for the preservation and the restoration of these wooden icons.


Catalysts ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 116
Author(s):  
Gian Luca Chiarello ◽  
Ye Lu ◽  
Miren Agote-Arán ◽  
Riccardo Pellegrini ◽  
Davide Ferri

Infrared spectroscopy is typically not used to establish the oxidation state of metal-based catalysts. In this work, we show that the baseline of spectra collected in diffuse reflectance mode of a series of Pd/Al2O3 samples of increasing Pd content varies significantly and reversibly under alternate pulses of CO or H2 and O2. Moreover, these baseline changes are proportional to the Pd content in Pd/Al2O3 samples exhibiting comparable Pd particle size. Similar measurements by X-ray absorption spectroscopy on a different 2 wt.% Pd/Al2O3 confirm that the baseline changes reflect the reversible reduction-oxidation of Pd. Hence, we demonstrate that changes in oxidation state of metal-based catalysts can be determined using diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and that this behavior is part of the spectral changes that are returned by experiments under operando conditions.


2021 ◽  
pp. 152808372110592
Author(s):  
Vahid Shakeri Siavashani ◽  
Gursoy Nevin ◽  
Majid Montazer ◽  
Pelin Altay

Flexible sensors and wearable electronics have become important in recent years. A good conductive and flexible textile is needed to develop a commercial wearable device. Conductive polymers have generally been used with limitation in reducing the surface resistance to a certain amount. In this research, a method for fabricating a stretchable highly conductive cotton/lycra knitted fabric is introduced by treating the fabric with polypyrrole (PPy), silver nanoparticles (SNPs) composites, and post-treating with poly (3,4-ethylenedioxythiophene) poly (styrenesulfonate) (PEDOT:PSS). Polypyrrole and SNPs were in situ fabricated on the cotton/lycra fabric by consecutive redox reaction of silver nitrate and pyrrole and finally covered by PEDOT:PSS solution through dip-coating. The coated textile was characterized by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), X-ray mapping, and energy dispersive X-ray spectroscopy (EDX). Fourier transform infrared spectroscopy confirmed PPy-SNPs (P-S) composites on the fabric surface. Fourier transform infrared spectroscopy results, X-ray mapping, EDAX, and XRD analysis also confirmed the P-S composites and PEDOT:PSS polymeric layer on the fabric. Morphological observation showed a layer of PEDOT:PSS on the P-S caused the higher connection of coating on textiles which resulted in the higher electrical conductivity (43 s/m). Also morphological observations showed penetration of the silver particles inside fibers which represented improving in attachment and stability of the coating on the fibers. Further, the electrical conductivity of PPy-SNPs-PEDOT:PSS coated textile increased under the tension. Hence, the stretchable and highly conductive knitted cotton/lycra fabric has potentiality to be used for fabricating the flexible sensors or wearable electronics.


2017 ◽  
Vol 16 (3) ◽  
pp. 258-264
Author(s):  
Upendra Kumar Giri ◽  
Anirudh Pradhan

AbstractObjectiveThis study was conducted for establishing inherent uncertainty in the shift determination by X-ray volumetric imaging (XVI) and calculating margins due to this inherent uncertainty using van Herk formula.Material and methodsThe study was performed on the XVI which was cone-beam computed tomography integrated with the Elekta AxesseTM linear accelerator machine having six degree of freedom enabled HexaPOD couch. Penta-Guide phantom was used for inherent translational and rotational shift determination by repeated imaging. The process was repeated 20 times a day without moving the phantom for 30 consecutive working days. The measured shifts were used for margins calculation using van Herk formula.ResultsThe mean standard deviations were calculated as 0·05, 0·05, 0·06 mm in the three translational (x, y and z) and 0·05°, 0·05°, 0·05° in the three rotational axes (about x, y, z). Paired sample t-test was performed between the mean values of translational shifts (x, y, z) and rotational shifts. The systematic errors were found to be 0·03, 0·04 and 0·03 mm while the random errors were 0·05, 0·06 and 0·06 mm in the lateral, cranio-caudal and anterio-posterior directions, respectively. For the rotational shifts, the systematic errors were 0·02, 0·03 and 0·03 and the random errors were 0·06, 0·05 and 0·05 in the pitch, roll and yaw directions, respectively.ConclusionOur study concluded that there was an inherent uncertainty associated with the XVI tools, on the basis of these six-dimensional shifts, margins were calculated and recorded as a baseline for the quality assurance (QA) programme for XVI imaging tools by checking its reproducibility once in a year or after any major maintenance in hardware or upgradation in software. Although the shift determined was of the order of submillimetre order, still that shift had great significance for the image quality control of the XVI tools. Every departments practicing quality radiotherapy with such imaging tools should establish their own baseline value of inherent shifts and margins during the commissioning and must use an important QA protocol for the tools.


Author(s):  
S. J. Pradeeba ◽  
K. Sampath

This research was carried out based on the significance of protecting the environment by preventing the contamination of water caused from effluents discharge from dyeing industries, effective nanocomposite were prepared to solve this problem. The poly(azomethine), ZnO, and poly(azomethine)/ZnO nanocomposites were prepared and characterized by Fourier transform-infrared spectroscopy, ultraviolet (UV)–visible spectroscopy, powder X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDAX), scanning electron Microscope (SEM), and transmission electron microscopy (TEM) techniques. Methylene blue (MB), Malachite green (MG), and Bismarck brown (BB) were degraded from water using poly(azomethine) (PAZ), zinc oxide (ZnO), PAZ/ZnO (PNZ) nanocomposites as photocatalyst in the presence of natural sunlight. The degradation efficiency and reaction kinetics were calculated, and the outcome of the photocatalytic experiments proved that the PAZ/ZnO nanocomposites reveals excellent photocatalytic activity and effective for decolorization of dye containing waste water than PAZ and ZnO in the presence of natural sunlight. The maximum degradation efficiency 97%, 96%, and 95% was obtained for PNZ nanocomposites at optimum dosage of catalyst as 500 mg and 50 ppm of MB, MG, and BB dye concentration, respectively. The maximum degradation time was 5 h. After photocatalytic study, the samples were characterized by Fourier-transform infrared spectroscopy (FT-IR) and UV–visible spectroscopy.


2012 ◽  
Vol 476-478 ◽  
pp. 2059-2062
Author(s):  
Chen Wang ◽  
Ya Dong Li ◽  
Gu Qiao Ding

Tributyl borate was first adopted for the introduction of boron in the preparation of bioactive borosilicate xerogel by sol-gel method. The xerogel reacted continuously in 0.25M K2HPO4 solution with a starting pH value of 7.0 at 37 °C for 1day. The structural, morphologies and compositional changes resulting from the conversion were characterized using X-ray diffraction, scanning electron microscopy and Fourier transform infrared spectroscopy. The results indicated that speed of formation of HA was cut way back on the time with the addition of boron and the induction period for the HA nucleation on the surface of the borosilicate xerogel was short than 1 days. The conversion mechanism of the borosilicate xerogels to hydroxyapaptite was also discussed.


Sign in / Sign up

Export Citation Format

Share Document