Responsivity of Fluxgate Sensing Element Under Different Excitation Conditions

Author(s):  
Mohamed Elkattan ◽  
Hassan Mostafa ◽  
A. H. Khalil
Author(s):  
P.-F. Staub ◽  
C. Bonnelle ◽  
F. Vergand ◽  
P. Jonnard

Characterizing dimensionally and chemically nanometric structures such as surface segregation or interface phases can be performed efficiently using electron probe (EP) techniques at very low excitation conditions, i.e. using small incident energies (0.5<E0<5 keV) and low incident overvoltages (1<U0<1.7). In such extreme conditions, classical analytical EP models are generally pushed to their validity limits in terms of accuracy and physical consistency, and Monte-Carlo simulations are not convenient solutions as routine tools, because of their cost in computing time. In this context, we have developed an intermediate procedure, called IntriX, in which the ionization depth distributions Φ(ρz) are numerically reconstructed by integration of basic macroscopic physical parameters describing the electron beam/matter interaction, all of them being available under pre-established analytical forms. IntriX’s procedure consists in dividing the ionization depth distribution into three separate contributions:


1991 ◽  
Vol 148 ◽  
pp. 415-420 ◽  
Author(s):  
R. S. Booth ◽  
Th. De Graauw

In this short review we describe recent new observations of millimetre transitions of molecules in selected regions of the Magellanic Clouds. The observations were made using the Swedish-ESO Submillimetre Telescope, SEST, (Booth et al. 1989), the relatively high resolution of which facilitates, for the first time, observations of individual giant molecular clouds in the Magellanic Clouds. We have mapped the distribution of the emission from the two lowest rotational transitions of 12CO and 13CO and hence have derived excitation conditions for the molecule. In addition, we have observed several well-known interstellar molecules in the same regions, thus doubling the number of known molecules in the Large Magellanic Cloud (LMC). The fact that all the observations have been made under controlled conditions with the same telescope enables a reasonable intercomparison of the molecular column densities. In particular, we are able to observe the relative abundances among the different isotopically substituted species of CO.


Author(s):  
D. Josephine Selvarani Ruth

AbstractNickel Titanium Naval Ordinance Laboratory (NiTiNOL) is widely called as a shape memory alloy (SMA), a class of nonlinear smart material inherited with the functionally programmed property of varying electrical resistance during the transformation enabling to be positioned as a sensing element. The major challenge to instrument the SMA wires is to suppress the wires’ nonlinearity by proper selection of two important factors. The first factor is influenced by the mechanical biasing element and the other is to identify the sensing current for the sensing device (SMA wires + biasing). This paper focuses on developing SMA wires for sensing in different orientation types and configurations by removing the non-linearity in the system’s output by introducing inverse hysteresis to the wires through the passive mechanical element.


Micromachines ◽  
2020 ◽  
Vol 12 (1) ◽  
pp. 10
Author(s):  
Alexander Kukaev ◽  
Dmitry Lukyanov ◽  
Denis Mikhailenko ◽  
Daniil Safronov ◽  
Sergey Shevchenko ◽  
...  

Originally, sensors based on surface acoustic waves are fabricated using photolithography, which becomes extremely expensive when a small series or even single elements are needed for the research. A laser thin film local evaporation technique is proposed to substitute the photolithography process in the production of surface acoustic wave based inertial sensors prototypes. To estimate its potential a prototype of a surface acoustic wave gyroscope sensing element was fabricated and tested. Its was shown that the frequency mismatch is no more than 1%, but dispersion of the wave on small inertial masses leads to a spurious parasitic signal on receiving electrodes. Possible ways of its neglecting is discussed.


2013 ◽  
Vol 647 ◽  
pp. 315-320 ◽  
Author(s):  
Pradeep Kumar Rathore ◽  
Brishbhan Singh Panwar

This paper reports on the design and optimization of current mirror MOSFET embedded pressure sensor. A current mirror circuit with an output current of 1 mA integrated with a pressure sensing n-channel MOSFET has been designed using standard 5 µm CMOS technology. The channel region of the pressure sensing MOSFET forms the flexible diaphragm as well as the strain sensing element. The piezoresistive effect in MOSFET has been exploited for the calculation of strain induced carrier mobility variation. The output transistor of the current mirror forms the active pressure sensing MOSFET which produces a change in its drain current as a result of altered channel mobility under externally applied pressure. COMSOL Multiphysics is utilized for the simulation of pressure sensing structure and Tspice is employed to evaluate the characteristics of the current mirror pressure sensing circuit. Simulation results show that the pressure sensor has a sensitivity of 10.01 mV/MPa. The sensing structure has been optimized through simulation for enhancing the sensor sensitivity to 276.65 mV/MPa. These CMOS-MEMS based pressure sensors integrated with signal processing circuitry on the same chip can be used for healthcare and biomedical applications.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4895
Author(s):  
Thanh-Vinh Nguyen ◽  
Masaaki Ichiki

This paper reports on a mask-type sensor for simultaneous pulse wave and respiration measurements and eye blink detection that uses only one sensing element. In the proposed sensor, a flexible air bag-shaped chamber whose inner pressure change can be measured by a microelectromechanical system-based piezoresistive cantilever was used as the sensing element. The air bag-shaped chamber is fabricated by wrapping a sponge pad with plastic film and polyimide tape. The polyimide tape has a hole to which the substrate with the piezoresistive cantilever adheres. By attaching the sensor device to a mask where it contacts the nose of the subject, the sensor can detect the pulses and eye blinks of the subject by detecting the vibration and displacement of the nose skin caused by these physiological parameters. Moreover, the respiration of the subject causes pressure changes in the space between the mask and the face of the subject as well as slight vibrations of the mask. Therefore, information about the respiration of the subject can be extracted from the sensor signal using either the low-frequency component (<1 Hz) or the high-frequency component (>100 Hz). This paper describes the sensor fabrication and provides demonstrations of the pulse wave and respiration measurements as well as eye blink detection using the fabricated sensor.


Biomolecules ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 759
Author(s):  
Xiaolan Huang ◽  
Rongmei Qu ◽  
Yan Peng ◽  
Yuchao Yang ◽  
Tingyu Fan ◽  
...  

Human skin fibroblasts (HSFs) approximate the multidirectional differentiation potential of mesenchymal stem cells, so they are often used in differentiation, cell cultures, and injury repair. They are an important seed source in the field of bone tissue engineering. However, there are a few studies describing the mechanism of osteogenic differentiation of HSFs. Here, osteogenic induction medium was used to induce fibroblasts to differentiate into osteoblasts, and the role of the mechanical sensitive element PDLIM5 in microfilament-mediated osteogenic differentiation of human fibroblasts was evaluated. The depolymerization of microfilaments inhibited the expression of osteogenesis-related proteins and alkaline phosphatase activity of HSFs, while the polymerization of microfilaments enhanced the osteogenic differentiation of HSFs. The evaluation of potential protein molecules affecting changes in microfilaments showed that during the osteogenic differentiation of HSFs, the expression of PDLIM5 increased with increasing induction time, and decreased under the state of microfilament depolymerization. Lentivirus-mediated PDLIM5 knockdown by shRNA weakened the osteogenic differentiation ability of HSFs and inhibited the expression and morphological changes of microfilament protein. The inhibitory effect of knocking down PDLIM5 on HSF osteogenic differentiation was reversed by a microfilament stabilizer. Taken together, these data suggest that PDLIM5 can mediate the osteogenic differentiation of fibroblasts by affecting the formation and polymerization of microfilaments.


Sign in / Sign up

Export Citation Format

Share Document